Potentiometric biosensing of proteins with ultrasensitive ion-selective microelectrodes and nanoparticle labels.

We report here for the first time on the use of potentiometry for ultrasensitive nanoparticle-based detection of protein interactions. A silver ion-selective microelectrode is used to detect silver ions oxidatively released from silver enlarged gold nanoparticle labels in a sandwich immunoassay. Since potentiometry is expected to largely maintain its analytical characteristics upon reducing the sample volume, it is anticipated that this approach may form the basis for bioassays with attractive detection limits.

Biosensing Techniques↗

Layer-by-layer hydroxymethyl ferrocene modified sensor for one-step flow/stop-flow injection amperometric immunoassay of alpha-fetoprotein.

A rapid one-step flow/stop-flow injection amperometric immunoassay for alpha-fetoprotein (AFP) using a novel home-produced electrochemical sensor was proposed. The sensor was prepared using layer-by-layer adsorption of positively charged poly(allylamine) (PAA) and negatively charged hydroxymethyl ferrocene on a screen-printed electrode (SPE). The electrochemistry of the immobilized ferrocene moieties showed a surface-controlled electrode process. Based on an electrochemical enzyme-linked immunoassay with the immobilized ferrocene moieties as an electron transfer mediator between the electrode and the horseradish peroxidase (HRP)-labeled anti-AFP antibody, a calibration curve with two linear ranges from 5 to 20 and 20 to 150 ng ml-1 and a detection limit of 2 ng ml-1 for AFP determination was obtained under the optimized conditions of 0.891 ml min-1 flow rate, 20 microl injection volume and +25 mV applied potential. The sensor showed good repeatability and reproducibility and retained more than 95% of its original signal after 15 days of storage. The proposed method eliminated the need for washing and addition of any substrate or mediator. The complete assay could be handled in less than 25 min with a one-step injection of a 40 microl sample solution. The proposed method would be valuable for the diagnosis and monitoring of carcinoma and its metastasis.

Biosensing Techniques↗

Nanoparticle-based sensing of glycan-lectin interactions.

Here we present the first report on nanoparticle-based biosensing of glycan markers of diseases. The protocol relies on the competition between a nanocrystal (CdS)-tagged sugar and the target sugar for the binding sites of surface-confined lectin and monitoring the extent of competition through highly sensitive electrochemical detection of the captured nanocrystal. This development is expected to allow decentralized detection of carbohydrate moieties and lectin-carbohydrate interactions to be performed more rapidly, sensitively, inexpensively, and reliably.

Lectins↗

Sensitive and rapid electrochemical bioassay of glycosidase activity.

Here we present a highly sensitive, rapid and simple electrochemical assay for glycosidases based on treatment of the glycosidase with the appropriate p-nitrophenyl glycoside and anodic detection of released p-nitrophenol. The attractive characteristics of the new bioassay should facilitate advanced glycomic research and routine clinical diagnostics since glycosidases are associated with various diseases.

Bacteria↗

A disposable electrochemical immunosensor for flow injection immunoassay of carcinoembryonic antigen.

A new simple immunoassay method for carcinoembryonic antigen (CEA) detection using a disposable immunosensor coupled with a flow injection system was developed. The immunosensor was prepared by coating CEA/colloid Au/chitosan membrane at a screen-printed carbon electrode (SPCE). Using a competitive immunoassay format, the immunosensor inserted in the flow system with an injection of sample and horseradish peroxidase (HRP)-labeled CEA antibody was used to trap the labeled antibody at room temperature for 35 min. The current response obtained from the labeled HRP to thionine-H(2)O(2) system decreased proportionally to the CEA concentration in the range of 0.50-25 ng/ml with a correlation coefficient of 0.9981 and a detection limit of 0.22 ng/ml (S/N=3). The immunoassay system could automatically control the incubation, washing and current measurement steps with good stability and acceptable accuracy. Thus, the proposed method proved its potential use in clinical immunoassay of CEA.

Biosensing Techniques↗

Electrochemical sensor for immunoassay of carcinoembryonic antigen based on thionine monolayer modified gold electrode.

A sensor based on thionine monolayer modified gold electrode for determination of carcinoembryonic antigen (CEA) in human serum is proposed. The sensor is prepared by covalently binding thionine to a cysteamine self-assembled monolayer with p-phthaloyl chloride as a linkage, which gives a surface coverage of 8.97+/-3.28 x 10(-12)mol/cm(2) for thionine. The electrochemistry of the immobilized thionine displays a surface-controlled electrode process with an average electron transfer rate constant of 1.47+/-0.84 s(-1). Based on an electrochemical enzyme-linked immunoassay by using the immobilized thionine as an electron transfer mediator between the electrode and the horseradish peroxidase (HRP) labeled anti-CEA antibody, a calibration curve with two linear ranges from 0.6 to 17 and 17 to 200 ng/mL and a detection limit of 0.2 ng/mL for CEA determination is obtained in pH 4.2 PBS containing 2.0 mmol/L H(2)O(2) and 0.5 mol/L NaCl. The sensor shows a good accuracy. The precision and reproducibility are acceptable with the intra-assay CV of 4.9% and 5.9% at 10 and 100 ng/mL CEA concentrations, respectively, and the inter-assays CV of 7.8% at 100 ng/mL CEA. The response of thionine modified electrode shows only 1.6% decrease after 100 replicate measurements and the storage stability is acceptable in a pH 7.0 PBS at 4 degrees C for 1 week. The method avoids the addition of electron transfer mediator to the solution, thus is much simpler. The proposed method would be valuable for the diagnosis and monitoring of carcinoma and its metastasis.

Antibodies↗

Reagentless amperometric immunosensor for human chorionic gonadotrophin based on direct electrochemistry of horseradish peroxidase.

