Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements.

The contact mechanics in ceramic-on-ceramic hip implants are investigated in this study under the microseparation condition where the edge contact occurs between the superolateral rim of the acetabular cup and the femoral head. A three-dimensional finite element model is developed to examine the effect of the microseparation distance between the femoral head and the acetabular cup on the contact area and contact stresses between the bearing surfaces. It is shown that microseparation leads to edge contact and elevated contact stresses, and these are mainly dependent on the magnitude of separation, the radial clearance between the femoral head and the acetabular cup, and the cup inclination angle. For a small microseparation distance (less than the diametrical clearance), the contact occurs within the acetabular cup, and consequently an excellent agreement of the predicted contact pressure distribution is obtained between the present three-dimensional anatomical model and a simple two-dimensional axisymmetric model adopted in a previous study [5]. However, as microsegregation is increased further, edge contact between the superolateral rim and the femoral head occurs. Consequently, the predicted contact pressure is significantly increased. The corresponding contact area resembles closely the stripe wear pattern observed on both clinically retrieved and simulator-tested ceramic femoral heads [8, 9, 11]. Furthermore, introducing a fillet radius of 2.5 mm at the mouth of the acetabular cup is shown to reduce the contact stress due to edge contact, but only under relatively large microseparation distances.

Acetabulum↗

Analysis of contact mechanics in ceramic-on-ceramic hip joint replacements.

The contact mechanics in ceramic-on-ceramic hip implants has been analysed in this study using the finite element method. Only the ideal conditions where the contact occurs within the acetabular cup were considered. It has been shown that the contact pressure distribution and the contact area at the main articulating bearing surfaces depend largely on design parameters such as the radial clearance between the femoral head and the acetabular cup, as well as the thickness of the ceramic insert. For the ceramic-on-ceramic hip implants used in clinics today, with a minimum 5-mm-thick ceramic insert, it has been shown that the radius of the contact area between the femoral head and the acetabular cup is relatively small compared with that of the femoral head and the ceramic insert thickness. Consequently, Hertz contact theory can be used to estimate the contact parameters such as the maximum contact pressure and the contact area.

Ceramics↗

Prediction of lubricating film thickness in UHMWPE hip joint replacements.

An elastohydrodynamic lubrication model developed for a ball-in-socket configuration in a previous studies by the present authors (Jalali-Vahid et al., Thinning films and tribological interfaces, 26th Leeds-Lyon Symposium on Tribology, 2000, pp. 329-339) was applied to analyse the lubrication problem of a typical artificial hip joint replacement, consisting of an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup against a metallic or ceramic femoral head. The cup was assumed to be stationary whilst the ball was assumed to rotate at a steady angular velocity and under a constant load. A wide range of main design parameters were considered. It has been found that the predicted lubricating film thickness increases with a decrease in the radial clearance, an increase in the femoral head radius, an increase in UHMWPE thickness and a decrease in UHMWPE modulus. However, the predicted lubricating film thicknesses are not found to be sufficiently large in relation to the surface roughness of the cup and head to indicate separation of the two articulating surfaces. It should also be noted that if the design features are unable to secure full fluid film lubrication, it may be preferable to select them for minimum wear rather than maximum film thickness. For example, an increase in head radius will enhance the film thickness, but it will also increase the sliding distance and hence wear in mixed or boundary lubrication conditions. Furthermore, it is pointed out that an increase in the predicted lubricant film thickness is usually associated with an increase in the contact area, and this may cause lubricant starvation and stress concentration at the edge of the cup, and adversely affect the tribological performance of the implant. The effect of running-in process on the lubrication in UHMWPE hip joint replacements is also discussed.

Biocompatible Materials↗

Elastohydrodynamic lubrication analysis of ultra-high molecular weight polyethylene hip joint replacements under squeeze-film motion.

