PubMed Health⌕ Search

Biomedical subjects

Zhenghui Zhang

Publications and source records attributed to Zhenghui Zhang.

4 recordsLinked to original sources

Decomposed direct matrix inversion for fast non-cartesian SENSE reconstructions.

A new k-space direct matrix inversion (DMI) method is proposed here to accelerate non-Cartesian SENSE reconstructions. In this method a global k-space matrix equation is established on basic MRI principles, and the inverse of the global encoding matrix is found from a set of local matrix equations by taking advantage of the small extension of k-space coil maps. The DMI algorithm's efficiency is achieved by reloading the precalculated global inverse when the coil maps and trajectories remain unchanged, such as in dynamic studies. Phantom and human subject experiments were performed on a 1.5T scanner with a standard four-channel phased-array cardiac coil. Interleaved spiral trajectories were used to collect fully sampled and undersampled 3D raw data. The equivalence of the global k-space matrix equation to its image-space version, was verified via conjugate gradient (CG) iterative algorithms on a 2x undersampled phantom and numerical-model data sets. When applied to the 2x undersampled phantom and human-subject raw data, the decomposed DMI method produced images with small errors (< or = 3.9%) relative to the reference images obtained from the fully-sampled data, at a rate of 2 s per slice (excluding 4 min for precalculating the global inverse at an image size of 256 x 256). The DMI method may be useful for noise evaluations in parallel coil designs, dynamic MRI, and 3D sodium MRI with fixed coils and trajectories.

Algorithms↗

Spatial domain method for the design of RF pulses in multicoil parallel excitation.

Parallel excitation has been introduced as a means of accelerating multidimensional, spatially-selective excitation using multiple transmit coils, each driven by a unique RF pulse. Previous approaches to RF pulse design in parallel excitation were either formulated in the frequency domain or restricted to echo-planar trajectories, or both. This paper presents an approach that is formulated as a quadratic optimization problem in the spatial domain and allows the use of arbitrary k-space trajectories. Compared to frequency domain approaches, the new design method has some important advantages. It allows for the specification of a region of interest (ROI), which improves excitation accuracy at high speedup factors. It allows for magnetic field inhomogeneity compensation during excitation. Regularization may be used to control integrated and peak pulse power. The effects of Bloch equation nonlinearity on the large-tip-angle excitation error of RF pulses designed with the method are investigated, and the utility of Tikhonov regularization in mitigating this error is demonstrated.

Algorithms↗

High temporal and spatial resolution 4D MRA using spiral data sampling and sliding window reconstruction.

Contrast-enhanced magnetic resonance angiography (CE-MRA) requires high spatial resolution to demonstrate detailed vasculature and high temporal resolution to capture the contrast bolus. Sparse bright voxels in MRA permit substantial undersampling in MRI data acquisition, allowing simultaneous high temporal and spatial resolution. We developed a time-resolved 3D MRA technique using the efficient spiral sampling trajectory, and performed off-resonance corrections using inhomogeneity field maps. View sharing and sliding window reconstruction were utilized to generate high temporal resolution. High-resolution 3D angiograms were generated at 1-2 s per frame, with a 5-8 ml gadolinium dose, in patients with vascular disease.

Arteriosclerosis↗

Self-calibrated spiral SENSE.

Current standard sensitivity-encoded parallel imaging (SENSE) utilizes a fully sampled low-resolution reference scan to estimate the coil sensitivities. This reference scan adds scan time and may introduce misregistration artifacts. The purpose of this study was to investigate the feasibility of estimating the coil sensitivities for spiral SENSE directly from an undersampled k-space center. The limited spatial frequencies of the coil sensitivities, and the undersampling beyond the Nyquist radius cause image artifacts. A point spread function (PSF) analysis and experiments on both phantoms and humans identified an optimal radius for the k-space center by minimizing these image artifacts. The preliminary data indicate that self-calibrated SENSE is as accurate as standard SENSE, which uses a fully sampled reference scan.

Algorithms↗