PubMed Health⌕ Search

Biomedical subjects

Z Hantos

Publications and source records attributed to Z Hantos.

At least 19 recordsLinked to original sources

Crackle-sound recording to monitor airway closure and recruitment in ventilated pigs.

It was hypothesised that the recruitment of atelectatic lung areas is signified by changes in the airway and tissue mechanics, and by the appearance of crackle activity attributed to the sudden reopening of collapsed airways. The authors also assumed that the acoustic activity is an earlier indicator of lung recruitment than the change in the overall mechanical state of the lungs. Six thoracotomised and mechanically ventilated mini-pigs were studied. Low-frequency pulmonary impedance was measured at end-expiratory pauses at transpulmonary pressures of 4 and 1 hPa to estimate airway resistance (Raw) and the coefficient of lung tissue elastance (H), and tracheal sounds were recorded during subsequent slow inflations to 30 hPa, in the control state and following increasing doses of i.v. methacholine (Mch). Raw and H were higher at baseline and increased more in response to Mch at 1 hPa than at 4 hPa. The crackles detected during the subsequent inflations were concentrated around and associated with the development of the lower knee of the pressure-volume curve. The number of crackles increased faster following the Mch doses and reached statistical significance earlier than Raw and H. Crackle recording during mechanical ventilation can be employed as a simple method with which to monitor lung recruitment-derecruitment.

Airway Obstruction↗

Acoustic evidence of airway opening during recruitment in excised dog lungs.

The aim of this study was to test the hypothesis that the mechanism of recruitment and the lower knee of the pressure-volume curve in the normal lung are primarily determined by airway reopenings via avalanches rather than simple alveolar recruitments. In isolated dog lung lobes, the pressure-volume loops were measured, and crackle sounds were recorded intrabronchially during both the first inflation from the collapsed state to total lobe capacity and a second inflation without prior degassing. The inflation flow contained transients that were accompanied by a series of crackles. Discrete volume increments were estimated from the flow transients, and the energy levels of the corresponding crackles were calculated from the sound recordings. Crackles were concentrated in the early phase of inflation, with the cumulative energy exceeding 90% of its final value by the lower knee of the pressure-volume curve. The values of volume increments were correlated with crackle energy during the flow transient for both the first and the second inflations (r(2) = 0.29-0.73 and 0.68-0.82, respectively). Because the distribution of volume increments followed a power law, the correlation between crackle energy and discrete volume increments suggests that an avalanche-like airway opening process governs the recruitment of collapsed normal lungs.

Animals↗

Preoperative pulmonary hemodynamics determines changes in airway and tissue mechanics following surgical repair of congenital heart diseases.

To characterize the effect of changes in pulmonary hemodynamics on airway and tissue mechanics, forced oscillatory input impedance of the respiratory system (Zrs) was measured between 0.4-12 Hz in two groups of children undergoing surgical repair of congenital heart disease (CHD) immediately before sternotomy and after chest closure during short apneic intervals. Children with lesions associated with high pulmonary blood flow and/or pressure (septal defects; HP group, n = 12) and children with hypoperfused lungs (tetralogy of Fallot; LP group, n = 12) were included in the study. Airway resistance (Raw), and coefficients of respiratory tissue damping (G) and elastance (H), were estimated from Zrs by model-fitting. A postoperative reduction in pulmonary blood flow and/or pressure in the HP group resulted in an immediate decrease in Raw of 29 +/- 9 (SE)% (P < 0.05), whereas children in the LP group had increases in Raw (24 +/- 17%, no significance) after surgery. No significant change was observed in G in either the HP (6.4 +/- 13%) or LP (27 +/- 23%) group, while H increased in children of both the HP (23 +/- 8%, P < 0.05) and LP (36 +/- 7%, P < 0.01) groups. These results suggest that the preoperative pulmonary hemodynamic condition determines changes in airway mechanics: surgical repair of CHD leads to an improvement in airway function only in children with congested lungs. The adverse effects of surgery, mechanical ventilation, and/or cardiopulmonary bypass may be responsible for the increased stiffness of the respiratory system observed in both groups of children.