Elastohydrodynamic lubrication was analysed under squeeze-film or normal approach motion for artificial hip joint replacements consisting of an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup and a metallic or ceramic femoral head. A simple ball-in-socket configuration was adopted to represent the hip prosthesis for the lubrication analysis. Both the Reynolds equation and the elasticity equations were solved simultaneously for the lubricant film thickness and hydrodynamic pressure distribution as a function of the squeeze-film time was solved using the Newton-Raphson method. The elastic deformation of the UHMWPE cup was calculated by both the finite element method and a simple equation based upon the constrained column model. Good agreement of the predicted film thickness and pressure distribution was found between these two methods. A simple analytical method based upon the Grubin-Ertel-type approximation developed by Higginson in 1978 [1] was also applied to the present squeeze-film lubrication problem. The predicted squeeze-film thickness from this simple method was found to be remarkably close to that from the full numerical solution. The main design parameters were the femoral head radius, the radial clearance between the femoral head and the acetabular cup, and the thickness and elastic modulus for the UHMWPE cup; the effects of these parameters on the squeeze-film thickness generated in current hip prostheses were investigated.

Arthroplasty, Replacement, Hip↗

Importance of pin geometry on pin-on-plate wear testing of hard-on-hard bearing materials for artificial hip joints.

The contact mechanics between the pin and the plate used in simple wear screening tests were investigated in this study. Both soft-on-hard, such as ultra-high molecular weight polyethylene (UHMWPE)-on-metal or UHMWPE-on-ceramic, and hard-on-hard, such as metal-on-metal, bearing couples were considered. The effect of the pin geometry and the misalignment between the pin and the plate were investigated on the predicted contact pressure distribution at the bearing surfaces using the finite element method. It was demonstrated that in the case of soft-on-hard bearing couples, neither the geometrical discontinuity of the pin surface nor the misalignment could cause a significant increase in the contact stress. However, for hard-on-hard combinations, even with a very small misalignment of 0.5 degrees between the pin and the plate, the geometrical discontinuity could lead to a more than tenfold increase in the predicted contact stress. This elevated contact stress may lead to a large scatter in the wear data and, even more importantly, structural damage of the bearing surfaces.

Biomechanical Phenomena↗

Elastohydrodynamic lubrication analysis of metal-on-metal hip prostheses under steady state entraining motion.

The elastohydrodynamic lubrication problem of metal-on-metal hip joint replacements was considered in this study. A simple ball-in-socket configuration was used to represent the hip prosthesis. The Reynolds equation in a spherical coordinate was adopted for the fluid-film lubrication analysis, to account for the ball-in-socket geometry. The corresponding elastic deformation was calculated by means of the finite element method in order to consider the complex ball-in-socket geometry as well as the backing materials underneath the acetabular cup. Both the Reynolds and the elasticity equations were solved simultaneously using the Newton-Raphson finite difference method. The general methodology developed was then applied to a recent experimental prototype metal-on-metal hip implant. It was shown that the backing materials underneath the acetabular cup had little influence on the predicted contact pressure and the elastic deformation at the bearing surfaces for this particular example. Both the film thickness and the hydrodynamic pressure distributions were obtained under various loads up to 2500 N. The predicted minimum lubricating film thickness from the present study was compared with a simple estimation using the Hamrock and Dowson formulae based upon an equivalent ball-on-plane model and excellent agreement was found. However, it was pointed out that for some forms of metal-on-metal hip prostheses with a thin acetabular cup, a polyethylene inlay underneath a metallic bearing insert or a taper connection between a bearing insert and a fixation shell, the general methodology developed in the present study should be used and this will be considered in future studies.

Elasticity↗

Contact mechanics of a novel metal-on-metal total hip replacement.

The contact mechanics of a novel metal-on-metal total hip replacement (THR) were investigated in this study. The metal-on-metal prosthesis considered consists of a cobalt-chrome acetabular insert connected to a titanium shell through a taper contact, articulating against a cobalt-chrome femoral head. Both the experimental measurement of the displacement of the acetabular insert and the contact area between the two bearing surfaces, and the corresponding numerical predictions using the finite element method have been conducted. Excellent agreement has been demonstrated between the experimental measurement and the finite element prediction under various loads up to 3 kN. The maximum contact pressure at the articulating surfaces has been predicted to be about 31 MPa from a simple axisymmetric finite element model, significantly lower than that of a similar cup but with a monoblock construct. This has been mainly attributed to the flexibility of the insert, leading to an increase in the conformity between the femoral head and the acetabular insert. In addition, the predicted maximum contact pressure is only slightly increased to 37 MPa, from a more realistic three-dimensional anatomical finite element model. The design features on metal-on-metal THRs have been shown to reduce contact stresses and may improve tribological performances of these hard-on-hard bearing couples.

