PubMed Health⌕ Search

Biomedical subjects

Zoltán Takáts

Publications and source records attributed to Zoltán Takáts.

At least 19 recordsLinked to original sources

Optimization of MALDI-TOF MS for strain level differentiation of Arthrobacter isolates.

Matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been shown to be a rapid and sensitive method for characterization of bacteria, but it has not yet become a routine microbiological procedure. Currently there are no standardized protocols that would allow development of large libraries of reproducible protein profiles from a broad range of microorganisms to use for identification purposes. Important variables that may affect spectrum quality are MALDI matrices, solvents, cell growth condition, and culture age. In the present study our aim was to: (1) to determine optimal sample preparation and MALDI conditions for discrimination at the strain level; (2) to determine if changes in growth cycle correlated with MALDI spectrum changes; and (3) to compare level of isolate discrimination based on their MALDI spectra versus their 16S rRNA gene sequence. Using 16 strains of the Gram positive bacterium Arthrobacter, optimal spectra were obtained using two-layer sample application of intact cells grown on solid surface overlaid with a matrix consisting of sinapinic acid (SA) or alpha-cyano-hydroxy-cinnaminic acid (CHCA) in 50:50 acetonitrile:water solvent with 2% trifluoroacetic acid. Spectrum changes paralleled the coccus-rod-coccus growth cycle indicative of Arthrobacter. Strain differences based on their MALDI profiles (using Pearson coefficient and UPGMA) corresponded with their 16S rRNA gene phylogeny but it had greater discrimination.

Arthrobacter↗

Desorption electrospray ionization mass spectrometry for high-throughput analysis of pharmaceutical samples in the ambient environment.

Desorption electrospray ionization (DESI) allows mass spectrometry to be used for on-line high-throughput monitoring of pharmaceutical samples in the ambient environment, without prior sample preparation. Positive and negative ion DESI are used to characterize the active ingredients in pharmaceutical samples formulated as tablets, ointments, and liquids. Compounds of a wide variety of chemical types are detected in these complex matrices. The effects on analytical performance of operating parameters, including the electrospray high voltage, heated capillary temperature, solvent infusion rate, and solvent composition, are evaluated and optimized. In addition to experiments in which a simple solvent is sprayed onto the solid analyte samples, reactive desorption is performed by adding reagents to the solvent spray to generate particularly stable or characteristic ions with the analytes of interest. A variable-speed moving belt was built for high-throughput sampling and used to provide rapid qualitative and semiquantitative information on drug constituents in tablets. Sampling rates as high as 3 samples/s are achieved in the ambient environment. Relative standard deviations of the relative ion abundances for major components in the mass spectra are in the range of 2-8%. Impurities and components present at levels as low as approximately 0.1% are identified and carryover effects are minimized in high-throughput on-line analysis of pharmaceutical samples.

Drug Combinations↗

Desorption electrospray ionization of explosives on surfaces: sensitivity and selectivity enhancement by reactive desorption electrospray ionization.

Desorption electrospray ionization (DESI), an ambient mass spectrometry technique, is used for trace detection of the explosives trinitrohexahydro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), 2,4,6-trinitrotoluene (TNT), Pentaerythritol tetranitrate (PETN), and their plastic compositions (Composition C-4, Semtex-H, Detasheet) directly from a wide variety of surfaces (metal, plastic, paper, polymer) without sample preparation or pretreatment. Analysis of the explosives is performed under ambient conditions from virtually any surface in very short times (<5 s) including confirmatory tandem mass spectrometry (MS/MS) experiments, while retaining the sensitivity and specificity that mass spectrometry offers. Increased selectivity is obtained both by MS/MS and by performing additional experiments in which additives are included in the spray solvent. These reactive DESI experiments (reactions accompanying desorption) produce such ions as the chloride and trifluoroacetate adducts of RDX and HMX or the Meisenheimer complex of TNT. Desorption atmospheric pressure chemical ionization, a variant of DESI that uses gas-phase ions generated by atmospheric pressure corona discharges of toluene or other organic compounds, provides evidence for a heterogeneous-phase (gaseous ion/absorbed analyte) charge-transfer mechanism of DESI ionization in the case of explosives. Plastic explosives on surfaces were analyzed directly as fingerprints, without sample preparation, to test DESI as a possible method for in situ detection of explosives-contaminated surfaces. DESI also allowed detection of explosives in complex matrixes, including lubricants, household cleaners, vinegar, and diesel fuel. Absolute limits of detection for the neat explosives were subnanogram in all cases and subpicogram in the case of TNT. The DESI response was linear over 3 orders of magnitude for TNT. Quantification of RDX on paper gave a precision (RSD) of 2.3%. Pure water could be used as the spray solution for DESI, and it showed ionization efficiencies for RDX in the negative ion mode similar to that given by methanol/water. DESI represents a simple and rapid way to detect explosives in situ with high sensitivity and specificity and is especially useful when they are present in complex mixtures or in trace amounts on ordinary environmental surfaces.

