Handheld rectilinear ion trap mass spectrometer.

A shoebox-sized, 10-kg, handheld mass spectrometer, Mini 10, based on a rectilinear ion trap mass analyzer has been designed, built, and characterized. This instrument has evolved from a decade-long experimental and simulation program in mass spectrometer miniaturization. The rectilinear ion trap has a simplified geometry and high trapping capacity, and when used with a miniature and ruggedized pumping system, it allows chemical analysis while the instrument is being carried. Compact electronics, including an air core RF drive coil, were developed to control the instrument and to record mass spectra. The instrument runs on battery power, consuming less than 70 W, similar to a laptop computer. Wired and wireless networking capabilities are implemented. The instrument gives unit resolution and a mass range of over m/z 500. Tandem mass spectrometry capabilities are implemented using collision-induced dissociation, and they are used to provide confirmation of chemical structure during in situ analysis. Continuous monitoring of air and solution samples is demonstrated, and a limit of detection of 50 ppb was obtained for toluene vapor in air and for an aqueous naphthalene solution using membrane sample introduction.

Journal Article↗

CASTp: computed atlas of surface topography of proteins with structural and topographical mapping of functionally annotated residues.

Cavities on a proteins surface as well as specific amino acid positioning within it create the physicochemical properties needed for a protein to perform its function. CASTp (http://cast.engr.uic.edu) is an online tool that locates and measures pockets and voids on 3D protein structures. This new version of CASTp includes annotated functional information of specific residues on the protein structure. The annotations are derived from the Protein Data Bank (PDB), Swiss-Prot, as well as Online Mendelian Inheritance in Man (OMIM), the latter contains information on the variant single nucleotide polymorphisms (SNPs) that are known to cause disease. These annotated residues are mapped to surface pockets, interior voids or other regions of the PDB structures. We use a semi-global pair-wise sequence alignment method to obtain sequence mapping between entries in Swiss-Prot, OMIM and entries in PDB. The updated CASTp web server can be used to study surface features, functional regions and specific roles of key residues of proteins.

Amino Acids↗

Ion trajectory simulation for electrode configurations with arbitrary geometries.

A multi-particle ion trajectory simulation program ITSIM 6.0 is described, which is capable of ion trajectory simulations for electrode configurations with arbitrary geometries. The electrode structures are input from a 3D drawing program AutoCAD and the electric field is calculated using a 3D field solver COMSOL. The program CreatePot acts as interface between the field solver and ITSIM 6.0. It converts the calculated electric field into a field array file readable by ITSIM 6.0 and ion trajectories are calculated by solving Newton's equation using Runge-Kutta integration methods. The accuracy of the field calculation is discussed for the ideal quadrupole ion trap in terms of applied mesh density. Electric fields of several different types of devices with 3D geometry are simulated, including ion transport through an ion optical system as a function of pressure. Ion spatial distributions, including the storage of positively charged ions only and simultaneous storage of positively/negatively charged ions in commercial linear ion traps with various geometries, are investigated using different trapping modes. Inelastic collisions and collision induced dissociation modeled using RRKM theory are studied, with emphasis on the fragmentation of n-butylbenzene inside an ideal quadrupole ion trap. The mass spectrum of 1,3-dichlorobenzene is simulated for the rectilinear ion trap device and good agreement is observed between the simulated and the experimental mass spectra. Collisional cooling using helium at different pressures is found to affect mass resolution in the rectilinear ion trap.

Journal Article↗

Detection Technologies. Ambient mass spectrometry.

A recent innovation in mass spectrometry is the ability to record mass spectra on ordinary samples, in their native environment, without sample preparation or preseparation by creating ions outside the instrument. In desorption electrospray ionization (DESI), the principal method described here, electrically charged droplets are directed at the ambient object of interest; they release ions from the surface, which are then vacuumed through the air into a conventional mass spectrometer. Extremely rapid analysis is coupled with high sensitivity and high chemical specificity. These characteristics are advantageously applied to high-throughput metabolomics, explosives detection, natural products discovery, and biological tissue imaging, among other applications. Future possible uses of DESI for in vivo clinical analysis and its adaptation to portable mass spectrometers are described.

Animals↗

Novel linear ion trap mass analyzer composed of four planar electrodes.

