PubMed Health⌕ Search

Biomedical subjects

Zhaowei Liu

Publications and source records attributed to Zhaowei Liu.

5 recordsLinked to original sources

Efficient gene-driven germ-line point mutagenesis of C57BL/6J mice.

BACKGROUND: Analysis of an allelic series of point mutations in a gene, generated by N-ethyl-N-nitrosourea (ENU) mutagenesis, is a valuable method for discovering the full scope of its biological function. Here we present an efficient gene-driven approach for identifying ENU-induced point mutations in any gene in C57BL/6J mice. The advantage of such an approach is that it allows one to select any gene of interest in the mouse genome and to go directly from DNA sequence to mutant mice. RESULTS: We produced the Cryopreserved Mutant Mouse Bank (CMMB), which is an archive of DNA, cDNA, tissues, and sperm from 4,000 G1 male offspring of ENU-treated C57BL/6J males mated to untreated C57BL/6J females. Each mouse in the CMMB carries a large number of random heterozygous point mutations throughout the genome. High-throughput Temperature Gradient Capillary Electrophoresis (TGCE) was employed to perform a 32-Mbp sequence-driven screen for mutations in 38 PCR amplicons from 11 genes in DNA and/or cDNA from the CMMB mice. DNA sequence analysis of heteroduplex-forming amplicons identified by TGCE revealed 22 mutations in 10 genes for an overall mutation frequency of 1 in 1.45 Mbp. All 22 mutations are single base pair substitutions, and nine of them (41%) result in nonconservative amino acid substitutions. Intracytoplasmic sperm injection (ICSI) of cryopreserved spermatozoa into B6D2F1 or C57BL/6J ova was used to recover mutant mice for nine of the mutations to date. CONCLUSIONS: The inbred C57BL/6J CMMB, together with TGCE mutation screening and ICSI for the recovery of mutant mice, represents a valuable gene-driven approach for the functional annotation of the mammalian genome and for the generation of mouse models of human genetic diseases. The ability of ENU to induce mutations that cause various types of changes in proteins will provide additional insights into the functions of mammalian proteins that may not be detectable by knockout mutations.

Animals↗

Temperature gradient capillary electrophoresis (TGCE)--a tool for the high-throughput discovery and mapping of SNPs and IDPs.

Temperature gradient capillary electrophoresis (TGCE) can be used to distinguish heteroduplex from homoduplex DNA molecules and can thus be applied to the detection of various types of DNA polymorphisms. Unlike most single nucleotide polymorphism (SNP) detection technologies, TGCE can be used even in the absence of prior knowledge of the sequences of the underlying polymorphisms. TGCE is both sensitive and reliable in detecting SNPs, small InDel (insertion/deletion) polymorphisms (IDPs) and simple sequence repeats, and using this technique it is possible to detect a single SNP in amplicons of over 800 bp and 1-bp IDPs in amplicons of approximately 500 bp. Genotyping data obtained via TGCE are consistent with data obtained via gel-based detection technologies. For genetic mapping experiments, TGCE has a number of advantages over alternative heteroduplex-detection technologies such as celery endonuclease (CELI) and denaturing high-performance liquid chromatography (dHPLC). Multiplexing can increase TGCE's throughput to 12 markers on 94 recombinant inbreds per day. Given its ability to efficiently and reliably detect a variety of subtle DNA polymorphisms that occur at high frequency in genes, TGCE shows great promise for discovering polymorphisms and conducting genetic mapping and genotyping experiments.

Chromosome Mapping↗

Identification of mutations from phenotype-driven ENU mutagenesis in mouse chromosome 7.

We have used the new high-throughput mutation-scanning technique temperature-gradient capillary electrophoresis (TGCE) for the identification of point mutations induced by N-ethyl-N-nitrosourea (ENU) in the mouse genome. TGCE detects the presence of heteroduplex molecules formed between a wild-type gene segment and the corresponding homologous segment containing an induced mutation or a naturally occurring single nucleotide polymorphism (SNP). Partially denatured heteroduplex molecules are resolved from homoduplexes by virtue of their differential mobilities during capillary electrophoresis conducted in a finely controlled temperature gradient. Simultaneous heteroduplex analysis of 96 amplicons ranging from 150 to 600 bp in size is achieved in approximately 45 min without the need for predetermining the melting profile of each fragment. Initially, we exploited known mouse mutations to develop TGCE protocols for analyzing unpurified PCR samples amplified from crude tail-DNA preparations. TGCE was then applied to the rapid identification of three new ENU-induced mutations recovered from regional mutagenesis screens of a segment of mouse Chromosome 7. Enzyme assays and quantitative reverse transcription-PCR (qRT-PCR) methods validated these new mutations. Our data demonstrate that rapid mutation scanning with TGCE, followed by sequence verification only of detected positives, is an efficient approach to the identification of point mutations in the mouse genome.

Animals↗

Focusing surface plasmons with a plasmonic lens.

We report the focusing of surface plasmon polaritons by circular and elliptical structures milled into optically thick metallic films or plasmonic lenses. Both theoretical and experimental data for the electromagnetic nearfield is presented. The nearfield is mapped experimentally using nearfield scanning optical microscopy and plasmonic lithography. We find that the intensity at the focal points of the plasmonic lenses increases with size.

Journal Article↗

Integrated platform for detection of DNA sequence variants using capillary array electrophoresis.

We have developed a highly versatile platform that performs temperature gradient capillary electrophoresis (TGCE) for mutation/single-nucleotide polymorphism (SNP) detection, sequencing and mutation/SNP genotyping for identification of sequence variants on an automated 24-, 96- or 192-capillary array instrument. In the first mode, multiple DNA samples consisting of homoduplexes and heteroduplexes are separated by CE, during which a temperature gradient is applied that covers all possible temperatures of 50% melting equilibrium (Tms) for the samples. The differences in Tms result in separation of homoduplexes from heteroduplexes, thereby identifying the presence of DNA variants. The sequencing mode is then used to determine the exact location of the mutation/SNPs in the DNA variants. The first two modes allow the rapid identification of variants from the screening of a large number of samples. Only the variants need to be sequenced. The third mode utilizes multiplexed single-base extensions (SBEs) to survey mutations and SNPs at the known sites of DNA sequence. The TGCE approach combined with sequencing and SBE is fast and cost-effective for high-throughput mutation/SNP detection.

DNA↗