Journal Article↗

Rapid in situ detection of alkaloids in plant tissue under ambient conditions using desorption electrospray ionization.

Desorption electrospray ionization (DESI) mass spectrometry is applied to the in situ detection of alkaloids in the tissue of poison hemlock (Conium maculatum), jimsonweed (Datura stramonium) and deadly nightshade (Atropa belladonna). The experiment is carried out by electrospraying micro-droplets of solvent onto native or freshly-cut plant tissue surfaces. No sample preparation is required and the mass spectra are recorded under ambient conditions, in times of a few seconds. The impact of the sprayed droplets on the surface produces gaseous ions from organic compounds originally present in the plant tissue. The effects of operating parameters, including the electrospray high voltage, heated capillary temperature, the solvent infusion rate and the carrier gas pressure on analytical performance are evaluated and optimized. Different types of plant material are analyzed including seeds, stems, leaves, roots and flowers. All the previously reported alkaloids have been detected in C. maculatum, while fifteen out of nineteen known alkaloids for D. stramonium and the principal alkaloids of A. belladonna were also identified. All identifications were confirmed by tandem mass spectrometry. Results obtained show similar mass spectra, number of alkaloids, and signal intensities to those obtained when extraction and separation processes are performed prior to mass spectrometric analysis. Evidence is provided that DESI ionization occurs by both a gas-phase ionization process and by a droplet pick-up mechanism. Quantitative precision of DESI is compared with conventional electrospray ionization mass spectrometry (after sample workup) and the RSD values for the same set of 25 dicotyledonous C. maculatum seeds (one half of each seed analyzed by ESI and the other by DESI) are 9.8% and 5.2%, respectively.

Alkaloids↗

Degradation of atrazine in a laboratory scale model system with Danube river sediment.

A laboratory-scale model system of Danube river gravel bed was constructed. Evaluation of water chemical parameters and composition of bacterial communities confirmed the liability of the model. Degradation of atrazine, a frequent micropollutant of Danube water was examined in the model system. In case of an acute atrazine load, short-term retention of the compound was observed, accumulation and degradation were not significant. Long-term continuous dose of atrazine led to enhanced degradation of the pollutant. Principal metabolite was hydroxyatrazine. Atrazine utilizing strains isolated from the sediment belong to various, predominantly Gram positive genera and have diverse atrazine metabolism. Dominant metabolic reactions are dechlorination, dealkylation and deamination, with the sequential products ammeline and ammelide. The strain Delftia acidovorans D24 mineralizes atrazine as a sole source of carbon and nitrogen.

Atrazine↗

High-throughput mass spectrometer using atmospheric pressure ionization and a cylindrical ion trap array.

The analytical performance of an atmospheric pressure sampling, multiple-channel, high-throughput mass spectrometer was investigated using samples of a variety of types. The instrument, based on an array of cylindrical ion traps, was built with four independent channels and here is operated using two fully multiplexed channels (sources, ion optics, ion traps, detectors) capable of analyzing different samples simultaneously. Both channels of the instrument were incorporated within the same vacuum system and operated using a common set of control electronics. A multichannel electrospray ionization source was assembled and used to introduce samples including solutions of organic compounds, peptides, and proteins simultaneously into the instrument in a high-throughput fashion. Cross-talk between the channels of the instrument occurred in the detection system and could be minimized to 1-2% using shielding between detector channels. In this initial implementation of the instrumentation, an upper mass/charge limit of approximately 1300 Th was observed (+13 charge state of myoglobin) and unit mass/charge resolution was achieved to approximately 800 Th. The rather limited dynamic range (2-3 orders of magnitude for low-concentration analytes) is due to cross-talk contributions from more concentrated species introduced into a different channel. Analysis of mixtures of alkylamines and peptides is demonstrated, but analysis of mixtures with a wide spread in mass/charge ratios was not possible due to mass discrimination in the ion optics. Further refinement of the vacuum system and ion optics will allow the addition of more channels of parallel mass analysis and facilitate applications in fields such as proteomics and metabolomics.