Airway Resistance↗

The forced oscillation technique in clinical practice: methodology, recommendations and future developments.

The forced oscillation technique (FOT) is a noninvasive method with which to measure respiratory mechanics. FOT employs small-amplitude pressure oscillations superimposed on the normal breathing and therefore has the advantage over conventional lung function techniques that it does not require the performance of respiratory manoeuvres. The present European Respiratory Society Task Force Report describes the basic principle of the technique and gives guidelines for the application and interpretation of FOT as a routine lung function test in the clinical setting, for both adult and paediatric populations. FOT data, especially those measured at the lower frequencies, are sensitive to airway obstruction, but do not discriminate between obstructive and restrictive lung disorders. There is no consensus regarding the sensitivity of FOT for bronchodilation testing in adults. Values of respiratory resistance have proved sensitive to bronchodilation in children, although the reported cutoff levels remain to be confirmed in future studies. Forced oscillation technique is a reliable method in the assessment of bronchial hyperresponsiveness in adults and children. Moreover, in contrast with spirometry where a deep inspiration is needed, forced oscillation technique does not modify the airway smooth muscle tone. Forced oscillation technique has been shown to be as sensitive as spirometry in detecting impairments of lung function due to smoking or exposure to occupational hazards. Together with the minimal requirement for the subject's cooperation, this makes forced oscillation technique an ideal lung function test for epidemiological and field studies. Novel applications of forced oscillation technique in the clinical setting include the monitoring of respiratory mechanics during mechanical ventilation and sleep.

Adolescent↗

Contribution of nasal pathways to low frequency respiratory impedance in infants.

BACKGROUND: In infants the impedance of the nasal pathways (Zn) is a significant proportion of the total respiratory impedance (Zrs). METHODS: In 11 infants Zrs was partitioned into Zn and lower respiratory system impedance (Zlrs) using a nasal catheter. A low frequency oscillatory signal (0.5-20 Hz) was applied during a pause in breathing to obtain the impedance spectra. A model of the respiratory system containing an airway and tissue compartment was then fitted to Zrs and Zlrs. The airway compartment consisted of a frequency independent resistance (R) and inertance (I), while the tissue compartment was described by coefficients of tissue damping (G) and elastance (H). RESULTS: Zrs could be reliably partitioned into Zn and Zlrs. The nasal pathway acted as a purely resistive-inertive impedance and contributed approximately half of the airway resistance (mean (SE) 44.6 (4.9)%) and most of the respiratory system inertance (71.7 (3.5)%). CONCLUSIONS: In studies investigating changes in airway resistance in nasally breathing infants, the separation of nasal and lower respiratory system mechanics will increase the sensitivity of the tests.

Airway Resistance↗

Components of respiratory resistance monitored in mechanically ventilated patients.

The interrupter technique is commonly adopted to monitor respiratory resistance (Rrs,int) during mechanical ventilation; however, Rrs,int is often interpreted as an index of airway resistance (Raw). This study compared the values of Rrs,int provided by a Siemens 940 Lung Mechanics Monitor with total respiratory impedance (Zrs) parameters in 39 patients with normal spirometric parameters, who were undergoing elective coronary bypass surgery. Zrs was determined at the airway opening with pseudorandom oscillations of 0.2-6 Hz at end inspiration. Raw and tissue resistance (Rti) were derived from the Zrs data by model fitting; Rti and total resistance (Rrs,osc=Raw+Rti) were calculated at the actual respirator frequencies. Lower airway resistance (Rawl) was estimated by measuring tracheal pressure. Although good agreement was obtained between Rrs,osc and Rrs,int, with a ratio of 1.07+/-0.19 (mean+/-SD), they correlated poorly (r2=0.36). Rti and the equipment component of Raw accounted for most of Rrs,osc (39.8+/-11.9 and 43.0+/-6.9%, respectively), whereas only a small portion belonged to Rawl (17.2+/-6.3%). It is concluded that respiratory resistance may become very insensitive to changes in lower airway resistance and therefore, inappropriate for following alterations in airway tone during mechanical ventilation, especially in patients with relatively normal respiratory mechanics, where the tissue and equipment resistances represent the vast majority of the total resistance.