A novel linear ion trap mass analyzer was developed using just four elongated planar electrodes, mounted in parallel, and employing an RF potential for ion trapping in the radial and axial directions. Mass analysis was achieved using the mass-selective instability scan with ion ejection in the radial direction. The performance of this new device was characterized in comparison with the 6-electrode rectilinear ion trap (RIT) from which it is derived. The 4-electrode trap gives optimum performance in an asymmetric geometry, just like the original optimized 6-electrode RIT. The strong RF fringing fields at the ends of the RF rods account for axial ion trapping without use of extra electrodes or an axial DC voltage. Field calculations and simulations have been carried out to study the trapping potential inside RITs with various configurations. Demonstrated capabilities include analysis of externally injected ions with mass resolution in excess of 1000 and a mass/charge range of 650 Th as well as tandem mass spectrometry capabilities. The geometric simplicity and performance characteristics of the 4-electrode RIT make it particularly attractive in the development of next generation miniaturized mass spectrometers.

Journal Article↗

Rectilinear ion trap mass spectrometer with atmospheric pressure interface and electrospray ionization source.

A rectilinear ion trap (RIT) mass analyzer was incorporated into a mass spectrometer fitted with an electrospray ionization source and an atmospheric pressure interface. The RIT mass spectrometer, which was assembled in two different configurations, was used for the study of biological compounds, for which performance data are given. A variety of techniques, including the use of a balanced rf, elevated background gas pressure, automatic gain control, and resonance ejection waveforms with dynamically adjusted amplitude, were applied to enhance performance. The capabilities of the instrument were characterized using proteins, peptides, and pharmaceutical drugs. Unit resolution and an accuracy of better than m/z 0.2 was achieved for mass-to-charge (m/z) ratios up to 2000 Th at a scan rate of approximately 3000 amu/(charge.s) while reduced scan rates gave greater resolution and peak widths of less than m/z 0.5 over the same range. The mass discrimination in trapping externally generated ions was characterized over the range m/z 190-2000 and an optimized low mass cutoff value of m/z 120-140 was found to give equal trapping efficiencies over the entire range. The radial detection efficiency was measured as a function of m/z ratio and found to rise from 35% at low m/z values to more than 90% for ions of m/z 1800. The way in which the ion trapping capacity depends on the dc trapping potential was investigated by measuring the mass shift due to space charge effects, and it was shown that low trapping potentials minimize space charge effects by increasing the useful volume of the device. The collision-induced dissociation (CID) capabilities of the RIT instrument were evaluated by measuring isolation efficiency as a function of mass resolution as well as measuring peptide CID efficiencies. Overall CID efficiencies of more than 60% were easily reached, while isolation of an ion with unit resolution at m/z 524 was achieved with high rejection (>95%) of the adjacent ions. The overall analytical capabilities of the ESI-RIT instrument were demonstrated with the analysis of a mixture of pharmaceutical compounds using multiple-stage mass spectrometry.

Apoproteins↗

Gentle protein ionization assisted by high-velocity gas flow.

Gentle protein electrospray ionization is achieved using the high-velocity gas flow of an air amplifier to improve desolvation in conventional ESI and generate intact folded protein ions in the gas phase. Comparisons are made between the ESI spectra of a number of model proteins, including ubiquitin, cytochrome c, lysozyme, and myoglobin, over a range of pH values under optimized conditions, with and without using an air amplifier to achieve high-velocity gas flow. Previously reported increased ion signals are confirmed. In addition, the peaks recorded using the air amplifier are shown to be narrower, corresponding to more complete desolvation. Significant changes in the charge-state distribution also are observed, with a shift to lower charge state at high-velocity flow. The relationship between the observed charge-state distribution and protein conformation was explored by comparing the charge-state shifts and the distributions of charge states for proteins that are or are not stable in their native conformations in low pH solutions. The data suggest retention of native or nativelike protein conformations using the air amplifier in all cases examined. This is explained by a mechanism in which the air amplifier rapidly creates small droplets from the original large ESI droplets and these microdroplets then desolvate without a significant decrease in pH, resulting in retention of the folded protein conformations. Furthermore, the holoform of ionized myoglobin is visible at pH 3.5, a much lower value than the minimum needed to see this form in conventional ESI. These results provide evidence for the importance of the conditions used in the desolvation process for the preservation of the protein conformation and suggest that the conditions achieved when using high-velocity gas flows to assist droplet evaporation and ion desolvation are much gentler than those in conventional ESI experiments.

Cytochromes c↗

High-throughput mass spectrometer using atmospheric pressure ionization and a cylindrical ion trap array.