Biomechanical Phenomena↗

A general axisymmetric contact mechanics model for layered surfaces, with particular reference to artificial hip joint replacements.

A general axisymmetric contact mechanics model for layered surfaces is considered in this study, with particular reference to artificial hip joint replacements. The indenting surface, which represents the femoral head, was modelled as an elastic solid with or without coating, while the other contacting surface, which represents the acetabular cup, was modelled as a two-layered solid. It is shown that this model is applicable to current total hip joint prostheses employing ultra-high molecular weight polyethylene (UHMWPE) acetabular cups against metallic, metallic with coating or ceramic femoral heads as well as metal-on-metal combinations. The effect of cement is also investigated for these prostheses using this model. The use of a metallic bearing surface bonded to a UHMWPE substrate for acetabular cups is particularly examined for metal-on-metal hip joint replacements. Both the contact radius and the contact pressure distribution are predicted for examples of these total hip joint replacements, under typical conditions. Application of contact mechanics to the design of artificial hip joint replacements employing various material combinations is discussed.

Biomechanical Phenomena↗

Analysis and modelling of wear of cobalt-chrome alloys in a pin-on-plate test for a metal-on-metal total hip replacement.

The complex interaction between wear and bearing surfaces of two contacting solids was investigated in this study, with particular reference to the use of metal-on-metal material combinations for artificial hip joint replacements. The contact mechanics model was coupled with the wear model and solved simultaneously as a function of time for a simple case of a uniaxial pin-on-plate wear test. Both a spherical pin and a flat-ended spherical pin were considered. It was shown that the contact pressure between the pin and the plate was substantially reduced by the wear process, particularly during the initial running-in period and for the spherical pin. The theoretical prediction of the worn profiles of the pin and the plate was found to be in good agreement with previous experimental measurements by Tipper et al. in 1999.

Biocompatible Materials↗

Frictional behaviour of bovine articular cartilage.

The experimentally measured indentation displacement and friction of normal and degraded (treated with chondroitinase AC) bovine articular cartilage plugs against a smooth steel plate were compared with the predictions based on the biphasic theory using the finite element method. It was found that the measured indentation displacement of both cartilage specimens could be predicted from the biphasic theory and the permeability for the degraded cartilage specimen was increased approximately three times. However, the measured friction coefficient was much lower for short period of loading, and the difference in the finite element prediction of friction coefficient between the normal and degraded cartilage specimens was not observed in the experiment. Therefore, it was concluded that both biphasic and other mechanisms were important in controlling the frictional and lubricating characteristics of articular cartilage in mixed and boundary lubrication regimes.

Animals↗

D20S161 data for three ethnic populations and forensic validation.

In order to evaluate the forensic applicability of the STR locus D20S161 and construct a preliminary database, the genotype distributions and allele frequencies in five populations from three main ethnic groups were investigated, including Germans, Slovakians, African Americans, Japanese and Chinese. A total of 512 samples from unrelated individuals and 85 confirmed father/mother/ child triplets were analyzed by PCR and allele determination was carried out by comparison with a sequenced human allelic ladder. The results showed that D20S161 typing was both precise and reliable. A total of 7 alleles was found in these populations and no evidence of deviation from Hardy-Weinberg equilibrium was observed. Pairwise comparisons between populations showed that there were significant differences in the distributions of the allele frequencies among the three main ethnic groups. No mutation events were observed from the confirmed father/mother/child triplets. With a maximum likelihood method, the mutation rate was indirectly estimated as 2.5 x 10(-5). These results suggest that D20S161 is a useful marker for forensic casework and paternity analysis.

Asian People↗

An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements.

