PubMed Health⌕ Search

Biomedical subjects

Zaccaria Ricci

Publications and source records attributed to Zaccaria Ricci.

At least 19 recordsLinked to original sources

Usefulness of a molecular strategy for the detection of bacterial DNA in patients with severe sepsis undergoing continuous renal replacement therapy.

INTRODUCTION: Sepsis is a major cause of morbidity and mortality in critically ill patients. Sepsis is associated with cell necrosis and apoptosis. Circulating plasma levels of DNA have been found in conditions associated with cell death, including sepsis, pregnancy, stroke, myocardial infarction and trauma. Plasma DNA can also derive from bacteria. We have recently implemented a method to detect bacterial DNA and, in the present study, we validated this technique comparing it to standard blood culture in terms of diagnostic efficacy. METHODS: We examined a cohort of 9 critically ill patients with a diagnosis of severe sepsis and acute renal failure requiring continuous renal replacement therapy (CRRT). We analyzed bacterial DNA in blood, hemofilters, and ultrafiltrate (UF) by polymerase chain reaction amplification of 16S rRNA gene sequence analysis. Standard blood cultures were performed for all patients. RESULTS: The blood cultures from 2 of the 9 (22%) patients were positive. However, bacterial DNA was identified in the blood of 6 patients (67%), including the 2 septic patients with positive blood cultures. In 9 (100%) patients bacterial DNA was found on the filter blood side, whereas in 7 (78%) subjects it was found in the dialysate compartment of the hemofilters. Bacterial DNA was never detected in the UF. CONCLUSIONS: Using the 16S rRNA gene, the detection of bacterial DNA in blood and adsorbed within the filter could be a useful screening tool in clinically septic, blood culture-negative patients undergoing CRRT. However, the identification of the etiologic agent is not feasible with this technique because specific primers for the defined bacteria must be used to further identify the suspected pathogenic organisms.

Acute Kidney Injury↗

Cerebral blood flow during cardiopulmonary bypass in pediatric cardiac surgery: the role of transcranial Doppler--a systematic review of the literature.

BACKGROUND: Transcranial Doppler Ultrasound (TCD) is a sensitive, real time tool for monitoring cerebral blood flow velocity (CBFV). This technique is fast, accurate, reproducible and noninvasive. In the setting of congenital heart surgery, TCD finds application in the evaluation of cerebral blood flow variations during cardiopulmonary bypass (CPB). METHODOLOGY: We performed a search on human studies published on the MEDLINE using the keyword "trans cranial Doppler" crossed with "pediatric cardiac surgery" AND "cardio pulmonary by pass", OR deep hypothermic cardiac arrest", OR "neurological monitoring". DISCUSSION: Current scientific evidence suggests a good correlation between changes in cbral blood flow and mean cerebral artery (MCA) blood flow velocity. The introduction of Doppler technology has allowed an accurate monitorization of cerebral blood flow (CBF) during circulatory arrest and low-flow CPB. TCD has also been utilized in detecting cerebral emboli, improper cannulation or cross clamping of aortic arch vessels. Limitations of TCD routine utilization are represented by the need of a learning curve and some experience by the operators, as well as the need of implementing CBF informations with, for example, data on brain tissue oxygen delivery and consumption. CONCLUSION: In this light, TCD plays an essential role in multimodal neurological monitorization during CPB (Near Infrared Spectroscopy, TCD, processed electro encephalography) that, according to recent studies, can help to significantly improve neurological outcome after cardiac surgery in neonates and pediatric patients.

Aorta, Thoracic↗

A new semiempirical mathematical model for prediction of internal filtration in hollow fiber hemodialyzers.

