PubMed HealthSearch

PubMed · 10065962

Tryptic digest mapping by gradient capillary electrochromatography.

Abstract

A high performance liquid chromatography (HPLC) system complemented with T-split, capillary detection cell and a high voltage power supply was used for peptide mapping by gradient electrochromatography and nanoliquid chromatography (nano-LC). With capillary columns of 100 microm ID, 6 cm packed with octadecylated 1.5 microm silica particles, the typical analysis time was approximately 10-15 min. The resolution of a tryptic digest of cytochrome c obtained by electrochromatography at 100 kV/m was superior compared to the analysis by nano-LC. Bubble formation caused by Joule heating at currents up to 100 microA was successfully suppressed by using a resistor capillary of 25 microm ID connected to the outlet of the packed column.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Behnke, J W Metzger. 1999. Tryptic digest mapping by gradient capillary electrochromatography.. https://doi.org/10.1002/(sici)1522-2683(19990101)20%3A1%3C80%3A%3Aaid-elps80%3E3.0.co%3B2-i

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

High-temperature ultrafast liquid chromatography.

A novel liquid chromatographic system which enables high temperature ultrafast liquid chromatography (HTU-FLC) has been designed through the careful consideration of heat transfer, band broadening, and pressure drop. Studies of the effect of linear velocity on the HETP show that column efficiency at high velocity, especially of well-retained solutes, dramatically improves at higher temperatures. At 150 degrees C, at a flow rate of 15 mL/min with a 5 cm by 4.6 mm (i.d.) column packed with 3 microns polystyrene-coated zirconia porous particles, long chain alkylphenones were completely resolved, and the analysis time could be decreased by a factor of 50 compared to that at room temperature (25 degrees C) at a conventional flow rate (4 mL/min). In addition, using pure water as the mobile phase, five phenols were separated in less than 30 s.

Chromatography, Liquid

New fluorimetric method of liquid chromatography for the determination of the neurotoxin domoic acid in seafood and marine phytoplankton.

Domoic acid (DA) is a neurotoxic amino acid that is responsible for the human toxic syndrome, amnesic shellfish poisoning (ASP). A new rapid, sensitive liquid chromatographic (LC) method has been developed for the determination of DA in various marine samples. DA in marine biological materials was derivatised with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) and analysed using isocratic reversed-phase LC with fluorimetric detection. The calibration, based on standard DA solutions, was linear in the range 0.04-2 microg/ml (r2=0.998) and the detection limit (3:1, signal/noise) was better than 1 ng/ml. Using the certified reference material (MUS-1B), recoveries of DA from shellfish tissue were >95% (n=5). When a strong anion exchange SPE cartridge was used for sample clean-up the detection limit was 6 ng DA/g mussel tissue. Good reproducibility was achieved with RSD values ranging from 3% for 8 microg DA/g (n=5), to 5% for 0.04 microg DA/g (n=5). This new method was successfully applied to the determination of DA in naturally contaminated shellfish and in marine phytoplankton cultures of Pseudonitzschia sp.

Chromatography, Liquid

Enantioselective analysis of methadone in saliva by liquid chromatography-mass spectrometry.

Saliva was tested and evaluated as a biological matrix for methadone (Mtd) monitoring. Conventional method using a narrow bore C18 column, and an enantioselective method using a narrow bore alpha1-acid glycoprotein column, were developed using liquid chromatography coupled with a mass spectromeric (MS) detector. After optimisation of MS conditions by flow injection analysis, selected ion monitoring detection was used to enhance sensitivity. The total Mtd concentration and the enantiomeric ratio in saliva were validated using an experimental design. The methods were applied to samples provided by heroin addicts undergoing a Mtd treatment. Results on total Mtd determination showed a very poor correlation between saliva and serum, whereas the enantiomeric ratios of Mtd gave a very good one.

Chromatography, Liquid