Oral-based techniques for the diagnosis of infectious diseases.

Saliva and other types of oral samples can readily be used for noninvasive diagnosis of diseases of the oral cavity and systemic diseases. Following an introduction outlining the types of oral samples and the analytes that can be measured in these samples, a detailed description of a novel oral-based diagnostic system to detect multiple bacterial and/or viral pathogens is presented. A reasonably priced, portable, point-of-care diagnostic system should be available within five years.

Communicable Diseases↗

A disposable microfluidic cassette for DNA amplification and detection.

A pneumatically driven, disposable, microfluidic cassette comprised of a polymerase chain reaction (PCR) thermal cycler, an incubation chamber to label PCR amplicons with up-converting phosphor (UPT) reporter particles, conduits, temperature-activated, normally closed hydrogel valves, and a lateral flow strip, was constructed and tested. The hydrogel valves, which were opened and closed with the aid of electrically controlled thermoelectric units, provided a simple means to seal the PCR reactor and suppress bubble formation. The hydrogel-based flow control was electronically addressable, leakage-free, and biocompatible. To test the device, a solution laden with genomic DNA isolated from B. cereus was introduced into the microfluidic cassette and a specific 305 bp fragment was amplified. The PCR amplicons were labelled with the phosphor (UPT) reporter particles, applied to the lateral flow strip, bound to pre-immobilized ligands, and detected with an IR laser that scanned the lateral flow strip and excited the phosphor (UPT) particles that, in turn, emitted light in the visible spectrum. The UPT particles do not bleach, they provide a permanent record, and they readily facilitate the filtering of background noise. The cassette described herein will be used for rapid testing at the point of care.

Hydrogel, Polyethylene Glycol Dimethacrylate↗

Thermally-actuated, phase change flow control for microfluidic systems.

An easy to implement, thermally-actuated, noninvasive method for flow control in microfluidic devices is described. This technique takes advantage of the phase change of the working liquid itself-the freezing and melting of a portion of a liquid slug-to noninvasively close and open flow passages (referred to as a phase change valve). The valve was designed for use in a miniature diagnostic system for detecting pathogens in oral fluids at the point of care. The paper describes the modeling, construction, and characteristics of the valve. The experimental results favorably agree with theoretical predictions. In addition, the paper demonstrates the use of the phase change valves for flow control, sample metering and distribution into multiple analysis paths, sealing of a polymerase chain reaction (PCR) chamber, and sample introduction into and withdrawal from a closed loop. The phase change valve is electronically addressable, does not require any moving parts, introduces only minimal dead volume, is leakage and contamination free, and is biocompatible.

Microfluidic Analytical Techniques↗

Self-actuated, thermo-responsive hydrogel valves for lab on a chip.

An easy to fabricate, thermally-actuated, self-regulated hydrogel valve for flow control in pneumatically driven, microfluidic systems is described. This microvalve takes advantage of the properties of the hydrogel, poly(N-isopropylacrylamide), as well as the aqueous fluid itself to realize flow control. The valve was designed for use in a diagnostic system fabricated with polycarbonate and aimed at the detection of pathogens in oral fluids at the location of the sample collection. The paper describes the construction and characterization of the hydrogel valves and their application for flow control, sample and reagent metering, sample distribution into multiple analysis paths, and the sealing of a polymerase chain reaction (PCR) reactor to suppress bubble formation. The hydrogel-based flow control is electronically addressable, does not require any moving parts, introduces minimal dead volume, is leakage and contaminant free, and is biocompatible.

Acrylic Resins↗

Thermosiphon-based PCR reactor: experiment and modeling.

A self-actuated, flow-cycling polymerase chain reaction (PCR) reactor that takes advantage of buoyancy forces to continuously circulate reagents in a closed loop through various thermal zones has been constructed, tested, and modeled. The heating required for the PCR is advantageously used to induce fluid motion without the need for a pump. Flow velocities on the order of millimeters per second are readily attainable. In our preliminary prototype, we measured a cross-sectionally averaged velocity of 2.5 mm/s and a cycle time of 104 s. The flow velocity is nearly independent of the loop's length, making the device readily scalable. Successful amplifications of 700- and 305-bp fragments of Bacillus cereus genomic DNA have been demonstrated. Since the device does not require any moving parts, it is particularly suitable for miniature systems.

Bacillus cereus↗