Contact mechanics of ultra high molecular weight polyethylene (UHMWPE) cups against metallic femoral heads for artificial hip joints is considered in this study. Both the experimental measurement of the contact area and the finite element prediction of the contact radius, maximum contact pressure and maximum Von Mises stress have been carried out for a wide range of contemporary artificial hip joints. Good agreement of the contact radius has been found between the experimental measurements and the finite element predictions based upon an elastic modulus of 1000 MPa and a Poisson's ratio of 0.4 for UHMWPE material under various loads up to 2.5 kN. It has been shown that the half contact angle for all the cup/head combinations considered in this study is between 40 degrees and 50 degrees under a load of 2.5 kN. The importance of this result has been discussed with respect to the anatomical position of the cup when placed in the body and the selection of a simple wear-screening test for artificial hip joints. The predicted contact radius and maximum contact pressure from the finite element model have also been compared with a simple elasticity analysis. It has been shown that the difference in the predicted contact radius between the two methods is reduced for more conforming contacts between the femoral head and the acetabular cup and smaller UHMWPE cup thickness. However, good agreement of the predicted maximum contact pressure has been found for all the combinations of the femoral head and the acetabular cup considered in this study. The importance of contact mechanics on the clinical performance of artificial hip joint replacements has also been discussed.

Elasticity↗

A comparative tribological study of the wear of composite cushion cups in a physiological hip joint simulator.

A composite cushion acetabular cup for a total hip replacement has been designed and developed jointly by Leeds University and DePuy International. In order to assess the long-term performance of this novel design, two sets of simulator tests of more than 4 million cycles duration have been carried out with the cushion bearings using the Leeds PA hip joint simulator with bovine serum as the lubricant. The results of these simulator tests were compared to the results from a previously reported study that used 32 mm ultrahigh molecular weight polyethylene (UHMWPE) acetabular cups. Under a physiological walking cycle simulation, with continuous cyclic motion and loading, the composite cushion cups produced negligible wear compared to a volumetric wear rate of 32 mm3 per million cycles for the conventional UHMWPE acetabular cups. This study has demonstrated for the first time the beneficial effects of fluid film lubrication in reducing wear in composite cushion acetabular cups.

Animals↗

Analysis of contact mechanics for composite cushion knee joint replacements.

Recent research in the area of cushion form bearings for total joint replacements has primarily used thin, soft, elastomeric layers with similar elastic modulus to articular cartilage, bonded to rigid substrates. These are designed to promote the body's natural lubricants to separate the articulating surfaces and prevent wear. Applications to joint replacements have revealed that the abrupt change in stiffness between the soft layer and the rigid substrate and the relatively low strength of the interface resulted in high shear stresses and debonding of the soft layer from the substrate. The approach adopted in this study is to use components with a graded modulus or composite construction. The composite construction consists of a soft compliant layer of polyurethane and a second stiffer polyurethane layer thought to be rigid enough to mechanically interlock to a metallic tibial tray. In this composite structure the deformation of the more rigid polyurethane underlay may generally influence the stress distribution and deformation in the softer upper layer and at the interface between the two materials. A simple analysis technique is presented in the present study where the composite double layer was approximated as an equivalent modulus single layer. Single layer theory, which is readily available in the literature, can then be used to determine the contact parameters, including the maximum contact pressure and the contact radius, for the composite structure. By varying the layer thicknesses and material properties of both the soft surface layer and the stiffer structural support layer, the magnitudes and locations of stresses can be controlled. Results of a parametric stress analysis are presented to assist in the selection of the most appropriate composite layers for cushion knee designs. A 4 mm thick surface layer with an elastic modulus of 20 MPa and a 4 mm thick structural support layer with an elastic modulus of 1000 MPa were considered suitable for this application.

Biomechanical Phenomena↗

Prediction of transient lubricating film thickness in knee prostheses with compliant layers.

The transient lubricating film thickness in knee prostheses using compliant layers has been predicted under simulated walking conditions based upon the elastohydrodynamic lubrication theory. Qualitative agreement has been found between the present theoretical predictions and the experimental measurements using an electric resistance technique reported earlier. It has been shown that the contact geometry plays an important role in the generation of fluid film lubrication in knee prostheses using compliant layers. The maximum lubricating film thickness is predicted for the maximized contact area of a transverse conjunction where the semi-minor contact radius lies in the direction of entraining. The additional advantage of the transverse contact conjunction is that the possibility of lubricant starvation due to small stroke length can be minimized. All these factors, together with the kinematic requirements in the natural knee joint, should be taken into consideration when designing artificial knee joint replacements.

