PubMed Health⌕ Search

Biomedical subjects

Z J Cao

Publications and source records attributed to Z J Cao.

3 recordsLinked to original sources

An analytical reconstruction algorithm for multifocal converging-beam SPECT.

Multifocal converging-beam collimation has been suggested for cardiac SPECT imaging to increase sensitivity over the heart without truncation of the activity distribution in the chest. In this study, an analytical reconstruction algorithm is derived for multifocal fan-beam and multifocal cone-beam tomography. In the algorithm, the projection data are differently weighted and filtered, depending on the distance from the detector. For a given image point, the set of filtered data corresponding to the distance between this point and detector is backprojected to determine the pixel value of the point. Thus, the backprojection is done only once at each projection view. To evaluate the algorithm, simulation studies are performed using a 3D Defrise slab phantom without considering photon attenuation and scatter, detector response, and statistical noise. Reconstructed images demonstrate that reasonable quality can be achieved with a modest focal-length variation rate and with a small radius of rotation. A collimator with a focal length increasing quickly near its centre provides better quality in the image region distant from the central plane of the cone geometry, but produces more severe artifacts at the centre of the reconstructed image, compared to a collimator with an initially slowly varying focal length.

Algorithms↗

Direct cone beam SPECT reconstruction with camera tilt.

A filtered backprojection (FBP) algorithm is derived to perform cone beam (CB) single-photon emission computed tomography (SPECT) reconstruction with camera tilt using circular orbits. This algorithm reconstructs the tilted angle CB projection data directly by incorporating the tilt angle into it. When the tilt angle becomes zero, this algorithm reduces to that of Feldkamp. Experimentally acquired phantom studies using both a two-point source and the three-dimensional Hoffman brain phantom have been performed. The transaxial tilted cone beam brain images and profiles obtained using the new algorithm are compared with those without camera tilt. For those slices which have approximately the same distance from the detector in both tilt and non-tilt set-ups, the two transaxial reconstructions have similar profiles. The two-point source images reconstructed from this new algorithm and the tilted cone beam brain images are also compared with those reconstructed from the existing tilted cone beam algorithm which requires rebinning the projection data. These comparisons demonstrate that the new algorithm, compared with the existing tilted cone beam algorithm, can provide better image contrast and improved image resolution.

Algorithms↗