A novel amperometric immunosensor for determination of human serum chorionic gonadotrophin (HCG) was constructed by immobilization of HCG with titania sol-gel on a glassy carbon electrode and the direct electrochemistry of horseradish peroxidase (HRP) labeled to HCG antibody (HRP-anti-HCG). The morphologies of the HCG membrane were characterized to be chemically clean, porous and homogeneous. HRP-anti-HCG was functionally conjugated with the immobilized HCG after incubation in phosphate buffer (PBS) containing HRP-anti-HCG. A direct electron transfer of HRP with a rate constant of 1.35+/-0.40 s(-1) was observed at the HRP-anti-HCG-HCG/titania sol-gel membrane modified electrode in 0.1 M PBS pH 7.0. With a competitive mechanism the differential pulse voltammetric peak current of the immobilized HRP decreased linearly with an increasing HCG concentration from 2.5 to 12.5 mIU/ml in the incubation solution. The HCG immunosensor showed a detection limit of 1.4 mIU/ml, a good accuracy and acceptable precision and reproducibility with an intra-assay CV of 4.7% at 5.0 mIU/ml and an inter-assay precision of 8.1% obtained at 10 mIU/ml. The biosensor displayed a good stability in a storage period of 30 days.

Biosensing Techniques↗

A disposable amperometric immunosensor for alpha-1-fetoprotein based on enzyme-labeled antibody/chitosan-membrane-modified screen-printed carbon electrode.

A screen-printed three-electrode system is fabricated to prepare a novel disposable screen-printed immunosensor for rapid determination of alpha-1-fetoprotein (AFP) in human serum. The immunosensor is prepared by entrapping horseradish peroxidase (HRP)-labeled AFP antibody in chitosan membrane to modify the screen-printed carbon electrode. The membrane is characterized with scanning electron microscope and electrochemical methods. After the immunosensor is incubated with AFP at 30 degrees C for 35 min, the access of the active center of HRP catalyzing the oxidation reaction of thionine by H(2)O(2) is partly inhibited. In presence of 1.2 mM thionine and 6 mM H(2)O(2), the electrocatalytic current decreases linearly in two concentration ranges of AFP from 0 to 20 and from 20 to 150 ng/mL with a detection limit of 0.74 ng/mL. The immunosensor shows an acceptable accuracy compared with those obtained from immunoradiometric assays. The interassay coefficients of variation are 6.6 and 4.2% at 10 and 100 ng/mL, respectively. The storage stability is acceptable in pH 7.0 phosphate buffer solution at 4 degrees C for more than 10 days. The proposed method can detect the AFP through one-step immunoassay and would be valuable for clinical immunoassay.

Antibodies↗

Novel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen.

A novel immunosensor for rapid separation-free determination of carcinoembryonic antigen (CEA) in human serum is proposed. The immunosensor is prepared by co-immobilizing thionine and horseradish peroxidase (HRP)-labeled CEA antibody on a glassy carbon electrode (GCE) through covalently binding them to GCE with a glutaraldehyde (GA) linkage. The electrochemical behavior of the immobilized thionine displays a surface-controlled electrode process with an average electron transfer rate constant of 4.74+/-2.99 s(-1). It can be used as an electron transfer mediator for enzymatic activity detection of the HRP-labeled antibody to CEA. After the immunosensor is incubated with CEA solution at 23 degrees C for 40 min, the access of activity center of the HRP to thionine is partly inhibited, which leads to a linear decrease in the catalytic efficiency of the HRP to the oxidation of immobilized thionine by H(2)O(2) at -300 mV over two CEA concentration ranges from 0.5 to 3.0 and 3.0 to 167 ng/ml. Under optimal conditions, the detection limit for the CEA immunoassay is 0.1 ng/ml at three times background noise. The immunosensor shows good accuracy and acceptable storage stability, precision and reproducibility with intra-assay CVs of 6.1% and 5.8% at 2.5 and 50 ng/ml CEA, respectively, and an inter-assay CV of 6.3% at 50 ng/ml. This method is economical and shortens the analytical time, making it potentially attractive for clinical immunoassays.

Antibodies↗

Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125.

A novel strategy for immunoassay and the preparation of reagentless immunosensors was proposed. This strategy was based on the immobilization of antigen and the direct electrochemistry of horseradish peroxidase (HRP) that was labeled to an antibody. A reagentless immunosensor for carcinoma antigen-125 (CA 125) determination was developed. The immunosensor was prepared by immobilizing CA 125 with titania sol-gel on a glassy carbon electrode by the vapor deposition method. The incubation of the immunosensor in phosphate buffer solution (PBS) including HRP-labeled CA 125 antibody led to the formation of a HRP-modified surface. The immobilized HRP displayed its direct electrochemistry with a rate constant of 3.04 +/- 1.21 s(-1). With a competition mechanism, a differential pulse voltammetric determination method for CA 125 was established by the peak current decrease of the immobilized HRP. The current decrease resulted from the competitive binding of the CA 125 in sample solution and the immobilized CA 125 to the limited amount of HRP-labeled CA 125 antibody. Under optimal conditions, the current decrease was proportional to CA 125 concentration ranging from 2 to 14 units mL(-1) with a detection limit of 1.29 units mL(-1) at a current decrease by 10%. The CA 125 immunosensor showed good accuracy and acceptable precision and fabrication reproducibility with intraassay CVs of 8.7 and 5.5% at 8 and 14 units mL(-1) CA 125 concentrations, respectively, and interassay CV of 19.8% at 8 units mL(-1). The storage stability was acceptable in a pH 7.0 PBS at 4 degrees C for 15 days. The proposed method provided a new promising platform for clinical immunoassay.

Antibodies, Monoclonal↗