Airway Resistance↗

Altered respiratory tissue mechanics in asymptomatic wheezy infants.

Low-frequency forced oscillation (LFOT) and raised volume rapid thoracic compression (RVRTC) techniques were used to measure airways and respiratory tissue mechanics and forced expiratory volumes in 24 asymptomatic infants with recurrent wheeze. Total respiratory impedance spectra (Zrs) (0.5 to 20 Hz) were obtained (n = 22) and a model containing airway (resistance [Raw] and inertance [Iaw]) and constant-phase tissue (tissue damping [G] and tissue elastance [H]) compartments fitted to Zrs. Forced expiratory volumes (FEV(0.5)) were determined (n = 16). Standardized variants (Z scores) were calculated for comparison to a healthy population (Hall et al., Am J Respir Crit Care Med 2000;162:1397-1402). Wheezy infants had elevated H (Z scores: 0.61 +/- 0.20; p = 0.007) but not Raw (0.14 +/- 0.25; p > 0.2), G (0.41 +/- 0.21; p = 0.066), or FEV(0.5) (-0.25 +/- 0.25; p > 0.2) compared with healthy infants. Infants younger than 1 yr of age were not significantly different from normals, whereas lung function from infants older than 1 yr had deviated from normal infants, with Z scores of 0.58 +/- 0.2 (p = 0.018), 0.79 +/- 0.31 (p = 0.032), 1.06 +/- 0.25 (p = 0.002), and -0.94 +/- 0.22 (p = 0.007) for Raw, G, H, and FEV(0.5) respectively. We conclude that asymptomatic infants with recurrent wheeze have altered lung function. The abnormalities were more pronounced in respiratory tissue mechanics than in airway mechanics or forced volumes, highlighting the value of techniques capable of partitioning lung function into airway and respiratory tissue components.

Child, Preschool↗

Characterization of the branching structure of the lung from "macroscopic" pressure-volume measurements.

We analyze the problem of fluid flow in a bifurcating structure containing random blockages that can be removed by fluid pressure. We introduce an asymmetric tree model and find that the predicted pressure-volume relation is connected to the distribution Pi(n) of the generation number n of the tree's terminal segments. We use this relation to explore the branching structure of the lung by analyzing experimental pressure-volume data from dog lungs. The Pi(n) extracted from the data using the model agrees well with experimental data on the branching structure. We can thus obtain information about the asymmetric structure of the lung from macroscopic, noninvasive pressure-volume measurements.

Animals↗

Protective effects of volatile agents against methacholine-induced bronchoconstriction in rats.

BACKGROUND: The protective properties of common volatile agents against generalized lung constriction have previously been addressed only via estimations of parameters that combine airway and tissue mechanics. Their effectiveness in preventing airway constriction have not been compared systematically. Therefore, the authors investigated the abilities of halothane, isoflurane, sevoflurane, and desflurane to provide protection against airway constriction induced by methacholine. METHODS: Low-frequency pulmonary impedance data were collected in open-chest rats under baseline conditions and during three consecutive intravenous infusions of methacholine (32 microg x kg(-1) x min(-1)) while the animals were anesthetized with intravenous pentobarbital (control group). Methacholine challenges were performed in four other groups of rats, first during intravenous anesthesia and then repeated during the inhalation of halothane, isoflurane, sevoflurane, or desflurane at concentrations of 1 and 2 minimum alveolar concentration (MAC). Airway resistance and inertance, parenchymal damping, and elastance were estimated from the impedance data by model fitting. RESULTS: The methacholine-induced increases in airway resistance during intravenous pentobarbital anesthesia (204 +/- 53%) were markedly and significantly (P < 0.005) reduced by 1-MAC doses of halothane (80 +/- 48%), isoflurane (112 +/- 59%), sevoflurane (68 +/- 34%), and desflurane (96 +/- 34%), with no significant difference between the gases applied. Increasing the concentration to 2 MAC did not lead to any significant further protection against the increase in airway resistance. CONCLUSIONS: These data demonstrate that isoflurane, sevoflurane, and desflurane are as effective as the widely accepted halothane in protecting against methacholine-induced airway constriction.