Amines↗

Ambient mass spectrometry using desorption electrospray ionization (DESI): instrumentation, mechanisms and applications in forensics, chemistry, and biology.

Analytical characteristics of DESI are summarized. Examples of applications to small and large molecules, to in situ analysis, and to high-throughput analyses are presented. Evidence is provided for both a heterogeneous charge-transfer mechanism and a droplet pick-up mechanism of ionization. The speed, lack of the need for sample preparation, selectivity, and sensitivity of DESI are all demonstrated and discussed. Instrumentation is also discussed. Forensic applications as well as emerging areas of application including tissue imaging are given emphasis.

Animals↗

Preparative linear ion trap mass spectrometer for separation and collection of purified proteins and peptides in arrays using ion soft landing.

A preparative mass spectrometer for microarray fabrication is reported. The instrument includes an atmospheric pressure ionization source, a linear ion trap mass analyzer, an ion collection surface positioning system, and a surface loading chamber with independent vacuum pumping. It was designed for the production of protein arrays using the ion soft-landing technique to collect ions on a surface after separation by mass/charge ratio. Small microarrays have been prepared by isolating and soft landing individual protein or peptide ions after electrospray ionization of mixtures. The composition and purity of the separated materials has been confirmed using independent external mass spectrometric analysis of rinse solutions of the collected spots, either by the new method of electrosonic spray ionization MS or by nanospray ionization MS. The ability to retain bioactivity in the mass-selected and collected biomolecules has been demonstrated in particular cases. The reported instrument has also been characterized as an analytical mass spectrometer.

Amino Acid Sequence↗

Mass spectrometry sampling under ambient conditions with desorption electrospray ionization.

A new method of desorption ionization is described and applied to the ionization of various compounds, including peptides and proteins present on metal, polymer, and mineral surfaces. Desorption electrospray ionization (DESI) is carried out by directing electrosprayed charged droplets and ions of solvent onto the surface to be analyzed. The impact of the charged particles on the surface produces gaseous ions of material originally present on the surface. The resulting mass spectra are similar to normal ESI mass spectra in that they show mainly singly or multiply charged molecular ions of the analytes. The DESI phenomenon was observed both in the case of conductive and insulator surfaces and for compounds ranging from nonpolar small molecules such as lycopene, the alkaloid coniceine, and small drugs, through polar compounds such as peptides and proteins. Changes in the solution that is sprayed can be used to selectively ionize particular compounds, including those in biological matrices. In vivo analysis is demonstrated.

Journal Article↗

Electrosonic spray ionization. A gentle technique for generating folded proteins and protein complexes in the gas phase and for studying ion-molecule reactions at atmospheric pressure.

Electrosonic spray ionization (ESSI), a variant on electrospray ionization (ESI), employs a traditional micro ESI source with supersonic nebulizing gas. The high linear velocity of the nebulizing gas provides efficient pneumatic spraying of the charged liquid sample. The variable electrostatic potential can be tuned to allow efficient and gentle ionization. This ionization method is successfully applied to aqueous solutions of various proteins at neutral pH, and its performance is compared to that of the nanospray and micro ESI techniques. Evidence for efficient desolvation during ESSI is provided by the fact that the peak widths for various multiply charged protein ions are an order of magnitude narrower than those for nanospray. Narrow charge-state distributions compared to other ESI techniques are observed also; for most of the proteins studied, more than 90% of the protein ions can be accumulated in one charge state using ESSI when optimizing conditions. The fact that the abundant charge state is normally as low or lower than that recorded by ESI or nanospray indicates that folded protein ions are generated. The sensitivity of the ionization technique to high salt concentrations is comparable to that of nanospray, but ESSI is considerably less sensitive to high concentrations of organic additives such as glycerol or 2-amino-2-(hydroxymethyl)-1,3-propanediol (Tris base). Noncovalent complexes are observed in the case of myoglobin, protein kinase A/ATP complex, and other proteins. The extent of dissociation of protein ions in ESSI is comparable to or even smaller than that in the case of nanospray, emphasizing the gentle nature of the method. The unique features of ESSI are ascribed to very efficient spraying and the low internal energy supplied to the ions. Evidence is provided that the method is capable of generating fully desolvated protein ions at atmospheric pressure. This allows the technique to be used for the study of ion-molecule reactions at atmospheric pressure and examples of this are shown.