The potential of convective solute transport for blood purification has been widely explored. New techniques (such as hemodiafiltration), based on a combination of diffusion and convection techniques, have been developed. Owing to the internal filtration/backfiltration (IF/BF) phenomenon, high-flux dialysis also relies on a convective component, which, however, is hard to quantify and thus optimize. In this work, we developed a mathematical model designed to supply the clinician with a quantification of the IF/BF fluxes taking place during high-flux dialysis. IF fluxes are predicted based on the machine settings and blood hematocrit/protein concentration. The hydraulic characteristics of commercial dialyzers were derived from bloodless bench tests. Moreover, an in vitro blood test was conducted on a 1.8 m(2) polysulfone dialyzer using an established scintigraphic analysis, for verification of model prediction accuracy. Results of simulations show that the IF/BF rate is sensitive to the blood flow rate and (to a lesser extent) to the dialysate flow rate. Increasing net ultrafiltration rates resulted in parallel increases of direct filtration and simultaneous decreases of BF. IF/BF is rather influenced by blood composition, due to the complex dependence of oncotic pressure and blood viscosity upon hematocrit and plasma protein concentration. Simulation results showed an excellent agreement with the experimental results obtained with scintigraphy, with only a 3% prediction error. With respect to some previous works, this model is simpler in its theoretical approach. It allows implementation into a user-friendly software tool and might be used to predict the convective component in high-flux dialysis and possibly to optimize it.

Computer Simulation↗

Current worldwide practice of dialysis dose prescription in acute renal failure.

PURPOSE OF REVIEW: The practice of renal replacement therapy for acute renal failure varies greatly around the world. This is especially true for the dose of renal replacement therapy. This review describes the epidemiology of dialysis prescription and delivery around the world based on recent observational studies and international surveys. Furthermore, a brief speculation on the concept of adequacy of therapy is provided. RECENT FINDINGS: Following the publication of the first large prospective randomized trial on the effects of treatment dose on outcome of patients with acute renal failure a certain consensus has been achieved on the adequacy of 35 ml/kg/h of clearance in continuous therapies. Surveys conducted in 1998 had demonstrated that such adequate therapy was only prescribed in a minority of patients. Recent observations based on questionnaires and surveys confirm that the number of centers prescribing adequate dialysis dose is increasing, but there is still a large number of institutions where prescription is made with no specific adequacy targets and effective delivery is not measured. Several barriers have been identified to reach adequacy targets including logistics, costs, personnel and others. SUMMARY: The analysis of the epidemiology of dialysis dose around the world shows a complex picture. Wide variations in practice are present although a significant effort has been made to standardize the prescription and delivery of therapy.

Acute Kidney Injury↗

Flow distribution analysis by helical scanning in polysulfone hemodialyzers: effects of fiber structure and design on flow patterns and solute clearances.

The efficiency of a hemodialyzer is largely dependent on its ability to facilitate diffusion, as this is the main mechanism by which small solutes are removed. The diffusion process can be impaired if there is a mismatch between blood and dialysate flow distribution in the dialyzer. The objective of the paper was to study the impact of different fiber bundle configurations on blood and dialysate flow distribution and urea clearances. The Optiflux 200 NR hemodialyzer was studied and the standard F 80 A hemodialyzer was used as a control for the study. Six dialyzers of each type were studied in vitro in the radiology department utilizing a new generation of helical computed tomography (CT) scan following contrast medium injection into the blood and dialysate compartment. Dynamic sequential imaging of longitudinal sections of the dialyzer was undertaken to detect flow distribution, average and peak velocities, and calculate wall shear rates. Six patients were dialyzed with 2 different dialyzers in random consecutive sequence. In these patients, 2 consecutive dialyses were carried out with identical operational parameters (Qb = 300 mL/min, Qd = 500 mL/min). In each session, blood and dialysate side urea clearances were measured at 30 and 150 min of treatment. Macroscopic and densitometrical analysis revealed that flow distribution was most homogeneous in the dialyzer with a new bundle configuration. Significantly increased urea clearances (p < 0.001) were seen with the Optiflux dialyzer compared with the standard dialyzer. In conclusion, more homogeneous dialysate blood and dialysate flow distribution and improved small solute clearances can be achieved by modifying the configuration of the filter bundle. These effects are achieved probably as a result of reduced blood to dialysate mismatch with reduction of flow channeling. The used radiological technique allows detailed flow distribution analysis and has the potential for testing future modifications to dialyzer design.

