High-Plex Tissue Imaging with Conventional Immunofluorescence Platforms and Open-Source Software via Iterative Bleaching Extends Multiplexity (IBEX).

Iterative bleaching extends multiplexity (IBEX) is an easy-to-use, highly multiplex immunofluorescent tissue imaging method that employs widely available microscopy platforms, commercial reagents, and open-source software. In this article, we describe how to implement this method in a laboratory that has minimal experience with immunohistochemistry.

Software↗

Precise robot-assisted guide positioning for distal locking of intramedullary nails.

This paper presents a novel image-guided robot-based system to assist orthopedic surgeons in performing distal locking of long bone intramedullary nails. The system consists of a bone-mounted miniature robot fitted with a drill guide that provides rigid mechanical guidance for hand-held drilling of the distal screws' pilot holes. The robot is automatically positioned so that the drill guide and nail distal locking axes coincide, using a single fluoroscopic X-ray image. Since the robot is rigidly attached to the intramedullary nail or bone, no leg immobilization or real-time tracking is required. We describe the system and protocol and present a method for accurate and robust drill guide and nail hole localization and registration. The in vitro system accuracy experiments for fronto-parallel viewing show a mean angular error of 1.3 degrees (std = 0.4 degrees ) between the computed drill guide axes and the actual locking holes axes, and a mean 3.0 mm error (std = 1.1 mm) in the entry and exit drill point, which is adequate for successfully locking the nail.

Algorithms↗

Precision targeting of liver lesions using a novel electromagnetic navigation device in physiologic phantom and swine.

Radiofrequency ablation of primary and metastatic liver tumors is becoming a potential alternative to surgical resection. We propose a novel system that uses real-time electromagnetic position sensing of the needle tip to help with precision guidance into a liver tumor. The purpose of this study was to evaluate this technology in phantom and animal models. Using an electromagnetic navigation device, instrumented 18 g needles were advanced into radioopaque tumor targets in a respiratory liver phantom. The phantom featured a moving liver target that simulated cranio-caudal liver motion due to respiration. Skin-to-target path planning and real-time needle guidance were provided by a custom-designed software interface based on pre-operative 1 mm CT data slices. Needle probes were advanced using only the electromagnetic navigation device and software display. No conventional real-time imaging was used to assist in advancing the needle to the target. Two experienced operators (interventional radiologists) and two inexperienced ones (residents) used the system. The same protocol was then also used in two anesthetized 45 kg Yorkshire swine where radioopaque agar nodules were injected into the liver to serve as targets. A total of 76 tumor targeting attempts were performed in the liver phantom, and 32 attempts were done in the swine. The average time for path planning was 30 s in the phantom, and 63 s in the swine. The median time for the actual needle puncture to reach the desired target was 33 s in the phantom, and 42 s in the swine. The average registration error between the CT coordinate system and electromagnetic coordinate system was 1.4 mm (SD 0.3 mm) in the phantom, and 1.9 mm (SD 0.4 mm) in the swine. The median distance from the final needle tip position to the center of the tumor was 6.4 mm (SD 3.3 mm, n=76) in the phantom, and 8.3 mm (SD 3.7 mm, n=32) in the swine. There was no statistical difference in the planning time, procedure time, or accuracy of needle placement between experienced and inexperienced operators. The novel electromagnetic navigation system allows probe delivery into hepatic tumors of a physiologic phantom and live anesthetized swine. The system allows less experienced operators to perform equally well as experienced radiologists in terms of procedure time and accuracy of needle probe delivery.

Animals↗

Long bone panoramas from fluoroscopic X-ray images.

This paper presents a new method for creating a single panoramic image of a long bone from several individual fluoroscopic X-ray images. Panoramic images are useful preoperatively for diagnosis, and intraoperatively for long bone fragment alignment, for making anatomical measurements, and for documenting surgical outcomes. Our method composes individual overlapping images into an undistorted panoramic view that is the equivalent of a single X-ray image with a wide field of view. The correlations between the images are established from the graduations of a radiolucent ruler imaged alongside the long bone. Unlike existing methods, ours uses readily available hardware, requires a simple image acquisition protocol with minimal user input, and works with existing fluoroscopic C-arm units without modifications. It is robust and accurate, producing panoramas whose quality and spatial resolution is comparable to that of the individual images. The method has been successfully tested on in vitro and clinical cases.

Algorithms↗

Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT.

We present a gradient-based method for rigid registration of a patient preoperative computed tomography (CT) to its intraoperative situation with a few fluoroscopic X-ray images obtained with a tracked C-arm. The method is noninvasive, anatomy-based, requires simple user interaction, and includes validation. It is generic and easily customizable for a variety of routine clinical uses in orthopaedic surgery. Gradient-based registration consists of three steps: 1) initial pose estimation; 2) coarse geometry-based registration on bone contours, and; 3) fine gradient projection registration (GPR) on edge pixels. It optimizes speed, accuracy, and robustness. Its novelty resides in using volume gradients to eliminate outliers and foreign objects in the fluoroscopic X-ray images, in speeding up computation, and in achieving higher accuracy. It overcomes the drawbacks of intensity-based methods, which are slow and have a limited convergence range, and of geometry-based methods, which depend on the image segmentation quality. Our simulated, in vitro, and cadaver experiments on a human pelvis CT, dry vertebra, dry femur, fresh lamb hip, and human pelvis under realistic conditions show a mean 0.5-1.7 mm (0.5-2.6 mm maximum) target registration accuracy.

Algorithms↗

Comparative in vitro study of contact- and image-based rigid registration for computer-aided surgery.

We present an in vitro study of rigid registration methods for computer-aided surgery. The goals of the study were to obtain accuracy measures empirically under optimal laboratory conditions, and to identify the weak links in the registration chain. Specifically, we investigated two common registration methods (contact-based registration and image-based landmark registration) and established a framework for comparing the accuracy of both methods. The phantoms, protocols, and algorithms for tool tip calibration, contact-based registration with an optical tracker, fluoroscopic X-ray camera calibration, and fluoroscopic X-ray image-based landmark registration are described. Average accuracies of 0.5 mm (1.5 mm maximum) and 2.75 mm (3.4 mm maximum) were found for contact-based and image-based landmark registration, respectively. Based on these findings, the camera calibration was identified as being the main source of error in image-based landmark registration. Protocol improvements and algorithmic refinements to improve the accuracy of image-based landmark registration are proposed.

Algorithms↗