PubMed Health⌕ Search

Biomedical subjects

Zi-qiao Lei

Publications and source records attributed to Zi-qiao Lei.

3 recordsLinked to original sources

[Multi-slice spiral CT imaging in the post-operative assessment of cochlear implanted electrode].

OBJECTIVE: To evaluate the usefulness of multi-slice spiral CT (MSCT) in the post-operative assessment of cochlear implanted electrode. METHODS: Twenty-three cochlear implant recipients were enrolled in this study. All patients were examined with a SOMATOM Sensation 16-slice CT scanner (Siemens) using the following parameters: 120 kV, 100 mAs, 0. 75 mm collimation, 1 mm reconstruction slice thickness and increment, a pitch factor of 1, and a FOV of 100 mm. The axial images of interested ears were reconstructed with 0.1 mm increment and a FOV of 50 mm, and then volume rendering technique (VRT) reconstruction were done on the work station. RESULTS: The electrode arrays were detected on axial CT images. Both inner ear and electrode array could be displayed on one image simultaneously. VRT provided an intuitionistic view of the relationship between electrode array and cochlea VRT showed the number of the electrode array in 20 patients implanted with Combi 40 + standard electrode array and demonstrated the shape, position, and insertion depth. The electrode array number determined by VRT was in accordance with the surgical findings in 18 patients, and was underestimated in two patients. In 3 patients with Combi 40 + compressed electrode array, only 4 to 5 electrodes arrays were clearly identified and others were not observed. CONCLUSION: MSCT with VRT can provide useful three-dimensional information of the electrode array and indicate the exact relationship between electrode array and cochlea.

Adolescent↗

[Application of multi-slice spiral CT angiography after endoluminal exclusion of aortic diseases].

OBJECTIVE: To study the application of multi-slice spiral CT angiography (MSCTA) after endoluminal exclusion of aortic diseases. METHODS: 16-slice CT angiography was performed in 15 patients with aortic dissection and 4 patients with aortic aneurysm after endovascular exclusion. Two observers analysed the images and interpreted the outcomes and complications after endovascular exclusions of aortic dissection and aortic aneurysm. RESULTS: In 19 patients, thrombus was found in all the false lumens of aortic dissection and the outer-stent cavity of aortic aneurysm. However, one patient with aortic aneurysm graft thrombosis; 4 patients had endo-leak (3 with type I endo-leak, 1 with type III endo-leak complicating graft deformation); one achieved perfusion recovery, and one experienced thrombolysis of superior mesenteric artery. CONCLUSION: MSCTA can be an objective tool for the post-operative evaluation of endovascular exclusion of aortic diseases.

Adult↗

Using quantitative CT to predict postoperative pulmonary function in patients with lung cancer.

BACKGROUND: At present, the therapy for patients with lung cancer that achieves a high rate of cure is surgical resection at an early stage of the disease. The aim of this study is to evaluate quantitative computed tomography (QCT) for predicting postoperative pulmonary function in patients with lung cancer. METHODS: The data of thirty-one patients with lung cancer who underwent both pulmonary functional tests and QCT scan before operations were collected. A CT program was used to quantify the volume of whole lung parenchyma with attenuation of -910 HU to -600 HU, which was defined as total functional lung volume (TFLV). Similarly, the volume of lung (lobes or segments) with attenuation of -910 HU to -600 HU was defined as regional functional lung volume (RFLV). Forced vital capacity (FVC), forced expiratory volume in first second (FEV1), FVC% and FEV1% (ratio to reference values of the matched population) were obtained from preoperational pulmonary functional tests. According to the formula: predicted FVC (pre-FVC) = preoperative FVC x [1-(RFLV/TFLV)]; predicted FEV1 (pre-FEV1) = preoperative FEV1 x [1-(RFLV/TFLV)], we obtained values of predicted FVC, predicted FEV1, predicted FVC% (pre-FVC/reference values of the matched population), and predicted FEV1% (pre-FEV1/reference values of the matched population). The paired t test and Pearson correlation test were used to assess significance of differences and correlations between CT predicted values and postoperative measured results of FVC, FEV1, FVC% and FEV1%. RESULTS: QCT predicted values correlated well with postoperative FVC, FEV1, FVC% and FEV1% (r = 0.873, 0.809, 0.849 and 0.801 respectively, all P < 0.01). CONCLUSIONS: QCT is an effective and accurate way to predict postoperative pulmonary function in patients undergoing pulmonary resection, regardless of the patients' preoperative pulmonary functional status.

Female↗