The analytical performance of an atmospheric pressure sampling, multiple-channel, high-throughput mass spectrometer was investigated using samples of a variety of types. The instrument, based on an array of cylindrical ion traps, was built with four independent channels and here is operated using two fully multiplexed channels (sources, ion optics, ion traps, detectors) capable of analyzing different samples simultaneously. Both channels of the instrument were incorporated within the same vacuum system and operated using a common set of control electronics. A multichannel electrospray ionization source was assembled and used to introduce samples including solutions of organic compounds, peptides, and proteins simultaneously into the instrument in a high-throughput fashion. Cross-talk between the channels of the instrument occurred in the detection system and could be minimized to 1-2% using shielding between detector channels. In this initial implementation of the instrumentation, an upper mass/charge limit of approximately 1300 Th was observed (+13 charge state of myoglobin) and unit mass/charge resolution was achieved to approximately 800 Th. The rather limited dynamic range (2-3 orders of magnitude for low-concentration analytes) is due to cross-talk contributions from more concentrated species introduced into a different channel. Analysis of mixtures of alkylamines and peptides is demonstrated, but analysis of mixtures with a wide spread in mass/charge ratios was not possible due to mass discrimination in the ion optics. Further refinement of the vacuum system and ion optics will allow the addition of more channels of parallel mass analysis and facilitate applications in fields such as proteomics and metabolomics.

Amines↗

Ion/molecule reactions in a miniature RIT mass spectrometer.

Ion/molecule reactions were explored in a newly developed miniature mass spectrometer fitted with a rectilinear ion trap (RIT) mass analyzer. The tandem mass spectrometry performance of this instrument is demonstrated using collision induced dissociation (CID) and ion/molecule reactions. The latter includes Eberlin transacetalization reactions and electrophilic additions. Selective detection of the chemical warfare simulant dimethyl methyl phosphonate (DMMP) was achieved through selective Eberlin reactions of its characteristic phosphonium fragment ion CH3OP(+)(O)CH3 (m/z 93), with 1,4-dioxane or 1,3-dioxolane. Efficient adduct formation as a result of electrophilic attack by the phosphonium ion on various nucleophilic reagents, including 1,1,3,3-tetramethyl urea, methanesulfonic acid methyl ester, dimethyl sulfoxide and methyl salicylate, was also observed using the RIT device. The product ions of these reactions were analyzed using CID and the characteristic fragmentation patterns of the ionic addition products were recorded using multiple-stage experiments in the miniature RIT instrument. This study clearly demonstrates that a small, home-built, miniature RIT mass spectrometer can be used to perform analytically useful ion/molecule reactions and also that instruments like this have the potential to provide a portable platform for in situ detection of organophosphorus esters and related compounds with high specificity using tandem mass spectrometry.

Journal Article↗

Preparative linear ion trap mass spectrometer for separation and collection of purified proteins and peptides in arrays using ion soft landing.

A preparative mass spectrometer for microarray fabrication is reported. The instrument includes an atmospheric pressure ionization source, a linear ion trap mass analyzer, an ion collection surface positioning system, and a surface loading chamber with independent vacuum pumping. It was designed for the production of protein arrays using the ion soft-landing technique to collect ions on a surface after separation by mass/charge ratio. Small microarrays have been prepared by isolating and soft landing individual protein or peptide ions after electrospray ionization of mixtures. The composition and purity of the separated materials has been confirmed using independent external mass spectrometric analysis of rinse solutions of the collected spots, either by the new method of electrosonic spray ionization MS or by nanospray ionization MS. The ability to retain bioactivity in the mass-selected and collected biomolecules has been demonstrated in particular cases. The reported instrument has also been characterized as an analytical mass spectrometer.

Amino Acid Sequence↗

Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer.

A mass analyzer based on a rectilinear geometry ion trap (RIT) has been built, and its performance has been characterized. Design concepts for this type of ion trap are delineated with emphasis on the effects of electrode geometry on the calculated electric field. The Mathieu stability region was mapped experimentally. The instrument can be operated using mass-selective instability scans in both the boundary and resonance ejection versions. Comparisons of performance between different versions of the device having different dimensions allowed selection of an optimized geometry with an appropriate distribution of higher-order electric fields. Comparisons made under the same conditions between the performance of a conventional cylindrical ion trap and a RIT of 4 times greater volume show an improvement of 40 times in the signal-to-noise ratio resulting from the higher ion trapping capacity of the RIT. The demonstrated capabilities of the RIT include tandem mass spectrometry, a mass resolution in excess of 1000, and a mass/charge range of 650 Th, all in a simple structure that is only 3.5 cm(3) in internal volume.

Equipment Design↗

Ion soft-landing into liquids: Protein identification, separation, and purification with retention of biological activity.