Anesthetics, Inhalation↗

Methacholine responsiveness in infants assessed with low frequency forced oscillation and forced expiration techniques.

BACKGROUND: The contribution of the pulmonary tissues to the mechanical behaviour of the respiratory system is well recognised. This study was undertaken to detect airway and lung tissue responses to inhaled methacholine (Mch) using the low frequency forced oscillation technique (LFOT). METHODS: The respiratory system impedance (Zrs, 0.5-20 Hz) was determined in 17 asymptomatic infants. A model containing airway resistance (Raw) and inertance (Iaw) and a constant phase tissue damping (G) and elastance (H) was fitted to Zrs data. Tissue hysteresivity (eta) was calculated as eta=G/H. The raised volume rapid thoracic compression technique (RVRTC) was used to generate forced expiratory volume in 0.5 seconds (FEV(0.5)). Lung function was determined at baseline and following inhaled Mch in doubling doses (0.25-16 mg/ml) until the maximal dose was reached or a fall of 15% in FEV(0.5) was achieved (PC(15)FEV(0.5)). The response to Mch was defined in terms of the concentration of Mch provoking a change in lung function parameters of more than two standard deviation units (threshold concentration). RESULTS: At PC(15)FEV(0.5) a response in Raw, Iaw, G, and eta, but not H, was detected (mean (SE) 61.28 (12.22)%, 95.43 (34.31)%, 46.28 (22.36)%, 44.26 (25.83)%, and -6.48 (4.94)%, respectively). No significant differences were found between threshold concentrations of LFOT parameters and FEV(0.5). CONCLUSIONS: Inhaled Mch alters both airway and respiratory tissue mechanics in infants.

Bronchoconstrictor Agents↗

Hyperoxia-induced changes in mouse lung mechanics: forced oscillations vs. barometric plethysmography.

Hyperoxia-induced lung damage was investigated via airway and respiratory tissue mechanics measurements with low-frequency forced oscillations (LFOT) and analysis of spontaneous breathing indexes by barometric whole body plethysmography (WBP). WBP was performed in the unrestrained awake mice kept in room air (n = 12) or in 100% oxygen for 24 (n = 9), 48 (n = 8), or 60 (n = 9) h, and the indexes, including enhanced pause (Penh) and peak inspiratory and expiratory flows, were determined. The mice were then anesthetized, paralyzed, and mechanically ventilated. Airway resistance, respiratory system resistance at breathing frequency, and tissue damping and elastance were identified from the LFOT impedance data by model fitting. The monotonous decrease in airway resistance during hyperoxia correlated best with the increasing peak expiratory flow. Respiratory system resistance and tissue damping and elastance were unchanged up to 48 h of exposure but were markedly elevated at 60 h, with associated decreases in peak inspiratory flow. Penh was increased at 24 h and sharply elevated at 60 h. These results indicate no adverse effect of hyperoxia on the airway mechanics in mice, whereas marked parenchymal damage develops by 60 h. The inconsistent relationships between LFOT parameters and WBP indexes suggest that the changes in the latter reflect alterations in the breathing pattern rather than in the mechanical properties. It is concluded that, in the presence of diffuse lung disease, Penh is inadequate for characterization of the mechanical status of the respiratory system.

