PubMed HealthSearch

PubMed · 10050828

Tomographic imaging with nonuniform angular sampling.

Abstract

A new class of polar sampling patterns for projection imaging is described. In contrast to conventional techniques, a nonuniform variation of the angular increments between consecutive projections is introduced. The proposed method allows adaptation of the polar sampling pattern to different shapes of the object. Numerical simulations and MR experiments verify that angular sampling density can be varied according to the radial extension of the object, resulting in a reduction of the total number of required projections (and X-ray exposure) compared with conventional circular field-of-view imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Scheffler. Tomographic imaging with nonuniform angular sampling.. https://doi.org/10.1097/00004728-199901000-00032

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Longitudinal image deblurring in spiral CT.

PURPOSE: To assess the feasibility of digital deconvolution techniques to improve longitudinal resolution of spiral computed tomography (CT) multiplanar reformations and evaluate how technical factors in deconvolution affect longitudinal resolution, noise, and edge ringing. MATERIALS AND METHODS: Longitudinal line spread function (LSF) of the system was estimated from longitudinal reformations of transaxial spiral CT images of a step test phantom. By using the estimated LSF, longitudinal reformations of the phantom and three clinical spiral CT studies were deconvolved by the methods of Wiener filtering and constrained iterative deconvolution. Edge ringing and image noise were quantified for Wiener filtering and constrained iterative deconvolution. RESULTS: Longitudinal reformations were substantially deblurred and resolution improved after deconvolution. Anatomic boundaries in clinical images were more clearly delineated after restoration. The methods of Wiener deconvolution and constrained iterative deconvolution improved the sharpness of the phantom step boundary at the expense of increased edge ringing and image noise. CONCLUSION: In longitudinal spiral CT reformations, blurring along the longitudinal axis can be reduced by Wiener filtering or constrained iterative deconvolution.

Technology, Radiologic

Re: Film processing.

Explore the source record for details and available documents.

Technology, Radiologic