Protein ions, after mass spectrometric separation, can be soft-landed into liquid surfaces with preservation of their native structures. Retention of biological activity is strongly favored in glycerol-based surfaces but not in self-assembled monolayer solid surfaces. Soft-landing efficiency for multiply-charged hexokinase ions was found to be some four times higher for a glycerol/fructose liquid surface than for a fluorinated self-assembled monolayer surface. Soft-landing into liquid surfaces is also shown to allow (1) protein purification, (2) on-surface identification of the soft-landed material using MALDI, and (3) protein identification by in-surface tryptic digestion. Pure lysozyme was successfully isolated from different mixtures including an oxidized, partially decomposed batch of the protein and a partial tryptic digest. Liquid glycerol/carbohydrate mixtures could be used directly to record MALDI spectra on the soft-landed compounds provided they were fortified in advance with traditional MALDI matrices such as p-nitroaniline and alpha-cyano-4-hydroxycinnamic acid. Various proteins were soft-landed and detected on-target using these types of liquid surface. Soft-landing of multiply-charged lysozyme ions onto fluorinated self-assembled monolayer surfaces was found to occur with a limited amount of neutralization, and trapped multiply-charged ions could be desorbed from the surface by laser desorption. Initial data is shown for a new approach to protein identification that combines top-down and bottom-up approaches by utilizing protein ion soft-landing from a protein mixture, followed by tryptic digestion of the landed material and detection of characteristic tryptic fragments by MALDI.

Amino Acid Sequence↗

Preparing protein microarrays by soft-landing of mass-selected ions.

Intact, multiply protonated proteins of particular mass and charge were selected from ionized protein mixtures and gently landed at different positions on a surface to form a microarray. An array of cytochrome c, lysozyme, insulin, and apomyoglobin was generated, and the deposited proteins showed electrospray ionization mass spectra that matched those of the authentic compounds. Deposited lysozyme and trypsin retained their biological activity. Multiply charged ions of protein kinase A catalytic subunit and hexokinase were also soft-landed into glycerol-based liquid surfaces. These soft-landed kinases phosphorylated LRRASLG oligopeptide and D-fructose, respectively.

Apoproteins↗

A strategy for metabolite identification using triple-quadrupole mass spectrometry with enhanced resolution and accurate mass capability.

Using a single platform of a triple-quadrupole mass spectrometer equipped with enhanced resolution and accurate mass capabilities, a strategy for metabolite identification of a drug in a biological matrix has been demonstrated. The strategy is based on first screening for metabolites via neutral loss and precursor ion scan schemes, devised as the result of the product ion spectrum of a matrix-free standard of the drug. The accurate masses of the precursor ions identified via the two scan schemes plus the precursor ions of structurally likely metabolites are then determined by enhanced resolution, accurate mass (AM) selected ion monitoring (SIM). The identities of the metabolites are further established by determining the accurate masses of the product ions via enhanced resolution AM selected reaction monitoring (SRM). The feasibility of the strategy was demonstrated using a liver microsome incubation sample of nefazodone, an antidepressant drug. The neutral loss and precursor ion screening runs were able to identify most of the metabolites of nefazodone. The subsequent SIM and SRM experiments gave mass accuracy of better than +/-0.003 u for the masses of the precursor and product ions of nefazodone and all the metabolites. The ability to perform metabolite screening by using the scan features followed by accurate mass determinations on the same instrument is an attractive feature of using a triple-quadrupole mass spectrometer with enhanced resolution and accurate mass capability.

Animals↗

Enhanced resolution triple-quadrupole mass spectrometry for fast quantitative bioanalysis using liquid chromatography/tandem mass spectrometry: investigations of parameters that affect ruggedness.

