PubMed Health⌕ Search

PubMed · 10063336

Monitoring respiratory muscles.

Abstract

The respiratory system consists of two main parts, the lung and the ventilatory pump. The latter consists of the bony structure of the thorax, the central respiratory controllers, the inspiratory and expiratory muscles, and the nerves innervating these muscles. Respiratory muscle fatigue occurs when respiratory muscle endurance is exceeded. Muscle fatigue is defined as a condition in which there is a reduction in the capacity for developing force and/or velocity of a muscle, resulting from muscle activity, and which is reversible by rest. The respiratory muscles are somewhat difficult to assess and the techniques employed are still relatively primitive. The most important methods of respiratory muscles function assessment are: 1) the vital capacity manoeuvre, which depends on maximum inspiratory and expiratory effort by the muscles and may be a useful indicator of respiratory muscle function; 2) radiological screening has been proposed for the detection of diaphragm paralysis. This may be helpful if the paralysis is unilateral, but bilateral paralysis is difficult to detect; and 3) respiratory muscles strength may be assessed with either voluntary or nonvoluntary manoeuvres. The function of the inspiratory muscles is assessed with 3 voluntary dependent manoeuvres. They are the so called Müller manoeuvre (or maximal inspiratory pressure), the sniff test and the combined test. All these three manoeuvres generate a pressure that is a reflection of complex interactions between several muscle groups since the efforts produce different mechanisms of activity of inspiratory and expiratory muscles. Two techniques are presently employed to assess diaphragm function, not being dependent on the patient's motivation: electrical phrenic nerve stimulation and cervical magnetic stimulation. Since it is less painful, magnetic cervical stimulation overcomes some of the difficulties encountered during electrical stimulation. With these two techniques recordings of diaphragmatic force are possible, and at the same time useful information about the conduction time of both phrenic nerves can be obtained.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Nava. 1998. Monitoring respiratory muscles.. https://pubmed.ncbi.nlm.nih.gov/10063336/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT.

PURPOSE: To investigate temporospatial variations of tumor and normal tissue during respiration in lung cancer patients. METHODS AND MATERIALS: In 14 patients, gross tumor volume (GTV) and normal tissue structures were manually contoured on four-dimensional computed tomography (4D-CT) scans. Structures were evaluated for volume changes, centroid (center of mass) motion, and phase dependence of variations relative to inspiration. Only volumetrically complete structures were used for analysis (lung in 2, heart in 8, all other structures in >10 patients). RESULTS: During respiration, the magnitude of contoured volumes varied up to 62.5% for GTVs, 25.5% for lungs, and 12.6% for hearts. The range of maximum three-dimensional centroid movement for individual patients was 1.3-24.0 mm for GTV, 2.4-7.9 mm for heart, 5.2-12.0 mm for lungs, 0.3-5.5 mm for skin markers, 2.9-10.0 mm for trachea, and 6.6-21.7 mm for diaphragm. During respiration, the centroid positions of normal structures varied relative to the centroid position of the respective GTV by 1.5-8.1 mm for heart, 2.9-9.3 mm for lungs, 1.2-9.2 mm for skin markers, 0.9-7.1 mm for trachea, and 2.7-16.4 mm for diaphragm. CONCLUSION: Using 4D-CT, volumetric changes, positional alterations as well as changes in the position of contoured structures relative to the GTV were observed with large variations between individual patients. Although the interpretation of 4D-CT data has considerable uncertainty because of 4D-CT artifacts, observer variations, and the limited acquisition time, the findings might have a significant impact on treatment planning.

Diaphragm↗

Brief review: Neuromuscular monitoring: an update for the clinician.

PURPOSE: To review established techniques and to provide an update on new methods for clinical monitoring of neuromuscular function relevant to anesthesia. SOURCE: A PubMed search of relevant article for the period 1985-2005 was undertaken, and bibliographies were scanned for additional sources. PRINCIPAL FINDINGS: There is no substitute for objective neuromuscular monitoring; for research purposes, mechanomyography (MMG) is the gold standard; however, the most versatile method in the clinical setting is acceleromyography since it can be applied at various muscles and has a long track record of clinical utility. Kinemyography is valid to monitor recovery of neuromuscular transmission at the adductor pollicis muscle (AP), whereas phonomyography is easy to apply to various muscles and shows promising agreement with MMG. Monitoring of the corrugator supercilii muscle (CS) may be used to determine the earliest time for tracheal intubation as it reflects laryngeal relaxation better than monitoring at the AP. Recovery of neuromuscular transmission is best monitored at the AP, since it is the last muscle to recover from neuromuscular blockade (NMB). If train-of-four (TOF) stimulation is used, a TOF-ratio > 0.9 should be the target before awakening the patient. If surgery or the type of anesthesia necessitates NMB of a certain degree, e.g., TOF-ratio = 0.25, monitoring of muscles which best reflect the degree of NMB at the surgical site is preferable. CONCLUSION: Objective methods should be used to monitor neuromuscular function in clinical anesthesia. Acceleromyography offers the best compromise with respect to ease of use, practicality, versatility, precision and applicability at various muscles. The CS is the optimal muscle to determine the earliest time for intubation, e.g., for rapid sequence induction.

Diaphragm↗