Blood Flow Velocity↗

Solute removal during continuous renal replacement therapy in critically ill patients: convection versus diffusion.

INTRODUCTION: The best modality, for continuous renal replacement therapy (CRRT) is currently uncertain and it is poorly understood how transport of different solutes, whether convective or diffusive, changes over time. METHODS: We conducted a prospective cross over study in a cohort of critically ill patients, comparing small (urea and creatinine) and middle (beta2 microglobulin) molecular weight solute clearance, filter lifespan and membrane performance over a period of 72 hours, during 15 continuous veno-venous dialysis (CVVHD) and 15 continuous veno-venous hemofiltration (CVVH)sessions. Both modalities were administered based on a prescription of 35 ml/kg/h and using polyacrylonitrile filters. RESULTS: Median filter lifespan was significantly longer during CVVHD (37 hours, interquartile range (IQR) 19.5 to 72.5) than CVVH (19 hours, IQR 12.5 to 28) (p = 0.03). Median urea time weighted average (TWA) clearances were not significantly different during CVVH (31.6 ml/minute, IQR 23.2 to 38.9) and CVVHD (35.7 ml/minute, IQR 30.1 to 41.5) (p = 0.213). Similar results were found for creatinine: 38.1 ml/minute, IQR 28.5 to 39, and 35.6 ml/minute, IQR 26 to 43 (p = 0.917), respectively. Median beta2m TWA clearance was higher during convective (16.3 ml/minute, IQR 10.9 to 23) than diffusive (6.27 ml/minute, IQR 1.6 to 14.9) therapy; nonetheless this difference did not reach statistical significance (p = 0.055). Median TWA adsorptive clearance of beta2m appeared to have scarce impact on overall solute removal (0.012 ml/minute, IQR -0.09 to 0.1, during hemofiltration versus -0.016 ml/minute, IQR -0.08 to 0.1 during dialysis; p = 0.79). Analysis of clearance modification over time did not show significant modifications of urea, creatinine and beta2m clearance in the first 48 hours during both treatments. In the CVVHD group, the only significant difference was found for beta2m between 72 hours and baseline clearance. CONCLUSION: Polyacrylonitrile filters during continuous hemofiltration and continuous hemodialysis delivered at 35 ml/kg/h are comparable in little and middle size solute removal. CVVHD appears to warrant longer CRRT sessions. The capacity of both modalities for removing such molecules is maintained up to 48 hours.

Adult↗

Year in review 2005: critical care--nephrology.

We summarize original research in the field of critical care nephrology accepted or published in 2005 in Critical Care and, when considered relevant or directly linked to this research, in other journals. The articles have been grouped into four categories to facilitate a rapid overview. First, physiopathology, epidemiology and prognosis of acute renal failure (ARF): an extensive review and some observational studies have been performed with the aim of describing aspects of ARF physiopathology, precise epidemiology and long-term outcomes. Second, several authors have performed clinical trials utilizing a potential nephro-protective drug, fenoldopam, with different results. Third, the issue of continuous renal replacement therapies dose has been addressed in a small prospective study and a large observational trial. And fourth, alternative indications to extracorporeal treatment of ARF and systemic inflammatory response syndrome have been explored by three original clinical studies.

Critical Care↗

Practice patterns in the management of acute renal failure in the critically ill patient: an international survey.

