PubMed Health⌕ Search

Biomedical subjects

Z Horóczi

Publications and source records attributed to Z Horóczi.

3 recordsLinked to original sources

[Continuous ultrasound biomicroscopic imaging of accommodative changes in the human ciliary body].

BACKGROUND: Slitlamp observations of the position of the ciliary body behind the iris root are possible only in cases of gross anatomic, and probably also functional, abnormalities. This study was performed to investigate physiological changes of the human ciliary body configuration during accommodation. MATERIAL AND METHODS: We used the 50 MHz ultrasound biomicroscope to measure the ciliary body changes in 5 left eyes of normal subjects during accommodation, while the right eye, wearing corrective spectacles, focussed Snellen letters at a distance of 3 m. For desaccommodation plus lenses were utilized, while negative lenses were applied to blur vision as a stimulus for accommodation. During postprocessing the best images of the video sequence were recalled on a monitor and the profile of the ciliary body was manually drawn on a transparent folder. For interpretation we used a projection system with vector analysis. RESULTS: During accommodation there is a shift of the ciliary body anteriorly toward the scleral spur and in the direction of the lens equator. In 4 out of 5 eyes a contact between the ciliary body and the posterior iris surface could be demonstrated. There was a measurably widening of the anterior chamber angle in 3 out of 5 eyes. CONCLUSIONS: Ultrasoundbiomicroscopy seems to be a way for assessing ciliary body deformation during accommodation. Our results are in accordance with histologic and gonioscopic findings and confirm biomechanical theories of the accommodation process. Further investigations including online digital image processing will be necessary to evaluate accommodation in its complexity.

Accommodation, Ocular↗

[Examination of the orbit using a non-ophthalmologic ultrasound equipment].

Ophthalmic examinations were performed for determining the suitability of seven different types of non-ophthalmic ultrasound equipments for ophthalmological purposes. According to the results, the instruments with probes of 5 MHz or higher frequency are appropriate for certain screening ophthalmological purposes in hospitals where ophthalmic ultrasound instrument is still missing. The possible indications are: approximate estimation of axial eye length for intraocular lens calculation, and visualization of gross intraocular and orbital diseases, such as retinal detachment, tumours, foreign bodies etc. In case of pathological result or in case of axial eye length different from the average value, the high resolution ophthalmological ultrasound examination is mandatory. The modern colour-coded Doppler ultrasound equipments were found suitable for the examination of the circulation of the eye and orbit.

Eye Diseases↗

Changes in the ocular dimensions after trabeculectomy.

Ocular wall dimensions (axial eye length, anterior chamber depth, lens thickness, vitreous length, thickness and volume of the ocular wall) were determined by echobiometry on 10 eyes of 10 patients with glaucoma one day before and four days after trabeculectomy. The results showed significant differences: decreased axial eye length, and increased thickness and volume of the ocular wall were found after trabeculectomy. The observed changes in the ocular dimensions might be due to ocular hypotony and postoperative inflammation. Echographic follow-up of the changes in the ocular wall is a useful monitor to study alteration in eye dimensions after glaucoma surgery.

Aged↗