PubMed Health⌕ Search

Biomedical subjects

Zhaoyang Wu

Publications and source records attributed to Zhaoyang Wu.

4 recordsLinked to original sources

Stable chloroform emissions in southeastern China: insights from recent observations.

Chloroform (CHCl3) is a short-lived ozone-depleting substance not currently regulated under the Montreal Protocol. Due to the unique meteorological conditions in East Asia, CHCl3 emitted in this region has a greater potential to reach the stratosphere and contribute to ozone depletion. As an essential component of national CHCl3 emissions, southeastern China has attracted increasing attention. However, long-term observational data in this region remain relatively scarce, with no updates since 2020. In this study, we continuously measured atmospheric CHCl3 concentrations at a remote monitoring station in southeastern China from 1 June 2023 to 31 May 2025. Frequent concentration enhancements were observed during the monitoring period, with mixing ratios ranging from 9.3 to 134.1 ppt and an average value of 36.8 ± 19.7 ppt. Back-trajectory analysis indicated that air masses associated with elevated CHCl3 levels primarily originated from coastal industrial provinces in eastern China. Using the Potential Source Contribution Function and Concentration Weighted Trajectory methods, we identified the Yangtze River Delta (Jiangsu, Anhui, and Zhejiang Provinces) and Jiangxi Province as dominant source regions. Emissions of CHCl3 in southeastern China were estimated using the Tracer Ratio Method to be approximately 30.1 ± 5.3 Gg/yr from 2023-06-01 to 2025-05-31, indicating overall stability relative to earlier estimates and no apparent upward trend. These findings provide updated insights into the current status of CHCl3 emissions in southeastern China and highlight the need for continued monitoring and emission assessment of CHCl3 in East Asia, given its unregulated status and implications for ozone layer recovery.

Air Pollutants↗

A novel biosensing interfacial design produced by assembling nano-Au particles on amine-terminated plasma-polymerized films.

A novel biosensing interfacial design strategy has, for the first time, been produced by assembling nano-Au particles on amine-terminated plasma-polymerized films (PPF). A quartz-crystal microbalance (QCM) as a model transducer was deposited with PPF of n-butylamine by use of a glow discharge and then treated with nano-Au particles. The kinetic assembly process and conditions were studied using the real-time-output device and the surface topology of the resulting crystal was characterized by atomic force microscopy (AFM) imaging. Based on analysis of the experimental data, including the association constant of Au-amine interaction, the assembly mechanism is considered to be partly or even mainly chemical adsorption. Moreover, immobilization of anti-human IgM antibody (IgM Ab), as an example, on the developed PPF-Au interface was investigated. It was found that antibody molecules immobilized by the proposed procedure had higher immunological activity than those immobilized by the conventional glutaraldehyde (GLU) cross-linking procedure or the direct gold-attachment procedure. The newly developed sensor had a better response, with a detection limit of IgM concentration as low as approximately 1.00 microg mL(-1). In particular, the extremely high stability of both PPF and nano-Au monolayer formulated allows the designed biosensing interface to withstand harsh regeneration treatment, making it reusable.

Biosensing Techniques↗

A piezoelectric immunoassay based on self-assembled monolayers of cystamine and polystyrene sulfonate for determination of Schistosoma japonicum antibodies.

A piezoelectric immunosensor based on an improved immobilization strategy combining self-assembled monolayers (SAM) of cystamine (Cys) and polystyrene sulfonate (PSS) has been developed for the determination of Schistosoma japonicum antibodies (SjAb) in rabbit serum. Cys SAM were first applied to the gold electrode surface of the crystal, serving as a positively-charged base. Schistosoma japonicum antigen (SjAg) was then electrostatically immobilized on the crystal by means of a negatively-charged PSS layer. When sealed by use of an appropriately selected blocking reagent for BSA and normal rabbit serum (NRS), non-specific adsorption could be substantially reduced. The immunosensor was used to determine SjAb in optimized buffer medium with addition of poly(ethylene glycol) (PEG), which served as an immunoreaction enhancer. It was shown experimentally that SjAg immobilized by the Cys-PSS adsorption procedure had higher immunological activity or binding efficiency than those immobilized by the glutaraldehyde (GLU) binding or direct attachment procedures. The immunosensor developed had satisfactory sensitivity and detection limit, and regeneration of the piezoelectric quartz-crystal was easy. Analytical results obtained with infected rabbit serum samples indicated that the proposed immunosensor is a promising alternative for qualitative and quantitative determination of SjAb in clinical diagnosis of infection with Schistosoma japonicum.

Adsorption↗

Renewable urea sensor based on a self-assembled polyelectrolyte layer.

A renewable urea sensor based on a carboxylic poly(vinyl chloride) (PVC-COOH) matrix pH-sensitive membrane has been proposed, in which a positively charged polyelectrolyte layer is first constructed by using a self-assembly technique on the surface of a PVC-COOH membrane, and urease, with negative charges, is then immobilized through electrostatic adsorption onto the PVC-COOH membrane, by controlling the pH of the urease solution below its isoelectric point. The response characteristics of the PVC-COOH pH-sensitive membrane and the effects of experimental conditions have been investigated in detail. Compared with conventional covalent immobilization, the urea sensor made with this self-assembly immobilization shows significant advantage in terms of sensitivity and ease of regeneration. The potential responses of the urea sensor with self-assembly immobilization increase with the urea concentration over the concentration range 10(-5) - 10(-1) mol l(-1), and the detection limit is 0.028 mmol(-1). Moreover, this type of urea sensor can be repeatedly regenerated by using a simple washing treatment with 0.01 mol l(-1) NaOH (containing 0.5 mol l(-1) NaCl) and 0.01 mol l(-1) HCl. The urease layers and the polyelectrolyte layers on the PVC-COOH membrane are removed, the potential response of the sensor to urea solutions of different concentrations returns nearly to zero, and another assembly cycle of urease and polyelectrolyte can then be carried out.

Biosensing Techniques↗