Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump.

The CentriMag centrifugal blood pump is a newly developed ventricular assist device based on magnetically levitated bearingless rotor technology. A combined computational and experimental study was conducted to characterize the hemodynamic and hemocompatibility performances of this novel blood pump. Both the three-dimensional flow features of the CentriMag blood pump and its hemolytic characteristics were analyzed using computational fluid dynamics (CFD)-based modeling. The hydraulic pump performance and hemolysis level were quantified experimentally. The CFD simulation demonstrated a clean and streamlined flow field in the main components of the CentriMag blood pump. The predicted results by hemolysis model indicated no significant high shear stress regions in the pump. A comparison of CFD predictions and experimental results showed good agreements. The relatively large gap passages (1.5 mm) between the outer rotor walls and the lower housing cavity walls provide a very good surface washing through a secondary flow path while the shear stresses in the secondary flow paths are reduced, resulting in a low rate of hemolysis ([Normalized Index of Hemolysis] NIH = 0.0029 +/- 0.006) without a decrease of the pump's hydrodynamic performance (pressure head: 352 mm Hg at a flow rate of 5.0 L/min and a rotational speed of 4,000 rpm).

Biomedical Engineering↗

Microscopic investigation of erythrocyte deformation dynamics.

The understanding of erythrocyte deformation under conditions of high shear stress and short exposure time is central to the study of hemorheology and hemolysis within prosthetic blood contacting devices. A combined computational and experimental microscopic study was conducted to investigate the erythrocyte deformation and its relation to transient stress fields. A microfluidic channel system with small channels fabricated using polydimethylsiloxane on the order of 100 mum was designed to generate transient stress fields through which the erythrocytes were forced to flow. The shear stress fields were analyzed by three-dimensional computational fluid dynamics. Microscopic images of deforming erythrocytes were experimentally recorded to obtain the changes in cell morphology over a wide range of fluid dynamic stresses. The erythrocyte elongation index (EI) increased from 0 to 0.54 with increasing shear stress up to 123 Pa. In this shear stress range, erythrocytes behaved like fluid droplets, and deformed and flowed following the surrounding fluid. Cells exposed to shear stress beyond 123 Pa (up to 5170 Pa) did not exhibit additional elongation beyond EI=0.54. Two-stage deformation of erythrocytes in response to shear stress was observed: an initial linear elongation with increasing shear stress and a plateau beyond a critical shear stress.

Animals↗

Progress toward an ambulatory pump-lung.

OBJECTIVES: Currently available therapies for acute and chronic lung diseases have not been effective and have various problems associated with the technologies used. We present a novel active mixing pump-lung with the goal of providing total respiratory support to ambulatory patients. METHODS: The pump-lung is based on the concept of active mixing oxygenation within a constrained vortex. The rotation of hollow-fiber membranes disrupts the concentration boundary layer, increasing gas exchange efficiency, and simultaneously pumps the blood. Consequently, the amount of membranes required to achieve gas transfer sufficient for total respiratory support is considerably small. A series of studies, including computational design, experimental bench testing, and in vivo animal experiments, have been performed to implement this concept into a viable artificial pump-lung device. RESULTS: A series of pump-lung prototypes with a membrane surface area of 0.17 to 0.5 m2 were designed and characterized in vitro with bovine blood, demonstrating extremely high gas exchange efficiency. The prototype with a gas exchange surface area of 0.5 m2 was evaluated in calves. The device provided oxygen transfer of approximately 115 mL/min for respiratory support of an animal for up to 5 days. CONCLUSIONS: Progress to date suggests a high likelihood of success for an extracorporeal shorter-term lung that can be switched in and out like dialysis devices. Our device is unique in that it incorporates an integrated pumping and active mixing principle for excellent gas transfer and eliminates the need of the native right ventricle's ability to power blood through the artificial and natural lungs.

Animals↗

Design and hydrodynamic evaluation of a novel pulsatile bioreactor for biologically active heart valves.

Biologically active heart valves (tissue engineered and recellularized tissue-derived heart valves) have the potential to offer enhanced function when compared to current replacement value therapies since they can possibly remodel, and grow to meet the needs of the patient, and not require chronic medication. However, this technology is still in its infancy and many fundamental questions remain as to how these valves will function in vivo. It has been shown that exposing biologically active tissue constructs to pulsatile pressures and flows during in vitro culture produces enhanced extracellular matrix protein expression and cellularity, although the ideal hydrodynamic conditioning regime is as yet unknown. Moreover, in vitro organ-level studies of living heart valves aimed at studying the remodeling processes require environments that can accurately reproduce in vivo hemodynamics under sterile conditions. To this end, we have developed a system to study the effects of subjecting biologically active heart valves to highly controlled pulsatile pressure and flow waveforms under sterile conditions. The device fits inside a standard incubator and utilizes a computer-controlled closed loop feedback system to provide a high degree of control. The mean pressure, mean flow rate, driving frequency, and shape of the pulsatile pressure waveform can be changed automatically in order to simulate both physiologic and nonphysiologic hemodynamic conditions. Extensive testing and evaluation demonstrated the device's ability to subject a biologically active heart valve to highly controlled pulsatile waveforms that can be modulated during the course of sterile incubation.

Bioprosthesis↗

Blood soluble drag-reducing polymers prevent lethality from hemorrhagic shock in acute animal experiments.

Over the past several decades, blood-soluble drag reducing polymers (DRPs) have been shown to significantly enhance hemodynamics in various animal models when added to blood at nanomolar concentrations. In the present study, the effects of the DRPs on blood circulation were tested in anesthetized rats exposed to acute hemorrhagic shock. The animals were acutely resuscitated either with a 2.5% dextran solution (Control) or using the same solution containing 0.0005% or 5 parts per million (ppm) concentration of one of two blood soluble DRPs: high molecular weight (MW=3500 kDa) polyethylene glycol (PEG-3500) or a DRP extracted from Aloe vera (AVP). An additional group of animals was resuscitated with 0.0075% (75 ppm) polyethylene glycol of molecular weight of 200 kDa (PEG-200), which possesses no drag-reducing ability. All of the animals were observed for two hours following the initiation of fluid resuscitation or until they expired. We found that infusion of the DRP solutions significantly improved tissue perfusion, tissue oxygenation, and two-hour survival rate, the latter from 19% (Control) and 14% (PEG-200) to 100% (AVP) and 100% (PEG-3500). Furthermore, the Control and PEG-200 animals that survived required three times more fluid to maintain their blood pressure than the AVP and PEG-3500 animals. Several hypotheses regarding the mechanisms underlying these observed beneficial hemodynamic effects of DRPs are discussed. Our findings suggest that the drag-reducing polymers warrant further investigation as a potential clinical treatment for hemorrhagic shock and possibly other microcirculatory disorders.

Acute Disease↗