PubMed Health⌕ Search

Biomedical subjects

Z Sentürk

Publications and source records attributed to Z Sentürk.

10 recordsLinked to original sources

Simultaneous determination of paracetamol and methocarbamol in tablets by ratio spectra derivative spectrophotometry and LC.

The application of the ratio spectra derivative spectrophotometry and high-performance liquid chromatography (HPLC) to the simultaneous determination of paracetamol (PAR) and methocarbamol (MET) in combined pharmaceutical tablets is presented. The spectrophotometric procedure is based on the use of the first derivative of the ratio spectra obtained by dividing the absorbtion spectrum of the binary mixtures by a standard spectrum of one of the compounds. The first derivative amplitudes were measured at 243.0 and 230.3 nm for the assay of PAR and MET, respectively. Calibration graphs were established for 2-30 microg ml for PAR and 2-36 microg/ml for MET in binary mixture. The detection limits for PAR and MET were found 0.097 and 0.079 microg/ml, respectively; while the quantification limits were 0.573 microg/ml for PAR and 1.717 microg/ml for MET. For the HPLC procedure, a reversed-phase column with a mobile phase of methanol-water (60:40, v/v), was used to separate both compounds with a detection of 274.0 nm. Linearity was obtained in the concentration range of 2 300 and 1.5-375 microg/ml for PAR and MET, respectively. The detection and quantification limits were found to be 0.42 and 1.4 microg/ml for PAR and 0.36 and 1.2 microg/ml for MET, respectively. The relative standard deviations were found to be less than 0.52%, indicating reasonable repeatibility of both methods. The proposed methods were successfully applied to the determination of these drugs in commercial tablets.

Acetaminophen↗

Simultaneous determination of valsartan and hydrochlorothiazide in tablets by first-derivative ultraviolet spectrophotometry and LC.

First-derivative ultraviolet spectrophotometry and high-performance liquid chromatography (HPLC) were used to determine valsartan and hydrochlorothiazide simultaneously in combined pharmaceutical dosage forms. The derivative procedure was based on the linear relationship between the drug concentration and the first derivative amplitudes at 270.6 and 335 nm for valsartan and hydrochlorothiazide, respectively. The calibration graphs were linear in the range of 12.0-36.1 microg x ml(-1) for valsartan and 4.0-12.1 microg x ml(-1) for hydrochlorothiazide. Furthermore, a high- performance liquid chromatographic procedure with ultraviolet detection at 225 nm was developed for a comparison method. For the HPLC procedure, a reversed phase column with a mobile phase of 0.02 M phosphate buffer (pH 3.2)-acetonitrile (55: 45; v/v), was used to separate for valsartan and hydrochlorothiazide. The plot of peak area ratio of each drug to the internal standard versus the respective concentrations of valsartan and hydrochlorothiazide were found to be linear in the range of 0.06-1.8 and 0.07-0.5 microg x ml(-1), respectively. The proposed methods were successfully applied to the determination of these drugs in laboratory-prepared mixtures and commercial tablets.

Antihypertensive Agents↗

Simultaneous determination of melatonin and pyridoxine in tablet formulations by differential pulse voltammetry.

A method has been developed for the simultaneous determination of melatonin (MT) and pyridoxine hydrochloride (PY) in pharmaceutical dosage forms by differential pulse voltammetry, based on the oxidation of both drugs at a glassy carbon electrode. Cyclic and linear scan voltammetry were used to examine the influence of pH, nature of the buffer, scan rate and concentration. The results in 0.5 M H2SO4 with 20% methanol allowed a method to be developed for the determination of MT and PY simultaneously and in the presence of each other in the ranges 2 x 10(-5)-8 x 10(-5) and 2 x 10(-5)-4 x 10(-4) M, with the detection limits of 5.86 x 10(-6) and 2.45 x 10(-6) M, respectively. The proposed method was successfully applied to the commercial tablets containing this drug combination without any interference by the excipients.

Antioxidants↗

Voltammetric investigation of oxidation of zuclopenthixol and application to its determination in dosage forms and in drug dissolution studies.

The oxidative voltammetric behaviour of zuclopenthixol (ZPT) at a glassy carbon has been studied using cyclic, linear sweep and differential pulse voltammetry. Oxidation of the drug produced three pH dependent anodic steps (representing an irreversible oxidation). Using differential pulse voltammetry, the drug yielded a well-defined voltammetric response in phosphate buffer, pH 5.2 at + 0.82 V (vs. Ag/AgCl). This process could be used to determine ZPT concentrations in the range 8 x 10(-7)-2 x 10(-4) M. The method was applied, without any interferences from the excipients, to the determination of the drug in tablets and oral drops, and in drug dissolution studies.

Antipsychotic Agents↗

Electroanalytical study of nifedipine using activated glassy carbon electrode.

The electrochemical properties of nifedipine have been investigated in aqueous solution by linear sweep and cyclic voltammetry. The method is based both on the reduction and on the oxidation of the drug at a glassy carbon electrode activated by applying a new pre-treatment. The voltammograms of nifedipine on pH, concentration and scan rate have been carefully examined. Both the electroreduction and electrooxidation of nifedipine allow its determination at pH 1.5 in the concentration range of 2 x 10(-5)-6 x 10(-4) M and 8 x 10(-5)-1 x 10(-3) M, respectively. The method has been applied to commercial samples (tablets and capsules).

Calcium Channel Blockers↗

Electrochemical reduction of metronidazole at activated glassy carbon electrode and its determination in pharmaceutical dosage forms.

A voltammetric method has been developed for the determination of metronidazole in dosage forms. The method is based on the electrochemical reduction of the drug at a glassy carbon electrode activated by applying a new pretreatment. The influence of pH, concentration, scan rate and presence of organic solvent and surfactant has been studied. The current is proportional to the concentration and permits the drug to be determined in the concentration range 2 x 10(-6)-6 x 10(-4) M in Britton-Robinson buffer (pH 10). Furthermore, results obtained by the proposed method have been compared with USP XXIII procedure which involves a HPLC method.

Antitrichomonal Agents↗

Determination of terbutaline based on oxidation by voltammetry.

A voltammetric study of the oxidation of terbutaline has been carried out at an activated glassy carbon electrode. The compound was oxidized irreversibly at high positive potential. The response was evaluated with respect to pH, scan rate, nature of the buffer and other variables. The peak current, at about 0.8 V (versus a saturated calomel electrode), was proportional to the terbutaline concentration in the range of 8 x 10(-6)-8 x 10(-4) M in phosphate buffer pH 6.0. This method was applied, without any interferences from the excipients, to determine the drug in a tablet dosage form.

Adrenergic beta-Agonists↗

Anodic voltammetry of fluphenazine at different solid electrodes.

The electrochemical behaviour of fluphenazine based on its oxidation at platinum and glassy carbon electrodes was investigated by linear sweep and cyclic voltammetry. The influence of pH, concentration, nature of the buffer and scan rate was carefully examined. At both electrodes, three anodic steps (representing an irreversible oxidation) were obtained. The method was applied to the determination of fluphenazine in sugar-coated tablets.

Antipsychotic Agents↗