PubMed Health⌕ Search

Biomedical subjects

Zoltan Takats

Publications and source records attributed to Zoltan Takats.

6 recordsLinked to original sources

Detection Technologies. Ambient mass spectrometry.

A recent innovation in mass spectrometry is the ability to record mass spectra on ordinary samples, in their native environment, without sample preparation or preseparation by creating ions outside the instrument. In desorption electrospray ionization (DESI), the principal method described here, electrically charged droplets are directed at the ambient object of interest; they release ions from the surface, which are then vacuumed through the air into a conventional mass spectrometer. Extremely rapid analysis is coupled with high sensitivity and high chemical specificity. These characteristics are advantageously applied to high-throughput metabolomics, explosives detection, natural products discovery, and biological tissue imaging, among other applications. Future possible uses of DESI for in vivo clinical analysis and its adaptation to portable mass spectrometers are described.

Animals↗

Coupling desorption electrospray ionization with ion mobility/mass spectrometry for analysis of protein structure: evidence for desorption of folded and denatured States.

A desorption electrospray ionization (DESI) source has been coupled to an ion mobility time-of-flight mass spectrometer for the analysis of proteins. Analysis of solid-phase horse heart cytochrome c and chicken egg white lysozyme proteins with different DESI solvents and conditions shows similar mass spectra and charge state distributions to those formed when using electrospray to analyze these proteins in solution. The ion mobility data show evidence for compact ion structures [when the surface is exposed to a spray that favors retention of "nativelike" structures (50:50 water:methanol)] or elongated structures [when the surface is exposed to a spray that favors "denatured" structures (49:49:2 water:methanol:acetic acid)]. The results suggest that the DESI experiment is somewhat gentler than ESI and under appropriate conditions, it is possible to preserve structural information throughout the DESI process. Mechanisms that are consistent with these results are discussed.

Absorption↗

Chiral enrichment of serine via formation, dissociation, and soft-landing of octameric cluster ions.

Chiral enrichment of serine is achieved in experiments that involve formation of serine octamers starting from non-racemic serine solutions. Serine octamers were generated by means of electrospray and sonic spray ionization of aqueous solutions of d(3)-L-serine (108 Da) and D-serine (105 Da) having different molar ratios of enantiomers. A cyclic process involving the formation of chirally-enriched octameric cluster ions and their dissociation, viz. Ser(1) --> Ser(8) --> Ser(1), allows serine monomers to be regenerated with increased enantiomeric excess as shown in two types of experiments: (1) Chiral enrichment in serine was observed in MS/MS/MS experiments in a quadrupole ion trap in which the entire distribution of serine octamers formed from non-racemic solutions was isolated, collisionally activated, and fragmented. Monomeric serine was regenerated with increased enantiomeric excess upon dissociation of octamers when compared with the enantiomeric composition of the original solution. (2) Chiral enrichment was observed in the products of soft-landing of mass-selected protonated serine octamers. These ions were generated by means of electrospray or sonic spray ionization, mass selected, and collected on a gold surface using ion soft-landing. Chiral enrichment of the soft-landed serine was established by redissolving the recovered material and comparing the intensities of protonated molecular ions of d(3)-L-serine and D-serine after APCI-MS analysis. Both of these experiments showed comparable results, suggesting that formation of serine octamers depends only on the enantiomeric composition of the serine solution and that the magnitude of the chiral preference is intrinsic to octamers formed from solutions of given chiral composition.

Ions↗

Atmospheric pressure gas-phase H/D exchange of serine octamers.

The recently discovered homochiral serine octamer has been a focus of interest because of its possible implications for the origin of homochirality in living systems. Electrospray ionization (ESI) and sonic spray ionization (SSI) tandem mass spectrometry have been used to generate this unusually stable magic number cluster. Several structures have been suggested for the serine octamer, based on tandem mass spectrometry, ion mobility measurements, and quantum mechanical calculations. We now report experimental hydrogen/deuterium (H/D) exchange data, which demonstrate the existence of two different structures for the serine octamer. These forms undergo exchange at significantly different rates. One form may correspond to solution-phase assembled clusters and the other to octamers formed during the ionization process. Experiments done at higher resolution confirm that the experimental observations made here apply to the serine octamer without interference from metaclusters, namely, higher order clusters (Ser(16) + 2H)(+2), etc., the (12)C isotopes of which have mass-to-charge ratios identical to the protonated octamers. H/D exchange of racemic serine shows predominantly the extensively exchanged ion population, as well as providing evidence that racemic serine generates abundant metaclusters. The evidence presented here shows that one type of serine octamer is responsible for the strong chiral effects associated with the formation of these magic number clusters. These slowly exchanging more fragile clusters are the octamers that might have played a role in homochirogenesis.

Atmospheric Pressure↗

Amino acid clusters formed by sonic spray ionization.

A novel ion source based on the principle of sonic spray ionization has been built and used to optimize mass spectrometric conditions for generating amino acid clusters. The ion source employs a simple pneumatic spray operated at extremely high nebulizing gas flow rates. Several factors that affect the performance of the cluster source are identified, and information from these observations provides insights into the mechanisms of gas phase ion formation. Serine is used as a model system in optimizing instrumental and sample parameters to maximize cluster ion formation. The sonic spray results for this oligomer compare favorably with electrospray data, showing an order of magnitude better signal intensity and excellent signal-to-noise ratios. The performance of the system for the protonated serine octamer includes a limit of detection of 10 nM and a linear dynamic range of 4 orders of magnitude. Ion formation was observed to go into saturation above 1 mM. This result and data on pH, electrolyte concentration, and solvent composition are interpreted as supporting a charge residue model of sonic spray ionization. Other amino acids can be substituted for serine in the octamer, with a strong chiral preference in favor of homochiral cluster formation in the cases of threonine and cysteine. These amino acids show a preference for substitution of more than two serine molecules. Phenylalanine, asparagine, tryptophan, and tyrosine also substitute into the serine octamer; however, the process yields only two incorporations and only small chiral effects.

Amino Acids↗