PubMed Health⌕ Search

PubMed · 10052632

Automatic quantification of microvessels using unsupervised image analysis.

Abstract

An automatic method for quantification of images of microvessels by computing area proportions and number of objects is presented. The objects are segmented from the background using dynamic thresholding of the average component size histogram. To be able to count the objects, fragmented objects are connected, all objects are filled, and touching objects are separated using a watershed segmentation algorithm. The method is fully automatic and robust with respect to illumination and focus settings. A test set consisting of images grabbed with different focus and illumination for each field of view, was used to test the method, and the proposed method showed less variation than the intraoperator variation using manual threshold. Further, the method showed good correlation to manual object counting (r = 0.80) on an other test set.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Ranefall, K Wester, C Busch, P U Malmström, E Bengtsson. 1998. Automatic quantification of microvessels using unsupervised image analysis.. https://doi.org/10.1155/1998%2F490585

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An automatic 96-well solid phase extraction and liquid chromatography-tandem mass spectrometry method for the analysis of morphine, morphine-3-glucuronide and morphine-6-glucuronide in human plasma.

A bioanalytical method using automated sample transferring, automated solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed for morphine (MOR), and its metabolites morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G) in human plasma. Samples of 0.25 ml were transferred into 96-well plate using automatic liquid handler (Multiprobe II). Automated SPE was carried out on a 96-channel programmable liquid handling workstation (Quadra 96) using a C(18) sorbent. The extract was injected onto a silica column using an aqueous-organic mobile phase. The chromatographic run time was 3.5 min per injection, with retention times of 1.5, 2.0 and 2.6 min for MOR, M6G, and M3G, respectively. The detection was by monitoring MOR at m/z 286-->152, M6G and M3G at m/z 462-->286. The deuterated internal standards were monitored at m/z 289-->152 for MOR-d(3), and m/z 465-->289 for M6G-d(3) and M3G-d(3). The standard curve range was 0.5-50 ng ml(-1) for MOR, 1.0-100 ng ml(-1) for M6G, and 10-1000 ng ml(-1) for M3G. The inter-day precision and accuracy of the quality control samples were <8% relative standard deviation (RSD) and <7% relative error (RE) for MOR, <5% RSD and <2% RE for M6G, and <2% RSD and <4% RE for M3G.

Automation↗

RiceGAAS: an automated annotation system and database for rice genome sequence.

An extensive effort of the International Rice Genome Sequencing Project (IRGSP) has resulted in rapid accumulation of genome sequence, and >137 Mb has already been made available to the public domain as of August 2001. This requires a high-throughput annotation scheme to extract biologically useful and timely information from the sequence data on a regular basis. A new automated annotation system and database called Rice Genome Automated Annotation System (RiceGAAS) has been developed to execute a reliable and up-to-date analysis of the genome sequence as well as to store and retrieve the results of annotation. The system has the following functional features: (i) collection of rice genome sequences from GenBank; (ii) execution of gene prediction and homology search programs; (iii) integration of results from various analyses and automatic interpretation of coding regions; (iv) re-execution of analysis, integration and automatic interpretation with the latest entries in reference databases; (v) integrated visualization of the stored data using web-based graphical view. RiceGAAS also has a data submission mechanism that allows public users to perform fully automated annotation of their own sequences. The system can be accessed at http://RiceGAAS.dna.affrc.go.jp/.

Automation↗