BACKGROUND: Several controversies have developed over acute renal failure (ARF) definition and treatment: which approach to patient care is most desirable and which form of renal replacement therapy (RRT) should be applied is an everyday matter of debate. There is also disagreement on clinical practice for RRT including the best timing to start, vascular access, anti-coagulation, membranes, equipment and finally, if continuous or intermittent techniques should be preferred. In this lack of harmony, the epidemiology of ARF has recently displayed an outbreak of cases in the intensive care units and nephrologists and intensivists are now called to work together in the case of such a syndrome. SUBJECTS AND METHODS: We report on the responses of 560 contributors, mostly coming from Europe, to a questionnaire submitted during the third International Course on Critical Care Nephrology held in Vicenza, Italy in June 2004. The questionnaire was divided into several sections concerning demographic and medical information, definition of ARF, practice of RRT, current opinions about clinical advantages and problems related to different RRTs and modalities, and beliefs on alternative indications to extracorporeal treatments. RESULTS: More then 200 different definitions of ARF and about 90 RRT start criteria were reported. Oliguria and RIFLE (an acronym classifying ARF in different levels of severity: Risk of renal dysfunction; Injury to the kidney; Failure of kidney function; Loss of kidney function; End-stage kidney disease.) were the most frequent criteria used to define ARF. In 10% of centres all forms of renal replacement techniques are available, and in 70% of cases two or more different techniques are available: absolute analysis of different techniques showed that continuous renal replacement therapies are utilized by 511 specialists (91%), intermittent haemodialysis by 387 (69%) and sustained low efficiency dialysis by 136 (24%). Treatment prescription showed significant differences among specialists, 60% of intensivists being uncertain on RRT dose prescription compared to 40% of nephrologists (P = 0.002). The most frequently selected dosage was '35 ml/kg/h' for urea (25%) and creatinine targets (26%), and '2-3 l/h' for the septic dose (25%). Of the participants, 90% said that they used RRT for non-renal indications, 60% although responders admitted the lack of scientific evidence as a limiting factor to its use. CONCLUSIONS: New classifications such as RIFLE criteria might improve well-known uncertainty about ARF definition. Different RRT techniques are available in most centres, but a general lack of treatment dose standardization is noted by our survey. Non-renal indications to RRT still need to find a definitive role in routine practice.

Acute Kidney Injury↗

Year in review: Critical Care 2004 - nephrology.

We summarize all original research in the field of critical care nephrology published in 2004 or accepted for publication in Critical Care and, when considered relevant or directly linked to this research, in other journals. Articles were grouped into four categories to facilitate a rapid overview. First, regarding the definition of acute renal failure (ARF), the RIFLE criteria (risk, injury, failure, loss, ESKD [end-stage kidney disease]) for diagnosis of ARF were defined by the Acute Dialysis Quality Initiative workgroup and applied in clinical practice by some authors. The second category is acid-base disorders in ARF; the Stewart-Figge quantitative approach to acidosis in critically ill patients has been utilized by two groups of researchers, with similar results but different conclusions. In the third category - blood markers during ARF - cystatin C as an early marker of ARF and procalcitonin as a sepsis marker during continuous venovenous haemofiltration were examined. Finally, in the extracorporeal treatment of ARF, the ability of two types of high cutoff haemofilters to influence blood levels of middle- and high-molecular-weight toxins showed promise.

Acid-Base Imbalance↗

Pulse high-volume haemofiltration for treatment of severe sepsis: effects on hemodynamics and survival.