Atmospheric Pressure↗

Thermal formation of serine octamer ions.

Vigorous evaporation of aqueous serine solutions yields abundant protonated serine octamer ions. So does pyrolysis of L-serine crystals in a corona discharge.

Journal Article↗

Atmospheric pressure chemical ionization mass spectrometry of aldehydes in biological matrices.

Application of high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) for detection of aldehydes in biological samples such as blood, yoghurt, and milk, is reported. Sample preparation is easy, and the presented method is both sensitive and selective. It is based on the widely used dinitrophenylhydrazine derivatization, followed by extraction with n-hexane and a simple reversed-phase HPLC separation. Detection is performed by atmospheric pressure chemical ionization (APCI) in negative ion mode, with detection limits in the low picogram range. Using MS/MS, acetone and propionaldehyde can clearly be distinguished, facilitating propionaldehyde quantitation even in the presence of high acetone levels. Quantitation by direct MS/MS is also feasible, well suited for high-throughput applications, although not as accurate as using HPLC/MS/MS.

Aldehydes↗

Ion soft-landing into liquids: Protein identification, separation, and purification with retention of biological activity.

Protein ions, after mass spectrometric separation, can be soft-landed into liquid surfaces with preservation of their native structures. Retention of biological activity is strongly favored in glycerol-based surfaces but not in self-assembled monolayer solid surfaces. Soft-landing efficiency for multiply-charged hexokinase ions was found to be some four times higher for a glycerol/fructose liquid surface than for a fluorinated self-assembled monolayer surface. Soft-landing into liquid surfaces is also shown to allow (1) protein purification, (2) on-surface identification of the soft-landed material using MALDI, and (3) protein identification by in-surface tryptic digestion. Pure lysozyme was successfully isolated from different mixtures including an oxidized, partially decomposed batch of the protein and a partial tryptic digest. Liquid glycerol/carbohydrate mixtures could be used directly to record MALDI spectra on the soft-landed compounds provided they were fortified in advance with traditional MALDI matrices such as p-nitroaniline and alpha-cyano-4-hydroxycinnamic acid. Various proteins were soft-landed and detected on-target using these types of liquid surface. Soft-landing of multiply-charged lysozyme ions onto fluorinated self-assembled monolayer surfaces was found to occur with a limited amount of neutralization, and trapped multiply-charged ions could be desorbed from the surface by laser desorption. Initial data is shown for a new approach to protein identification that combines top-down and bottom-up approaches by utilizing protein ion soft-landing from a protein mixture, followed by tryptic digestion of the landed material and detection of characteristic tryptic fragments by MALDI.

Amino Acid Sequence↗

Preparing protein microarrays by soft-landing of mass-selected ions.

Intact, multiply protonated proteins of particular mass and charge were selected from ionized protein mixtures and gently landed at different positions on a surface to form a microarray. An array of cytochrome c, lysozyme, insulin, and apomyoglobin was generated, and the deposited proteins showed electrospray ionization mass spectra that matched those of the authentic compounds. Deposited lysozyme and trypsin retained their biological activity. Multiply charged ions of protein kinase A catalytic subunit and hexokinase were also soft-landed into glycerol-based liquid surfaces. These soft-landed kinases phosphorylated LRRASLG oligopeptide and D-fructose, respectively.

Apoproteins↗

Formation of solvated ions in the atmospheric interface of an electrospray ionization triple-quadrupole mass spectrometer.

A simple method capable of generating and investigating various solvent clusters and solvated ions was developed. The technique opens a door to studying these complexes on commercially available instruments. Formation of the desired solvated ion in the gas phase was achieved by introducing the appropriate volatile solvent vapour into the curtain gas stream. Capabilities of the technique are illustrated by generating alkali, alkaline earth and transition metal cations solvated by various volatile compounds such as water, methanol and acetonitrile. Depending on the ligands and on the experimental conditions, clusters of 2-100 molecules may be observed. Isotope labelling suggests that these are formed by a re-solvation process in the curtain gas region.

Journal Article↗