In order to increase sample analysis throughput, the use of fast liquid chromatography in quantitative bioanalysis based on liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) has become prevalent. Therefore, it is important to increase the specificity of such bioanalytical methods. This can be done by enhancing both the chromatographic and mass resolving power. Increasing the mass spectrometric resolving power to minimize interference from endogenous compounds in the biological matrix is the subject of this paper. We present the results of our experience with developing and validating SRM-based, enhanced resolution bioanalytical methods using a new triple-quadrupole mass spectrometer with enhanced resolution capability. We have shown that SRM bioanalytical methods using better than unit-mass resolution (Q1 FWHM = 0.2 Th, Q3 FWHM = 0.7 Th) can be developed which are as rugged as unit resolution methods (Q1 FWHM = 0.7 Th, Q3 FWHM = 0.7 Th). The enhanced resolution methods require more attention to detail than unit resolution methods. For instance, the mass setting for precursor ion selection is more critical because the mass peak is narrower. Because of this, enhanced resolution methods may be more easily influenced by temperature changes in the laboratory. We have shown that there is good correlation between the shift in the precursor ion mass and the ambient temperature. Other studies carried out to investigate the effects on mass peak shape and response (both in the SIM and SRM mode) as the result of varying the FWHM revealed some interesting results. For instance, the decrease in response with the decrease in the FWHM was larger using SRM compared to that using SIM. However, the decrease in both SRM and SIM response with decreasing FWHM was significantly smaller compared with the decrease obtained using an older generation instrument. We demonstrate that, at concentrations near the limit of detection, the signal specificity can be improved by using an enhanced resolution method. To compare the performance of an enhanced resolution method against a unit resolution method under optimized mass spectrometric conditions, we analyzed calibration standards and quality control samples using a lower limit of quantitation that could be easily achieved by either method. Under these conditions, the two methods were essentially the same, demonstrating that the enhanced resolution method is as accurate, precise and rugged as the unit resolution method. We propose system suitability procedures, based on precursor ion scan, product ion scan, SRM with fractional mass changes, or SIM with a narrow scan width, for the updating of the SRM set masses before the start of analysis. We also recommend that Q1 SRM masses be determined during and at the end of analysis in order to ascertain whether or not the precursor masses have shifted during the course of the analysis.

Chromatography, Liquid↗

Miniature cylindrical ion trap mass spectrometer.

A miniature cylindrical ion trap mass spectrometer is described, and preliminary data are presented. Functionality and performance of laboratory-scale instruments have been maintained to the extent possible in this battery-operated mass spectrometer. Capabilities include tandem mass spectrometry experiments. Custom-designed electronic components include the RF scanning and amplification system, data acquisition components, and lens power supplies, as well as a custom-software application. Direct leak and membrane introduction inlet systems are used for sample introduction. A mass/charge range of approximately 250 Th with unit mass resolution has been demonstrated.

Journal Article↗

A strategy for a post-method-validation use of incurred biological samples for establishing the acceptability of a liquid chromatography/tandem mass-spectrometric method for quantitation of drugs in biological samples.

Validated liquid chromatography/tandem mass spectrometric (LC/MS/MS) methods are now widely used for quantitation of drugs in post-dose (incurred) biological samples for the assessment of pharmacokinetic parameters, bioavailability and bioequivalence. In accordance with the practice currently accepted within the pharmaceutical industry and the regulatory bodies, validation of a bioanalytical LC/MS/MS method is performed using standards and quality control (QC) samples prepared by spiking the drug (the analyte) into the appropriate blank biological matrix (e.g. human plasma). The method is then declared to be adequately validated for analyzing incurred biological samples. However, unlike QC samples, incurred samples may contain an epimer or another type of isomer of the drug, such as a Z or E isomer. Such a metabolite will obviously interfere with the selected reaction monitoring (SRM) transition used for the quantitation of the drug. The incurred sample may also contain a non-isomeric metabolite having a molecular mass different from that of the drug (such an acylglucuronide metabolite) that can still contribute to (and hence interfere with) the SRM transition used for the quantitation of the drug. The potential for the SRM interference increases with the use of LC/MS/MS bioanalytical methods with very short run times (e.g. 0.5 min). In addition, a metabolite can potentially undergo degradation or conversion to revert back to the drug during the multiple steps of sample preparation that precede the introduction of the processed sample into the LC/MS/MS system. In this paper, we recommend a set of procedures to undertake with incurred samples, as soon as such samples are available, in order to establish the validity of an LC/MS/MS method for analyzing real-life samples. First, it is recommended that the stability of incurred samples be investigated 'as is' and after sample preparation. Second, it is recommended that potential SRM interference be investigated by analyzing the incurred samples using the same LC/MS/MS method but with the additional incorporation of the SRM transitions attributable to putative metabolites (multi-SRM method). The metabolites monitored will depend on the expected metabolic products of the drug, which are predictable based on the functional groups present in the chemical structure of the drug. Third, it is recommended that potential SRM interference be further investigated by analyzing the incurred samples using the multi-SRM LC/MS/MS method following the modification of chromatographic conditions to enhance chromatographic separation of the drug from any putative metabolites. We will demonstrate the application of the proposed strategy by using a carboxylic acid containing drug candidate and its acylglucuronide as a putative metabolite. Plasma samples from the first-in-man (FIM) study of the drug candidate were used as the incurred samples.

Animals↗