INTRODUCTION: Severe sepsis is the leading cause of mortality in critically ill patients. Abnormal concentrations of inflammatory mediators appear to be involved in the pathogenesis of sepsis. Based on the humoral theory of sepsis, a potential therapeutic approach involves high-volume haemofiltration (HVHF), which has exhibited beneficial effects in severe sepsis, improving haemodynamics and unselectively removing proinflammatory and anti-inflammatory mediators. However, concerns have been expressed about the feasibility and costs of continuous HVHF. Here we evaluate a new modality, namely pulse HVHF (PHVHF; 24-hour schedule: HVHF 85 ml/kg per hour for 6-8 hours followed by continuous venovenous haemofiltration 35 ml/kg per hour for 16-18 hours). METHOD: Fifteen critically ill patients (seven male; mean Acute Physiology and Chronic Health Evaluation [APACHE] II score 31.2, mean Simplified Acute Physiology Score [SAPS] II 62, and mean Sequential Organ Failure Assessment 14.2) with severe sepsis underwent daily PHVHF. We measured changes in haemodynamic variables and evaluated the dose of noradrenaline required to maintain mean arterial pressure above 70 mmHg during and after pulse therapy at 6 and 12 hours. PHVHF was performed with 250 ml/min blood flow rate. The bicarbonate-based replacement fluid was used at a 1:1 ratio in simultaneous pre-dilution and post-dilution. RESULTS: No treatment was prematurely discontinued. Haemodynamics were improved by PHVHF, allowing a significant reduction in noradrenaline dose during and at the end of the PHVHF session; this reduction was maintained at 6 and 12 hours after pulse treatment (P = 0.001). There was also an improvement in systolic blood pressure (P = 0.04). There were no changes in temperature, cardiac index, oxygenation, arterial pH or urine output during the period of observation. The mean daily Kt/V was 1.92. Predicted mortality rates were 72% (based on APACHE II score) and 68% (based on SAPS II score), and the observed 28-day mortality was 47%. CONCLUSION: PHVHF is a feasible modality and improves haemodynamics both during and after therapy. It may be a beneficial adjuvant treatment for severe sepsis/septic shock in terms of patient survival, and it represents a compromise between continuous renal replacement therapy and HVHF.

Acid-Base Equilibrium↗

In vivo validation of the adequacy calculator for continuous renal replacement therapies.

INTRODUCTION: The study was conducted to validate in vivo the Adequacy Calculator, a Microsoft Excel-based program, designed to assess the prescription and delivery of renal replacement therapy in the critical care setting. METHODS: The design was a prospective cohort study, set in two intensive care units of teaching hospitals. The participants were 30 consecutive critically ill patients with acute renal failure treated with 106 continuous renal replacement therapies (CRRT). Urea clearance computation was performed with the Adequacy Calculator (KCALC). Simultaneous blood and effluent urea samples were collected to measure the effectively delivered urea clearance (KDEL) at the beginning of each treatment and, during 73 treatments, between the 18th and 24th treatment hour. The correlation between 179 computed and 179 measured clearances was assessed. Fractional clearances for urea were calculated as spKt/V (where sp represents single pool, K is clearance, t is time, and V is urea volume of distribution) obtained from software prescription and compared with the delivered spKt/V obtained from empirical data. RESULTS: We found that the value of clearance predicted by the calculator was strongly correlated with the value obtained from computation on blood and dialysate determination (r = 0.97) during the first 24 treatment hours, regardless of the renal replacement modality used. The delivered spKt/V (1.25) was less than prescribed (1.4) from the Adequacy Calculator by 10.7%, owing to therapy downtime. CONCLUSION: The Adequacy Calculator is a simple tool for prescribing CRRT and for predicting the delivered dose. The calculator might be a helpful tool for standardizing therapy and for comparing disparate treatments, making it possible to perform large multi-centre studies on CRRT.

Acute Kidney Injury↗

Renal replacement II: dialysis dose.

Improved survival of critically ill acute renal failure patients can be correlated with therapy dose. The overall solute elimination can be measured by the product of clearance and time (Kt), which is usually normalized for the volume of distribution (V) of the solute as "Kt/V." Setting a Kt/V threshold of 1.4 can guide clinicians toward adequate treatment. This is a slightly higher prescription than the current value for chronic dialysis. However, the true uraemic toxins probably diffuse among body compartments less readily than urea and, as such, the frequency of renal replacement therapy should be more important to its efficiency, and should be optimal with continuous therapy. In the absence of an optimal dialysis dose, it can only be recommended that the prescription should exceed that calculated to be "adequate."

Acute Kidney Injury↗

Prophylactic fenoldopam for renal protection in sepsis: a randomized, double-blind, placebo-controlled pilot trial.

