PubMed Health⌕ Search

Biomedical subjects

Z Ori

Publications and source records attributed to Z Ori.

5 recordsLinked to original sources

Heart rate variability. Frequency domain analysis.

Experience with frequency domain analysis over the past two decades strongly suggests that it represents a unique, noninvasive tool for achieving a more precise assessment of autonomic function in both the experimental and clinical settings. Available studies indicate that the significance of the HF component is far better understood than that of the lower frequency components. In general, it is considered to reflect vagal activity, and because it is readily manipulated pharmacologically, is used as a an index of that activity. However, some caution is required because this parameter also is strongly influenced by the degree of coupling between respiration and heart rate, which, in turn, reflects the intensity of the respiratory effort as well as of parasympathetic activity. Respiratory pattern also can significantly influence HF power. The use of controlled breathing minimizes these problems, improves reproducibility of test findings, and also facilitates quantitative comparisons. The situation with respect to LF power is more complicated because it is modulated by both sympathetic and parasympathetic outflows (see previous discussion) as well as by other factors, including baroreceptor activity. Therefore, LF analysis per se cannot afford a precise delineation of the state of sympathetic activation. Determinations of the LF/HF ratio, an index of sympathovagal balance both under control conditions and in conjunction with interventions that maximize sympathetic and parasympathetic activity, provide additional insights, as do correlations between spectral activity and direct nerve recordings, plasma norepinephrine concentrations, and radionuclide imaging of adrenergic nerves. Renewed interest has recently been evinced in frequencies lower than 0.04 Hz in view of reports that the VLF portion of the spectrum (0.01-0.04 Hz) reflects a purer form of sympathetic activity than does the LF band. Despite the potential applicability to clinical problems, only very little is known about the physiologic basis of the VLF and ULF bands. Further study is required. However, it is important to note that meaningful determinations of VLF and ULF power may be difficult because decreases in frequency to such low levels are associated with an increasing propensity to violate the rules governing power spectral determinations (see previous discussion and appendix), violations that diminish reliability despite the most sophisticated preprocessing. It is also noteworthy that the reliability of spectral power determinations diminishes with decreases in the power of the signal and of the signal-to-noise ratio.(ABSTRACT TRUNCATED AT 400 WORDS)

Aging↗

[The significance of the dipyramidole echocardiography test in ischemic heart disease].

The diagnostic value of the dipyridamole echocardiography test was investigated in 46 patients who underwent coronary angiography due to suspected ischaemic heart disease. Twenty-two of 46 patients were found to have a narrowing of at least 70% one vessel. Twenty-four hour ECG monitoring was also performed on 19 patients on the day of the dipyridamole test. The sensitivity and specificity of the two-dimensional echocardiography test (new wall motion abnormality) were 72.7% and 62.5%. The ECG (V2-5-9) had a low sensitivity during the test (43.8%). Good agreement was found between the localization of the wall motion abnormalities and the site of anatomic narrowing in the ischaemic group. No significant ventricular arrhythmias were detected, and the sensitivity and specificity of ST-T changes were found to be 62.5% and 54.6% by means of Holter monitoring. The dipyridamole echocardiography test proved to be a suitable noninvasive method for the diagnosis of ischaemic heart disease and for the selection of patients for coronary angiography.

Coronary Angiography↗

Diagnostic value of foil thermography in urological diseases.

Authors summarize their experience of 8 years with foil thermography. Based on a total of 1113 examinations, they assess the diagnostic value of this method in some andrological and urological diseases. They found foil thermography to be an independent, but not the exclusive procedure in diagnosing varicocele. In addition, this method has proved to be highly valuable also in differentiating the inflammatory and tumorous processes of the testicles. They point out that thermography is very useful for outpatient practice, due to its inexpensiveness, simplicity and rapid applicability.

Humans↗

Continuous monitoring of gastric movements in rats subjected to restraint.

Gastric motility was recorded continuously by strain gage technique in two groups of animals, subjected to 24 hours' restraint. Ten rats served as control and 10 were pretreated with 100 mg/kg of cimetidine. The electric signals, produced by gastric movements, were recorded by a tape recorder and were then further analysed by a computer. In order to make comparison between the two groups of animals a precise quantitative analysis of gastric movements was performed by using different computer programs. Three parameters of recordings (frequency, size of contractions and area under the waves) have been used to characterize the curves. It was established that there was no essential difference in the two experimental groups concerning the gastric motility pattern. Brisk gastric movements could be recorded during the whole period of restraint. It may be concluded that increased gastric movements may not play an important role in the pathogenesis of stress-induced mucosal lesions and that cimetidine exerts its anti-ulcer effect via other mechanisms than influencing gastric motility.

Animals↗

[Experimental data on the peristaltic activity of the ileal ureter].

A new method by considering the physiological relations by means of strain gauges was explored for the investigation of the peristaltic activity of the ileal ureter. The motility of the ileal ureter can be measured simultaneously with the peristaltic activity of the ileum by this method, and mathematical signal analysis. The ileal ureter has a continuous rhythmic peristalsis. This one differs from the contractions of the ileum above all by the amplitude. The ileal ureter secures the urinary transport under different experimental situations with enlarged amplitude and rhythmic peristalsis.

Animals↗