Biocompatible Materials↗

Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus.

Lubrication mechanisms and contact mechanics have been analysed for total hip joint replacements made from hard bearing surfaces such as metal-on-metal and ceramic-on-ceramic. A similar analysis for ultra-high molecular weight polyethylene (UHMWPE) against a hard bearing surface has also been carried out and used as a reference. The most important factor influencing the predicted lubrication film thickness has been found to be the radial clearance between the ball and the socket. Full fluid film lubrication may be achieved in these hard/hard bearings provided that the surface finish of the bearing surface and the radial clearance are chosen correctly and maintained. Furthermore, there is a close relation between the predicted contact half width and the predicted lubrication film thickness. Therefore, it is important to analyse the contact mechanics in artificial hip joint replacements. Practical considerations of manufacturing these bearing surfaces have also been discussed.

Biocompatible Materials↗

Friction of composite cushion bearings for total knee joint replacements under adverse lubrication conditions.

Conventional joint replacements consist of a polished metallic or ceramic component articulating against a layer of polyethylene. Although the friction in the contact between these articulating surfaces is low, polyethylene wear is produced as a result of a boundary/mixed lubrication regime. Wear debris is generated by direct asperity contact, abrasion, adhesion and fatigue, and has been shown to cause adverse tissue reactions which can lead to joint failure. The introduction of soft compliant materials, similar in stiffness to articular cartilage, has shown that with cyclic loading and relative motion between the articulating surfaces typical of normal walking, a fluid film can be maintained through combined entraining and squeeze-film actions, and hence wear can be minimized. For 95 per cent of the time, however, we are not walking but standing still or moving slowly. A pendulum simulator has been used in the present study to investigate the effect of adverse tribological conditions which may lead to fluid film breakdown, such as severe cyclic loading, particularly in the swing phase, reduced sliding velocity, reduced stroke length and start-up after a period of constant loading. Friction of a model composite cushion knee bearing, manufactured from a graded modulus (20-1000 MPa) layer of polyurethane, sliding against a polished metal cylinder has been measured for various lubricants and the results have been analysed using a Stribeck assessment. Severe cyclic loading, decreased sliding velocity and decreased stroke length have been found to limit the degree of fluid entrainment previously allowed during the swing phase of normal walking, thus allowing breakdown of fluid films and elevated levels of friction and surface damage. Soft layer joint replacements must therefore be designed to operate with thick elastohydrodynamic fluid films to provide some degree of protection when tribological conditions become severe, or alternatively incorporate alternative boundary or mixed lubrication mechanisms. This study quantifies a potential limitation of the cushion bearing concept.

Elasticity↗

Determination of lubricating film thickness for permeable hydrogel and non-permeable polyurethane layers bonded to a rigid substrate with particular reference to cushion form hip joint replacements.

The lubricating film thickness in a model of compliant layered bearings, using both permeable hydrogels and non-permeable polyurethane elastomers for total hip joint replacements, has been measured using optical interferometry, under both entraining and squeeze-film motion. The film thickness in the lubricated contact was measured for both water and a 40 per cent glycerol solution in water as a function of entraining velocity and squeeze-film time. The measured lubricating film thickness for the permeable hydrogel was compared to that of the non-permeable polyurethane elastomer and little difference was found when the lubricating film thickness was sufficiently large (greater than 150 nm). Comparison of the experimental results and the theoretical predictions based upon elastohydrodynamic lubrication analysis showed good agreement in the entraining experiments where the film thickness was greater than 150 nm. In the squeeze-film experiments the experimental measurements were greater than the theoretical predictions for all squeeze times due to the formation of a central pocket of fluid which was not predicted by the simple theory used. This also occurred for the hydrogels for films greater than 150 nm. For longer squeeze times the film thickness for the hydrogel fell below the theoretical prediction. This was considered to be due to the permeability of the hydrogel reducing the film thickness when the film thickness was less than 150 nm. The permeability of the hydrogel was not modelled in the theoretical lubrication analysis used in this study.

Biomechanical Phenomena↗