Errors in retinal thickness measurements obtained by optical coherence tomography.

OBJECTIVE: To report the frequency and severity of optical coherence tomography (OCT) retinal thickness measurement errors and to describe parameters that predict these errors. DESIGN: Observational case series. PARTICIPANTS: Two hundred consecutive patients undergoing OCT imaging. METHODS: One eye (primary) from each of 200 consecutive patients undergoing Stratus OCT imaging (Carl Zeiss Meditec, Dublin, CA) with radial lines or fast macular thickness-based acquisition protocols was selected for review by 2 graders. On each of the line scans, graders evaluated the position of the automated retinal boundary lines (inner retinal surface and retinal pigment epithelium band) used by the OCT machine for thickness calculations and graded the positioning on a 6-point subjective, categorical error scale to generate an error score. The presence of thickness errors was correlated with various parameters, including the analysis confidence assessment reported by the OCT software, disease diagnosis, retinal morphologic features, the foveal center thickness standard deviation (FCTSD), and the FCTSD-to-foveal center thickness (FCT) ratio. MAIN OUTCOME MEASURE: Average OCT retinal thickness error score. RESULTS: Errors of retinal boundary detection and thickness measurement were observed in 92% of eyes, but were severe in only 13.5% of eyes. The identification of an error or low analysis confidence by the OCT software was strongly associated with the severity of the retinal thickness errors. A higher FCTSD-to-FCT ratio and presence of subretinal fluid also were associated with more severe errors. Retinal cysts and a diagnosis of retinal vascular disease such as diabetic macular edema were less likely to be associated with significant errors. CONCLUSIONS: Retinal thickness measurement errors occur frequently with current OCT segmentation and analysis algorithms. Severe errors are more frequent in eyes with subretinal pathologic features, but generally are detected by the OCT software. A high FCTSD-to-FCT ratio (>0.1) also may alert the clinician to the possibility of thickness errors. Clinical studies, particularly those pertaining to subretinal diseases, should consider these errors when incorporating OCT imaging in the study design.

Diagnostic Errors↗

Axial length: a risk factor for cataractogenesis.

INTRODUCTION: To evaluate whether eyes with longer axial lengths are associated more often with clinically significant cataracts than eyes with shorter axial lengths. MATERIAL AND METHODS: Charts of consecutive patients who underwent cataract surgery by 4 resident surgeons at Los Angeles County Hospital from July 2001 through May 2002 were retrospectively reviewed. Those patients whose axial lengths were significantly different between the 2 eyes (>or=0.30 mm) and who had no pathology (other than cataracts) affecting visual acuity were included in the study. The 2 eyes in each patient were compared for preoperative best-corrected visual acuity and severity of cataracts. RESULTS: Thirty-four of 353 patients had interocular axial length differences of at least 0.3 mm and were included in this study. Thirty-one patients had worse, 1 had equal, and 2 had better preoperative vision in the eye with longer versus the shorter axial length. Fourteen patients had more severe, 11 had the same, and 1 had less severe posterior subcapsular cataract (PSC) in the eye with longer axial length. In 8 patients, PSC severity could not be assessed due to obscuring nuclear sclerosis. Twenty-four patients had more severe, 7 patients had equal, and 3 patients had less severe nuclear sclerosis in the longer eye. Overall, longer axial lengths correlated with worse visual acuity, posterior subcapsular cataracts, and nuclear sclerosis. Diabetic status did not affect the correlation. The correlations were stronger with greater axial length asymmetry. CONCLUSIONS: Eyes with longer axial lengths have a higher prevalence of cataracts.

Cataract↗

Fungal keratitis caused by Scedosporium apiospermum: report of two cases and review of treatment.

PURPOSE: We report our experience in treating two cases of Scedosporium apiospermum keratitis and provide a review of basic scientific and clinical data regarding the treatment of this visually devastating disease. METHOD: We present a case report and literature review. RESULTS: A 35-year-old woman and a 73-year-old man both reported pain, redness, and a foreign body sensation in the eye after trauma. They were initially treated with antibacterials. When cultures were positive for S. apiospermum, the first patient was treated with fluconazole and amphotericin with good results. The second was treated with fluconazole and natamycin, but the infection persisted and the eye was eventually enucleated. Review of the literature showed variable responsiveness of S. apiospermum to antifungal treatment. CONCLUSIONS: It is difficult to predict how S. apiospermum keratitis will respond to treatment, but miconazole appears to be useful in conjunction with other antifungals. Voriconazole shows promise as an effective alternative.

Adult↗