PubMed Health⌕ Search

Biomedical subjects

Zigang Ge

Publications and source records attributed to Zigang Ge.

8 recordsLinked to original sources

Mechanical dissociation of human embryonic stem cell colonies by manual scraping after collagenase treatment is much more detrimental to cellular viability than is trypsinization with gentle pipetting.

Because hESC (human embryonic stem cells) are 'social cells' that require co-operative interactions and intimate physical contact with each other, it is absolutely essential to dissociate hESC colonies into cellular clumps rather than into a single-cell suspension during serial passage. The present study compared two commonly used protocols for dissociating hESC colonies. The first protocol involved mild enzymatic treatment with collagenase type IV (1 mg/ml) for approx. 5-10 min, prior to mechanical dissociation into cellular clumps through manual scraping with a plastic pipette tip. The second protocol involved a short duration of exposure (2-3 min) to low concentrations of trypsin (0.05%), followed by gentle pipetting. The MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide] assay was used to compare the recovery of viable cells after dissociating hESC colonies with these two protocols, before and after conventional freeze-thawing with 10% (v/v) DMSO. Besides undifferentiated hESC, the randomly differentiated fibroblastic progenies of hESC at various passages (P0-P4), together with an immortalized cell line (CRL-1486), were also utilized to compare the two protocols. The results demonstrated that the second protocol (trypsinization with gentle pipetting) is much less detrimental to cellular viability than is the first protocol (collagenase treatment with scratching). This in turn translated to higher freeze-thaw survival rates. It is hypothesized that scratching after collagenase treatment (first protocol) somehow induces physical damage to the cells, thereby leading to a lower recovery of viable cells, both before and after freeze-thawing.

Cell Culture Techniques↗

Biomaterials and scaffolds for ligament tissue engineering.

Tissue engineering has achieved much progress in an attempt to improve and recover impaired functions of tissues and organs. Although many studies have been done, progress for tissue-engineered anterior cruciate ligaments (ACLs) has been slow due to their complex structures and mechanical properties. In this review, the ACL anatomical structure, progresses achieved, material selection, structure design, and future direction have been discussed, while the challenges and requirements from materials and scaffolds are highlighted. There is a considerably huge amount work that needs to be carried out; as such, future direction in ligament tissue engineering is proposed in hope that this review will give information on future ligament tissue engineering.

Biocompatible Materials↗

Efficacy of bone marrow-derived stem cells in strengthening osteoporotic bone in a rabbit model.

Osteoporosis might be due to defects in mesenchymal stem cells (MSCs) that lead to reduced proliferation and osteoblast differentiation. We hypothesized that transplantation of MSCs into sites at risk for developing osteoporotic bone could improve bone structure and biomechanics. The aim of this study was to establish an osteoporosis rabbit model by ovariectomy (OVX), characterize the autologous MSCs from the OVX rabbits, and transplant the autologous MSCs into the OVX rabbits. MSCs harvested from bone marrow of normal and OVX rabbits were culture expanded and differentiated in osteogenic medium. Phenotypes were evaluated by collagen I immunostaining, von Kossa staining, and quantitative assays of bone-specific alkaline phosphatase (B-ALP) and osteocalcin (OCN). MSCs were transfected with green fluorescence protein (GFP) and implanted in the gluteus muscle to trace their fate in vivo. Cultured autologous MSCs from OVX rabbits were constructed in calcium alginate gels and then transplanted in the distal femurs. At 4 and 8 weeks after implantation, histomorphometrical and biomechanical analyses were performed on the samples. MSCs from OVX rabbits displayed higher B-ALP activity, but had similar OCN levels as compared to those from sham rabbits. After 8 weeks of implantation, more bone apposition was found in the MSC-alginate-treated group. Histomorphometry indicated increased trabecular thickness. Histology also illustrated improved microstructures with newly formed osteoids and enhanced trabecular thickness. In addition, biomechanical testing revealed stronger stiffness in the MSC-alginate treatment group. Therefore, this study implies that transplantation of MSCs can help to strengthen osteoporotic bone in rabbits.

Animals↗

Loss of viability during freeze-thaw of intact and adherent human embryonic stem cells with conventional slow-cooling protocols is predominantly due to apoptosis rather than cellular necrosis.

A major challenge in the widespread application of human embryonic stem (hES) cells in clinical therapy and basic scientific research is the development of efficient cryopreservation protocols. Conventional slow-cooling protocols utilizing standard cryoprotectant concentrations i.e. 10% (v/v) DMSO, yield extremely low survival rates of <5% as reported by previous studies. This study characterized cell death within frozen-thawed hES colonies that were cryopreserved under standard conditions. Surprisingly, our results showed that immediately after post-thaw washing, the overwhelming majority of hES cells were viable (approximately 98%), as assessed by the trypan blue exclusion test. However, when the freshly-thawed hES colonies were incubated within a 37 degrees C incubator, there was observed to be a gradual reduction in cell viability over time. The kinetics of cell death was drastically slowed-down by keeping the freshly-thawed hES colonies at 4 degrees C, with >90% of cells remaining viable after 90 min of incubation at 4 degrees C. This effect was reversible upon re-exposing the cells to physiological temperature. The vast majority of low temperature-exposed hES colonies gradually underwent cell death upon incubation for a further 90 min at 37 degrees C. Terminal deoxynucleotidyl transferase (TdT)-mediated dUTP nick-end-labeling (TUNEL) assay confirmed apoptosis-induced nuclear DNA fragmentation in frozen-thawed hES cells after incubation at 37 degrees C for 90 min. Expression of active caspase-3 enzyme, which is another prominent marker of apoptosis, was confirmed by immunocytochemical staining, while transmission electron microscopy showed typical ultrastructural features of apoptosis such as chromatin condensation and margination to the nuclear membrane. Hence, our results demonstrated that apoptosis instead of cellular necrosis, is the major mechanism of the loss of viability of cryopreserved hES cells during freeze-thawing with conventional slow-cooling protocols.

