PubMed Health⌕ Search

Biomedical subjects

Z J Tan

Publications and source records attributed to Z J Tan.

8 recordsLinked to original sources

Union of capillary high-performance liquid chromatography and microcoil nuclear magnetic resonance spectroscopy applied to the separation and identification of terpenoids.

This paper describes the first coupling of a commercial capillary HPLC system with a diode array spectrophotometric detector and a custom-built nuclear magnetic resonance (NMR) flow microprobe. The eluent from a 3-microm diameter C18 HPLC column is linked to a 500 MHz 1H-NMR microcoil probe with an observe volume of 1.1 microl. The separation and structurally-rich detection of a mixture of terpenoids under both isocratic and gradient solvent elution conditions is presented. The lowest limits of detection yet reported for capillary HPLC on-line measurement (i.e., 37 ng for alpha-pinene) are achieved with this system. The complementary nature of diode array and NMR detection allows stopped-flow data collection from analytes which would otherwise go unnoticed in continuous-flow NMR. Moreover, stopped-flow NMR data is presented for the detection of a trace (sub-nmol) impurity in the sample mixture. Since NMR signals degrade and shift during solvent gradients, flow injection analysis studies are conducted with injected solvent plugs differing in mobile phase composition. The NMR signal degradation accompanying these injections is largely due to the variance in chemical shift with the solvent composition rather than to changes in magnetic susceptibility of the solvent. Characterization of such effects enables the development of improved NMR probes for the coupling of capillary HPLC and NMR.

Chromatography, High Pressure Liquid↗

Percolation with long-range correlations for epidemic spreading.

A percolation model with long-range correlations was introduced to investigate the phenomena of epidemic spreading by Monte Carlo simulations. The correlation exponent alpha and pathogenic ratio s correspond to different spreading methods and pathogenicity of variant epidemics. As the correlation changes from a weak one to a strong one, the patterns change from site percolation to Eden cluster when pathogenic ratio s=1, or Leath percolation cluster when s<1. Corresponding to change of patterns, the fractal dimension increases up to space dimension. The critical behavior in epidemic spreading has been examined based on the model. It is found that correlation has a great influence on the threshold of spreading percolation.

Disease Outbreaks↗

[Modulation of GABA-activated currents by oxytocin in rat dorsal root ganglion neurons].

Experiments were performed on freshly isolated dorsal root ganglion (DRG) neurons of rat. GABA(A)-activated currents were recorded using the whole-cell patch clamp technique. The majority of the neurons (48/52, 90.5%) were sensitive to GABA (10( 6)~10( 3) mol/L). Application of oxytocin (OT) induced outward membrane responses in 51.3% (20/39) of the neurons, no apparent responses in 43.6% (17/39) and inward responses in 5.1% (2/39). 10( 12), 10( 11), 10( 10) and 10( 9) mol/L OT increased 10( 4) mol/L GABA-activated currents to 24.1+/-7.6% (n=6), 33.4+/-6.9% (n=9), 40.2+/-6.5% (n=13) and 67.2+/-14.8% (n=5), respectively. After preapplication of OT, the Kd value for GABA(A)-activated currents decreased, while the response obtained at the maximum concentration increased. The results suggest that the enhancement of GABA-activated currents by OT may suppress primary sensory transmission by potentiating pre-synaptic inhibition of GABA.

Animals↗

A microcoil NMR probe for coupling microscale HPLC with on-line NMR spectroscopy.

An HPLC NMR system is presented that integrates a commercial microbore HPLC system using a 0.5-mm column with a 500-MHz proton NMR spectrometer using a custom NMR probe with an observe volume of 1.1 microL and a coil fill factor of 68%. Careful attention to capillary connections and NMR flow cell design allows on-line NMR detection with no significant loss in separation efficiency when compared with a UV chromatogram. HPLC NMR is performed on mixtures of amino acids and small peptides with analyte injection amounts as small as 750 ng; the separations are accomplished in less than 10 min and individual NMR spectra are acquired with 12 s time resolution. Stopped-flow NMR is achieved by diversion of the chromatographic flow after observation of the beginning of the analyte band within the NMR flow cell. Isolation of the compound of interest within the NMR detection cell allows multidimensional experiments to be performed. A stopped-flow COSY spectrum of the peptide Phe-Ala is acquired in 3.5 h with an injected amount of 5 micrograms.

Amino Acids↗

Influence of particle size on diffusion-limited aggregation.

The influence of particle size on diffusion-limited aggregation (DLA) has been investigated by computer simulations. For DLA clusters consisting of two kinds of particles with different sizes, when large particles are in the minority, the patterns of clusters appear asymmetrical and nonuniform, and their fractal dimensions D(f) increase compared with one-component DLA. With increasing size of large particles, D(f) increases. This increase can be attributed to two reasons: one is that large particles become new growth centers; the other is the big masses of large particles. As the concentration ratio x(n) of large particles increases, D(f) will reach a maximum value D(f(m)) and then decrease. When x(n) exceeds a certain value, the morphology and D(f) of the two-component DLA clusters are similar to those of one-component DLA clusters.

Journal Article↗

Molecular imprint polymers as highly selective stationary phases for open tubular liquid chromatography and capillary electrochromatography.

Chiral separations employing molecular imprint polymer (MIP) stationary phases in both open tubular liquid chromatography (OT-LC) and capillary electrochromatography (OT-CEC) are demonstrated. MIPs are highly crosslinked polymers containing spatial and functionality memory of template molecules which provide a higher degree of selectivity when used as stationary phases for chromatographic separations. Thin films of molecular imprinted polymers bonded to the inner walls of 25 microm ID fused-silica capillaries were prepared using an in situ polymerization technique developed in our laboratory that allows the use of conventional fused-silica capillaries with polyimide outer coatings. The success rate in preparing such open tubular columns was about 70%. Methacrylic acid and 2-vinyl pyridine were chosen as functional monomers, and either ethylene dimethacrylate or trimethylol propane trimethacrylate was used as the crosslinker. Toluene was employed as the porogen. Effects of polymerization conditions on column preparation and chromatographic performance were studied. Enantiomeric separations of D- and L-dansyl phenylalanines were achieved in both OT-LC and OT-CEC modes with good selectivity and efficiencies. Both types of separations may be performed on the same column using a single commercial instrument.

Capillary Action↗

Microcomputer system for automatic identification of the Cryptococcus neoformans and its clinical application.

In this study, microcomputer image processing and pattern recognition technology, and the knowledge of morphology and optical characteristics of Cryptococcus neoformans were used for identification of Cryptococcus neoformans. Four groups of mice were lethally infected with standard strain, Wuhan strain, American B-2643 strain and Var. Shanghainesis of the Cryptococcus neoformans. The samples collected included mice brain, lung, kidney, liver, small intestine tissue and were observed under a light microscope. More than 600 images of the fungus were input into a microcomputer. A system of computer for automatic identification of the Cryptococcus neoformans was developed. The technique involved image preprocessing, image segmenting, coding of line-length on the edge, curve fitting, extracting of image feature, building of image library and feature data bank etc.. And then, 768 images of the clinical samples and other fungus samples whose morphological features tend to be confused with Cryptococcus neoformans were input into microcomputer and subjected to automatic identification. The Cryptococcus neoformans was accurately identified within 15 min, and the consistency rate with results of routine culture was 98%.

Animals↗