[Improved endocardium imaging using modified transthoracic echocardiography with the second harmonic frequency (tissue harmonic imaging)].

Abstract

UNLABELLED: In human tissue sound propagation is not linear resulting in a modification of the ultrasound waves. Therefore the received ultrasound frequencies are not just the transmitted frequencies of the transducer, but contain additional harmonic frequencies. These frequencies were not used by standard echocardiography. Harmonic imaging processes the second harmonic frequency. Distortion of the transmitted beam by shallow surface layers or reverberations between the skin surface and ribs impair image quality in conventional 2-dimensional echocardiography. Since harmonic components develop with propagation distance, the reverberations are almost entirely made up of ultrasound energy at the fundamental frequency. The exclusive processing of the second harmonic frequency provides an impressive improvement in image quality of 2-dimensional echocardiograms. Noise and clutter artifacts are reduced and endocardial borders are enhanced. Commercially available imagers provide tissue harmonic imaging using transmit frequencies from 1.7 to 2.1 MHz and second harmonic frequencies between 3.4 and 4.2 MHz. Several clinical studies have shown that harmonic imaging was superior to standard echocardiography in the assessment of left ventricular (LV) wall motion by LV wall motion analysis. In patients with poor acoustic windows the number of myocardial segments which could be evaluated was significantly higher using harmonic imaging than standard echocardiography. Tissue harmonic imaging particularly improves the delineation of the anterior wall using the 2-chamber view and the lateral wall using the 4-chamber view. CONCLUSION: Harmonic imaging is a clinically relevant improvement of echocardiography. We suggest that this new technology should be the method of choice in the evaluation of LV function.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Becher, K Tiemann. 1998. [Improved endocardium imaging using modified transthoracic echocardiography with the second harmonic frequency (tissue harmonic imaging)].. https://doi.org/10.1007/bf03043753

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