Air Pressure↗

Effects of gestation and antenatal steroid on airway and tissue mechanics in newborn lambs.

The aim of this study was to partition airway and parenchymal mechanics in newborn lambs at different gestations and following variable exposure to antenatal maternal betamethasone using the forced oscillation technique (FOT). Pulmonary impedance data were collected in 37 sedated and intubated apneic lambs with the FOT between 0.5 and 20 Hz and fitted by a model to estimate airway resistance (Raw) and inertance (Iaw) and the coefficients of tissue resistance (GL) and elastance (HL). Total respiratory resistance (Rrs) was also determined during tidal ventilation by using the multiple linear regression technique. Advancing gestation or increasing antenatal steroid exposure had no clinically significant effect on the values of Raw and Iaw, whereas Rrs and both GL and HL decreased markedly. There was a decrease in tissue hysteresivity (GL/HL) with repeated antenatal steroid exposure. Partitioning of lung mechanics highlights the dominant contribution of the tissues to the total respiratory resistance in the immature ovine lung. Clinically relevant changes in lung mechanics associated with structural and functional maturation of the immature ovine lung are primarily confined to the tissue compartment.

Administration, Topical↗

Endothelin-1-induced airway and parenchymal mechanical responses in guinea-pigs: the roles of ETA and ETB receptors.

Endothelin-1 (ET-1) has been shown to have a constrictor effect on the airways and parenchyma; however, the roles of the ETA and ETB receptors in the ET-1-induced changes in the airway and tissue compartments have not been fully explored. Low-frequency pulmonary impedance (ZL) was measured in anaesthetized, paralysed, open-chest guinea-pigs. ZL spectra were fitted by a model to estimate airway resistance (Raw) and inertance (Iaw), and coefficients of tissue damping (G) and elastance (H), and hysteresivity (eta = G/H). Two successive doses of ET-1 (0.05 and 0.2 nmol x kg(-1)) each evoked significant dose-related increases in Raw, G, H and eta. Pretreatment with 20 nmol x kg(-1) BQ-610 (a highly selective ETA receptor antagonist) resulted in a significantly decreased elevation only in H after the lower dose of ET-1. However, all parameters changed significantly less on the administration of ET-1 after pretreatment with 80 nmol-kg(-1) BQ-610, with 20 nmol x kg(-1) ETR-P1/fl (a novel ETA receptor antagonist) or with 20 nmol x kg(-1) IRL 1038 (an ETB receptor antagonist). The results of the separate assessments of the airway and tissue mechanics demonstrate that endothelin-1 induces airway and parenchymal constriction via stimulation of both receptor types in both compartments.

Airway Resistance↗

Size distribution of recruited alveolar volumes in airway reopening.

In 11 isolated dog lung lobes, we studied the size distribution of recruited alveolar volumes that become available for gas exchange during inflation from the collapsed state. Three catheters were wedged into 2-mm-diameter airways at total lung capacity. Small-amplitude pseudorandom pressure oscillations between 1 and 47 Hz were led into the catheters, and the input impedances of the regions subtended by the catheters were continuously recorded using a wave tube technique during inflation from -5 cm H(2)O transpulmonary pressure to total lung capacity. The impedance data were fit with a model to obtain regional tissue elastance (Eti) as a function of inflation. First, Eti was high and decreased in discrete jumps as more groups of alveoli were recruited. By assuming that the number of opened alveoli is inversely proportional to Eti, we calculated from the jumps in Eti the distribution of the discrete increments in the number of opened alveoli. This distribution was in good agreement with model simulations in which airways open in cascade or avalanches. Implications for mechanical ventilation may be found in these results.

Animals↗

Airway and respiratory tissue mechanics in normal infants.

