PubMed Health⌕ Search

Biomedical subjects

Zhiai Xu

Publications and source records attributed to Zhiai Xu.

6 recordsLinked to original sources

A novel alcohol dehydrogenase biosensor based on solid-state electrogenerated chemiluminescence by assembling dehydrogenase to Ru(bpy)(3)2+-Au nanoparticles aggregates.

Based on electrogenerated chemiluminescence (ECL), a novel method for fabrication of alcohol dehydrogenase (ADH) biosensor by self-assembling ADH to Ru(bpy)(3)(2+)-AuNPs aggregates (Ru-AuNPs) on indium tin oxide (ITO) electrode surface has been developed. Positively charged Ru(bpy)(3)(2+) could be immobilized stably on the electrode surface with negatively charged AuNPs in the form of aggregate via electrostatic interaction. On the other hand, AuNPs are favourable candidates for the immobilization of enzymes because amine groups and cysteine residues in the enzymes are known to bind strongly with AuNPs. Moreover, AuNPs can act as tiny conduction centers to facilitate the transfer of electrons. Such biosensor combined enzymatic selectivity with the sensitivity of ECL detection for quantification of enzyme substrate, and it displayed wide linear range, high sensitivity and good stability.

Alcohol Dehydrogenase↗

Biopolymer and carbon nanotubes interface prepared by self-assembly for studying the electrochemistry of microperoxidase-11.

Stable films of biopolymer chitosan and carbon nanotubes were prepared by a layer-by-layer self-assembly technique. Atomic force microscopy, scanning electron microscopy, cyclic voltammetry, and UV-vis spectroscopy were used to characterize the film assembly. Atomic force microscopy and scanning electron microscopy showed that an even, stable film was formed. The UV-vis spectroscopy and cyclic voltammetry study indicated the uniform growth of the film. The property of the self-assembled multilayer film in promoting protein electron transfer was demonstrated by incorporating microperoxidase-11 in the film. Microperoxidase-11 in the multilayer film could transfer electrons with the electrode indicating that carbon nanotubes could wire the protein to the electrode. The electrocatalytic activity of the microperoxidase-11 containing multilayer film-modified electrode toward H(2)O(2) and O(2) was investigated. The results showed that along with the increase in the assembled layers the electrocatalytic reduction potentials of H(2)O(2) and O(2) shifted positively. The prepared multilayer film of chitosan and carbon nanotubes containing protein was a sensitive interface for electrocatalytic study.

Biopolymers↗

Small molecules as cross-linkers: fabrication of carbon nanotubes/thionine self-assembled multilayers on amino functionalized surfaces.

Electroactive and photoactive thionine molecules have been selected as cross-linkers to construct self-assembled multilayers containing carbon nanotubes (CNTs)via the alternate layer deposition technique. The resulting multilayer system can electrocatalyze the oxidation of NADH and offer potential applications in other fields such as biosenors and photovoltaic devices.

Journal Article↗

The direct electron transfer of glucose oxidase and glucose biosensor based on carbon nanotubes/chitosan matrix.

The glucose oxidase (GOD) is entrapped in the composite of carbon nanotubes/chitosan and direct electron transfer reaction between GOD and electrode takes place. The electron transfer rate of GOD is greatly enhanced to 7.73 s(-1) in the system, which is more than one-fold higher than that of flavin adenine dinucleotide adsorbed on the carbon nanotubes (3.1 s(-1)). This maybe results from the conformational change of GOD in the microenvironment enabling the accessibility of active site for GOD to the electrode. Additionally, the bioactivity of GOD modified in the composite on electrode surface is kept. So as-prepared electrode can be used as a glucose biosensor exhibiting higher sensitivity (0.5 microA mM(-1)) and better stability. The facile procedure of immobilizing GOD will promote the developments of electrochemical research for protein, biosensors and other bioelectrochemical devices.

Adsorption↗

Electrogenerated chemiluminescence biosensor with alcohol dehydrogenase and tris(2,2'-bipyridyl)ruthenium (II) immobilized in sol-gel hybrid material.

An ethanol biosensor based on electrogenerated chemiluminescence detection was developed. Electrogenerated chemiluminescence reagent tris(2,2'-bipyridyl)ruthenium (II) and alcohol dehydrogenase were immobilized in the same sol-gel hybrid film. The copolymer poly(vinyl alcohol) with 4-vinylpyridine and cation exchanger Nafion were incorporated into sol-gel film to provide the microenvironment for retaining the activity of enzyme and immobilize tris(2,2'-bipyridyl)ruthenium (II). The design was simpler than the previous two-layer format. The experimental conditions, such as scan rate, pH and concentration of the cofactor were investigated. The intensity of electrogenerated chemiluminescence increased linearly with ethanol concentration from 2.5x10(-5) to 5.0x10(-2) M and detection limit was 1.0x10(-5) M. The prepared biosensor exhibited high sensitivity, wide linear range and good stability.

2,2'-Dipyridyl↗

Single-wall carbon nanotube-based voltammetric sensor and biosensor.

The pH-sensitive property of the single-wall carbon nanotube modified electrode based on the electroactive group on the single-wall carbon nanotube was explored by differential pulse voltammetry technique. In pH range 1-13 investigated in Britton-Robinson (B-R) buffer, the anodic peak shifted negatively along with the increase of pH exhibiting a reversible Nernstian response. Experiments were carried out to investigate the response of the single-wall carbon nanotube (SWNT) modified electrode to analytes associated with pH change. The response behavior of the modified electrode to ammonia was studied as an example. The potential response could reach equilibrium within 5 min. The modified electrode had good operational stability. Voltammetric urease and acetylcholinesterase biosensors were constructed by immobilizing the enzymes with sol-gel hybrid material. The maximum potential shift could reach 0.130 and 0.220 V for urea and acetylthiocholine, respectively. The methods for preparing sensor and biosensor were simple and reproducible and the range of analytes could be extended to substrates of other hydrolyases and esterases. This broadened the biosensor application of carbon nanotube in electrochemical area.

Acetylcholine↗