PubMed Health⌕ Search

PubMed · 10023584

[Improved structure identification with tissue Doppler echocardiography].

Abstract

Tissue Doppler echocardiography (TDE) has been shown to be of particular value in patients with impaired myocardial function. Recently, the technique was successfully employed to localize the ventricular insertion of accessory atrioventricular pathways. The identification of abnormal cardiac structures is coming up now as a new field of clinical interest. The purpose of this study was to differentiate anomalous cardiac and aortic from native structures by physical properties of tissue motion using transesophageal TDE. Characteristic motion patterns of anomalous structures have not been described in detail and tissue Doppler findings have not been associated with clinical features up to now. Forty consecutive patients were included after anomalous cardiac or vascular structures had been detected by conventional transesophageal echocardiography (TEE). A control group consisted of 20 subjects. Rapidity of diagnosis in anomalous structures was divided into 3 categories, and TDE signals were related to particular pathology by a blinded, 2nd observer. Three different motion patterns could be defined: incoherent motion due to free oscillation of an anomalous structure which is independent of the surrounding tissue (Figure 1b); coherent motion with a phase difference meaning that motion depends on the motion of the surrounding tissue but is out of phase (Figure 2); concordant motion showing no difference in direction, velocity, or phase of motion compared with the surrounding tissue. Incoherent motion was present in endocarditic vegetations, 4th degree aortic plaques, Chiari network, valvular prolapse, intracavitary tumors, and freely oscillating thrombi as well as in normal valve leaflets and papillary muscles. Especially if endocarditic vegetations are present its incoherent motion facilitates to recognize these small structures. The colorcode of this motion pattern demarcates the vegetation reliably from the surrounding tissue (Figure 1b). Within 15 seconds vegetations could be detected in 9 (82%) vs 2 (18%) patients employing only conventional imaging. Using conventional echocardiographic approaches detection of vegetations is frequently hindered by their small size and minor echo intensity (Figure 1a). In contrast, size and echo intensity do not affect the tissue Doppler signal. Normal papillary muscles and distal portions of the mitral and tricuspid valves were demonstrated to regularly meet the criterion of incoherent tissue motion in the control group. In part, this was also observed with respect to the aortic and pulmonary valves. In valvular tissue incoherent motion was caused by passive floating, whereas papillary muscles show an active inverse motion for short time intervals. Nevertheless, physiologic incoherent motion did not lead to any false differential diagnosis. The phase difference of coherent motion results from damped oscillation. This phenomenon was visualized by tissue Doppler M-mode in 5 thrombi of the left atrial appendage (LAA) (100%) and in 1 ventricular thrombus (50% of all clots). Concordant motion was shown in 3rd degree aortic plaques and postrheumatic and calcified vegetations. These structures were found to be completely embedded or closely attached, so that their passive motion corresponded to the motion of the surrounding regular tissue. Detection and assessment of anomalous structures are based on their motion patterns which can be synchronous or asynchronous in comparison with the surrounding tissue. Another goal of this investigation was to test if the sensitivity of TEE to spontaneous echo contrast can be improved using TDE. In 21 patients presenting with left atrial dilation (left atrial diameter > 44 mm) due to mitral stenosis (n = 8), mitral regurge (n = 5), arterial hypertension (n = 5) and multiple valvular disease (n = 3) fundamental multiplane TEE and transesophageal TDE were performed with standardized gain setting. The control group consisted of 20 randomized individuals with normal left

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Bartel, S Müller, S Möhlenkamp, C Bruch, J Schaar, R Erbel. 1998. [Improved structure identification with tissue Doppler echocardiography].. https://doi.org/10.1007/bf03043757

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Hydatid cyst involving the aortic arch.

We report a very rare case of primary mediastinal hydatid cyst which invaded the ascending aorta and the aortic arch which initially presented as a cranial mass. Aortic wall is a very unusual site for the hydatid cysts. To the best of our knowledge, this is the first reported case of hydatid cyst located within the aortic arch lumen. Patient underwent ascending aortic and hemiarch replacement under hypothermic circulatory arrest and removal of the cyst. Patient had an uneventful recovery and has been on follow-up. Although the literature data are very limited, we believe that the aortic procedure of choice should be graft interpositon rather than patch repair.

Aorta, Thoracic↗

Contrast-enhanced magnetic resonance angiography of persistent fifth aortic arch in children.

BACKGROUND: Cine angiography and echocardiography have been utilized to diagnose congenital aortic arch anomalies. However, the visualization of great vessels by echocardiography is limited, while cine angiography requires cardiac catheterization with ionizing radiation. Contrast-enhanced magnetic resonance angiography (MRA) is a noninvasive modality suitable for visualization of congenital aortic arch anomalies. OBJECTIVE: To evaluate the utility of contrast-enhanced MRA in the diagnosis of persistent fifth aortic arch, a rare congenital aortic arch anomaly, and to compare the diagnostic accuracy of MRA with that of echocardiography and cine angiography. MATERIALS AND METHODS: In four pediatric patients, contrast-enhanced MRA studies were performed for diagnosing persistent fifth aortic arch. The findings of MRA were compared with echocardiographic findings and confirmed by cine angiography and operation. RESULTS: Transthoracic surface echocardiography noted an aberrant vessel arising from the ascending aorta in two of four patients; the etiology of this vessel was uncertain. In the other two patients a diagnosis of coarctation was made. Of the four patients, only one was diagnosed with interruption of the aortic arch. Contrast-enhanced MRA clarified uncertain echocardiographic findings, enabling the correct diagnosis of persistent fifth aortic arch with fourth aortic arch interruption in all four patients. CONCLUSION: Contrast-enhanced MRA is a safe, accurate, and fast imaging technique for the evaluation of persistent fifth aortic arch and may obviate the need for conventional cine angiography. Cardiac catheterization may be reserved for some types of complicated congenital heart disease and for obtaining hemodynamic information.

Aorta, Thoracic↗

Antenatal Doppler measurements and early brain injury in very low birth weight infants.

OBJECTIVE: To determine the correlation between fetoplacental blood flow and brain injury and volumes in very low birth weight (VLBW) infants. STUDY DESIGN: Antenatal blood flow from the umbilical artery (UA), middle cerebral artery (MCA), and descending aorta was determined in 70 VLBW infants. The directions of the total diastolic flow of the aortic isthmus and the end-diastolic flow of ductus venosus also were measured. Serial brain ultrasound examinations and MRI at term were performed to assess brain abnormalities. On the basis of brain imaging findings, the newborn infants were classified as normal (n = 14), intermediate brain pathology (n = 31), and major pathology (n = 25) groups. RESULTS: Abnormalities in fetoplacental blood flow were not related to anatomic brain lesions. However, an abnormal UA/MCA pulsatility index ratio was associated with reduced total brain volume (mean, 360 mL; SD, 32.5 mL) and reduced cerebral volume (344 mL; SD, 28.4 mL) compared with infants with normal UA/MCA pulsatility index ratio (mean, 405 mL; SD, 51.3 mL, P = .01, and mean, 368 mL; SD, 52.3 mL, P = .012), respectively. CONCLUSIONS: Redistribution of fetal blood flow in VLBW infants is associated with reduced brain volume at term age. Neurodevelopmental follow-up of this cohort will clarify the significance of these blood flow changes on development.

Aorta, Thoracic↗