Low-frequency respiratory impedance (Zrs) was measured by applying a forcing signal, between 0.5 and 21 Hz at a transrespiratory pressure of 20 cm H(2)O, in a cross-sectional study of 37 normal infants. A model containing an airway resistance (Raw) and inertance (Iaw) and a tissue damping (G) and elastance (H) was fitted to the individual Zrs. Forced expiratory volume in 0.5 second (FEV(0.5)) was determined using the raised volume rapid thoracic compression technique. Multivariate regression analysis was used to analyze the relationships between the lung function parameters and length. Both airway and tissue parameters showed a decreasing quadratic relationship with increasing length. FEV(0.5) showed an increasing cubic relationship with length. A family history of asthma was found to have a negative effect on Raw, H, and FEV(0.5).

Airway Resistance↗

Effects of endothelin-1 on airway and parenchymal mechanics in guinea-pigs.

The contributions of the airways and the parenchyma to the overall lung mechanical response to endothelin-1 (ET-1) have not been systematically studied. In this investigation, the ET-1 induced changes on lung mechanics in guinea-pigs were separated into airway and parenchymal components. Pulmonary impedance (ZL) data were collected between 0.5 and 21 Hz in six anaesthetized, paralysed, open-chest animals by introducing small-amplitude pseudorandom oscillations into the trachea through a wave tube. ZL was calculated before and following intravenous boluses of ET-1, with doses doubled from 0.125-2 microg x kg of body weight(-1). A model containing an airway resistance (Raw) and inertance (Iaw) and tissue damping (G) and elastance (H) was fitted to the ZL spectra in each condition. Parenchymal hysteresis (eta) was calculated as G/H. After each dose, ET-1 induced significant increases in Raw (at peak response mean+/-SEM: 424+/-129%), G (400+/-80%), H (95+/-22%) and eta (156+/-33%), whereas Iaw decreased following the two highest doses (-291+/-77%). These data suggest that the parenchymal constriction was accompanied by inhomogeneous constriction of the peripheral airways.

Airway Resistance↗

Scaling behavior in crackle sound during lung inflation.

During slow inflation of lung lobes, we measure a sequence of short explosive transient sound waves called "crackles," each consisting of an initial spike followed by ringing. The crackle time series is irregular and intermittent, with the number of spikes of size s following a power law, n(s) proportional, variants(-alpha), with alpha=2.77+/-0.05. We develop a model of crackle wave generation and propagation in a tree structure that combines the avalanchelike opening of airway segments with the wave propagation of crackles in a tree structure. The agreement between experiments and simulations suggests that (i) the irregularities are a consequence of structural heterogeneity in the lung, (ii) the intermittent behavior is due to the avalanchelike opening, and (iii) the scaling is a result of successive attenuations acting on the sound spikes as they propagate through a cascade of bifurcations along the airway tree.

Journal Article↗

Using low-frequency oscillation to detect bronchodilator responsiveness in infants.

The potential of the low-frequency forced oscillation technique (FOT) to measure the response to inhaled salbutamol was studied in 13 infants with a history of recurrent wheeze and nine healthy infants. The input impedance of the respiratory system (Zrs) between 0.5 and 20 Hz was measured at a transrespiratory pressure of 20 cm H2O during a brief Hering-Breuer reflex-induced pause in breathing. Parameters representing the airway resistance (Raw) and inertance (law), and a constant-phase tissue damping (G) and elastance (H) were estimated from the Zrs spectra. Lung function was measured before and after the administration of 500 microg of salbutamol via a small-volume metal spacer. Six of these infants also received a placebo aerosol. A fall in Raw (13% for the entire group) occurred following treatment with salbutamol (p < 0.008) but not placebo. There was no significant difference in the response to salbutamol between the normal infants (7.65% +/- 5.49%) and those with recurrent wheeze (17.58% +/- 8.67%). On grouped data, the fall in G just failed to reach statistical significance (p = 0.05) after correcting the significance level for multiple tests. No significant change occurred in law or H. We conclude that the low-frequency FOT is a suitable methodology for studying bronchodilator responsiveness in infants.

Administration, Inhalation↗