PubMed · 1001526
Puerperal Weck clip sterilization: study I (first study of two consecutive studies).
Abstract
One hundred and four puerperal applications have been performed using the (original) Weck pistol-grip applicator and applying the large Weck clip in the inverted V configuration. Follow-up varied from 37 to 42 months. The corrected failure rate was 8.7%. Mechanical difficulties were encountered with the jaws and metal sleeve of the (original) Weck pistol-grip applicator. Recovered clip configuration and tubal tissue histology are presented. Histologic changes suggest possible reversibility.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
S W Arnold, J C Morrison, S A Fish. 1976. Puerperal Weck clip sterilization: study I (first study of two consecutive studies).. https://doi.org/10.1016/s0015-0282(16)42255-7