PubMed Health⌕ Search

PubMed · 10050124

Rationalization of incisor shape: experimental-numerical analysis.

Abstract

STATEMENT OF PROBLEM: Moving from the posterior segment in the anterior direction within the dental arch, the process of "incisivization" takes place. The occlusal table is gradually replaced by an incisal edge that has the function of cutting. PURPOSE: This study considers these genetically controlled changes by using strain gauge measurements and finite element analyses to rationalize the clinical and biologic advantages of incisal form. A direct clinical link in the common esthetic procedure of anterior veneering is expected. MATERIAL AND METHODS: Six maxillary incisors were mounted in a positioning device and equipped with 2 strain gauges bonded to the palatal surface: gauge 1 (G1) in the concavity and gauge 2 (G2) on the cingulum. A 50 N load was applied on the palatal side of the incisal edge, perpendicular to the long axis of the tooth. Displacement of the load tip and the palatal strain were recorded after successively removing one third, two thirds, and the total thickness of the facial enamel. The same experiment was reproduced with the finite element method (FEM). Four additional experimental designs were tested with the FEM by simulating the progressive thinning and elimination of palatal enamel and a thickened palatal lobe. Surface tangential stresses and local strain in the area corresponding to gauges 1 and 2 were calculated from the postprocessing files. RESULTS: The FEM was validated by experimental results considering both displacement of the load tip ( approximately 120 +/- 30 microm) and tangential surface strain at G1/G2. Recorded strains were always higher in the concavity when compared with the cingulum; high tensile strains were recorded at G1 after the total removal of the facial enamel. The entire facial surface was submitted to compressive forces. Subsequent compressive stresses were higher ( approximately 150 MPa) when facial enamel was thin or when the palatal enamel was removed. However, their absolute value never reached the elevated and potentially harmful tensile stresses measured in the palatal concavity, especially in the absence of facial enamel (272 MPa). Multiple experimental cracks were generated in the remaining palatal enamel as a consequence of stress redistribution. However, smooth and convex surfaces with local enamel bulk such as the cingulum, the marginal ridges, and the facial cervical third of the anatomic crown showed the lowest stress level. The optimal configuration with regard to the stress pattern was given by the modified natural tooth that exhibited thick palatal enamel and a mostly convex palatal surface. CONCLUSIONS: Palatal concavity that provides the incisor with its sharp incisal edge and cutting ability proved to be an area of stress concentration. This shortcoming can be compensated by specific areas that feature thick enamel such as the cingulum and the marginal ridges. When enamel is worn or removed from the facial surface, its replacement should be carried out by using materials with properties similar to enamel to restore the original biomechanical behavior of the tooth.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Magne, A Versluis, W H Douglas. 1999. Rationalization of incisor shape: experimental-numerical analysis.. https://doi.org/10.1016/s0022-3913(99)70279-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A rigorous method for evaluation of the 6D compliance of external fixators.

External fixators are standard devices to stabilize bone fractures and their compliance aims at producing an interfragmentary motion that promotes rapid and successful healing. While evaluation of their axial compliance is a routine test, the quantification and interpretation of their full 6 x 6 compliance matrix is an extensive and delicate task. In this context, the objective of this study was to develop, validate and demonstrate the potential of a rigorous method to quantify their 6 x 6 compliance matrix. An experimental system was developed to apply six independent static forces and moments to an external fixator in the field of view of two infrared cameras quantifying the induced motion. The system was then tested with a calibration structure which compliance could be calculated analytically and numerically. Finally, the system was applied to compare three configurations of a commercial external wrist fixator. The results of the method proved to be reproducible and highly consistent with the linear elasticity theory in the physiological range of small deformations. A rigorous method for evaluation of the 6D compliance becomes therefore available for research in mechanobiology of fracture healing by external fixation.

Compliance↗

Fatigue of packable dental composites.

OBJECTIVE: The purpose of the study was to measure the fatigue properties of four dental resin composites using a dynamic mechanical analysis and to relate the results with viscoelastic properties. METHODS: Dynamic torsional loading was conducted at resonance at 30-50Hz. Specimens were thoroughly cured and tested dry at 21 degrees C. RESULTS: All of the specimens showed a loss of strength following repeated stress, due to material fatigue. The material with the highest shear modulus had the lowest damping and the highest fatigue strength. SIGNIFICANCE: Dental composites exhibit a modest loss of strength due to fatigue. Since mastication involves many cycles of stress during the life of a restoration, fatigue properties should be taken into account in restoration design.

Compliance↗