Apoptosis↗

The effects of bone marrow-derived mesenchymal stem cells and fascia wrap application to anterior cruciate ligament tissue engineering.

After an anterior cruciate ligament (ACL) injury, surgical reconstructions are necessary in most cases, either with autografts, allografts, or artificial ligaments. Potential tissue-engineered ligaments would circumvent the disadvantages apparent in these methods. While seeding of mesenchymal stem cells (MSCs) and fascia wrap could potentially improve tissue regeneration and mechanical properties, their exact roles were evaluated in the current study. Knitted biodegradable scaffolds of poly-L-lactic acid (PLLA) and poly-glycolic-lactic acid (PGLA) yarns were used to reconstruct ACL in 48 rabbits. These were divided into four equal groups: only knitted scaffolds were used in group I; knitted scaffolds and mesenchymal stem cells were used in group II; knitted scaffolds, MSCs, and fascia lata were used in group III; knitted scaffolds and fascia lata were used in group IV. Carboxyfluorescein diacetate (CFDA)-labeled MSCs were used to trace the fate of seeded cells in groups II and III. Histology, Western blot analysis, and mechanical properties of reconstructed ACL were analyzed after 20 weeks. Fibroblast ingrowths were seen in all four groups while CFDA-labeled MSCs could be found after 8 weeks of implantation in groups II and III. Both the amount of collagen type I and collagen type III in groups III and IV were significantly higher than in group II, which was much higher than in group I. Both maximal tensile loads and stiffness of the reconstructed ACLs in groups I, II, III, and IV were significantly lower than normal controls after 20 weeks of implantation. It is concluded that MSCs could promote synthesis of collagen type I and collagen type III in tissue-engineered ligaments, while fascia wraps have stronger effects. Both MSC seeding and fascia wrap could not enhance ultimate tensile load and stiffness.

Animals↗

Selection of cell source for ligament tissue engineering.

Use of appropriate types of cells could potentially improve the functionality and structure of tissue engineered constructs, but little is known about the optimal cell source for ligament tissue engineering. The object of this study was to determine the optimal cell source for anterior cruciate ligament (ACL) tissue engineering. Fibroblasts isolated from anterior cruciate ligament, medial collateral ligament (MCL), as well as bone marrow mesenchymal stem cells (MSC) were compared using the following parameters: proliferation rate, collagen excretion, expression of collagen type I, II, and III, as well as alpha-smooth muscle actin. Green fluorescent protein (GFP) transfected MSCs were used to trace their fate in the knee joints. MSC, ACL, and MCL fibroblasts were all highly stained with antibodies for collagen types I and III and alpha-smooth muscle actin while negatively stained with collagen type II. Proliferation rate and collagen excretion of MSCs were higher than ACL and MCL fibroblasts (p < 0.05), and MSCs could survive for at least 6 weeks in knee joints. In summary, MSC is potentially a better cell source than ACL and MCL fibroblasts for anterior cruciate ligament tissue engineering.

Animals↗

Hydroxyapatite-chitin materials as potential tissue engineered bone substitutes.

Hydroxyapatite (HA) in 25%, 50% and 75% w/w fractions was incorporated into chitin solutions and processed into air- and freeze-dried materials. These HA-chitin materials were exposed to cell cultures and implanted into the intramusculature of a rat model. The HA-chitin materials were found to be non-cytotoxic and degraded in vivo. The presence of the HA filler enhanced calcification as well as accelerated degradation of the chitin matrix. The freeze-dried HA-chitin matrixes were selected for further cell seeding experiments because of their porous nature. Mesenchymal stem cells harvested from NZW rabbits were induced into osteoblasts in vitro using dexamethasone. These osteoblasts were cultured for 1 week, statically loaded onto the porous HA-chitin matrixes and implanted into bone defects of the rabbit femur for 2 months. Histology of explants showed bone regeneration with biodegradation of the HA-chitin matrix. Similarly, green fluorescence protein (GFP) transfected MSC-induced osteoblasts were also loaded onto porous HA-chitin matrixes and implanted into the rabbit femur. The results from GFP-transfected MSCs showed that loaded MSCs-induced osteoblasts did not only proliferate but also recruited surrounding tissue to grow in. This study demonstrates the potential of HA-chitin matrixes as a good substrate candidate for tissue engineered bone substitute.

Animals↗