OBJECTIVE: Acute renal failure is common in septic patients. Fenoldopam, a dopamine-1 receptor agonist, increases renal blood flow and may, therefore, reduce the risk of acute renal failure in such patients. Accordingly, we sought to determine the safety and efficacy of fenoldopam for the prevention of acute renal failure in septic patients. DESIGN: Prospective, double-blind, placebo-controlled trial. SETTING: Three multidisciplinary intensive care units at a university hospital. PATIENTS: Three hundred septic patients with baseline serum creatinine concentrations <150 micromol/L. INTERVENTIONS: We randomized patients to a continuous infusion of either fenoldopam (n = 150) at 0.09 microg x kg x min or placebo (n = 150) while in the intensive care unit. The primary outcome measure was the incidence of acute renal failure, defined as a serum creatinine concentration increase to >150 micromol/L, during study drug infusion. MEASUREMENTS AND MAIN RESULTS: The incidence of acute renal failure was significantly lower in the fenoldopam group compared with the control group (29 vs. 51 patients; p = .006). The odds ratio of developing acute renal failure for patients treated with fenoldopam was estimated to be 0.47 (p = .005). The difference in the incidence of severe acute renal failure (creatinine >300 mumol/L), however, failed to achieve statistical significance (10 vs. 21; p = .056). The length of intensive care unit stay in surviving patients was significantly lower in the fenoldopam group compared with the control group (10.64 +/- 9.3 vs. 13.4 +/- 14.0; p < .001). There were no complications of fenoldopam infusion. A direct effect of treatment on the probability of death, beyond its effect on acute renal failure, was not significant (odds ratio = 0.68, p = .1). CONCLUSIONS: Compared with placebo, low-dose fenoldopam resulted in a smaller increase in serum creatinine in septic patients. The clinical significance of this finding is uncertain. A large multiple-center trial is now needed to confirm these findings.

Acute Kidney Injury↗

A new machine for continuous renal replacement therapy: from development to clinical testing.

A new continuous renal replacement therapy machine has been designed to fulfill the expectations of nephrologists and intensivists operating in the common ground of critical care nephrology. The new equipment is called Prismaflex and it is the natural evolution of the PRISMA machine that has been utilized worldwide for continuous renal replacement therapy in the last 10 years. The authors performed a preliminary alpha-trial to establish the usability, flexibility and reliability of the new device. Accuracy was also tested by recording various operational parameters during different intermittent and continuous renal replacement modalities during 62 treatments. This article will describe our first experience with this new device and touch upon the historic and technologic background leading to its development.

Clinical Trials as Topic↗

Extracorporeal therapies in non-renal disease: treatment of sepsis and the peak concentration hypothesis.

In the setting of intensive care, patients with acute renal failure often present a clinical picture of the systemic inflammatory response syndrome (SIRS). SIRS can be caused by bacterial stimuli or by non-microbiological stimuli that induce a significant inflammatory response. When this response is exaggerated, the patient experiences multiple organ system failure and a condition of sepsis also defined as a systemic malignant inflammation. This is mostly characterized by an invasion of cytokines and other pro-inflammatory mediators into the systemic circulation where major biological effects take place, including vasopermeabilization, hypotension and shock. At the same time, the monocyte of the septic patient seems to be hyporesponsive to inflammatory stimuli to a certain extent. In this condition, the patient faces a situation of hyperinflammation but at the same time of immunodepression expressing a clinical entity defined as counter anti-inflammatory response syndrome. The general picture of the clinical disorder is therefore better characterized by an immunodysregulation than by a simple pro- or anti-inflammatory disorder. Due to the short half-life of cytokines and other mediators spilled over into the circulation, it is extremely difficult to approach the problem at the right moment with the right pharmacological agent. For these reasons, the peak concentration hypothesis suggests that continuous renal replacement therapies, due to their continuity and unspecific capacity of removal, might be beneficial in cutting the peaks of the concentrations of both pro- and anti-inflammatory mediators, restoring a situation of immunohomeostasis. Thus the patient may benefit from a lesser degree of immunodysregulation and he/she may restore a close-to-normal capacity of response to exogenous stimuli.

Animals↗