PubMed Health⌕ Search

PubMed · 10075906

Colorimetric protein assay techniques.

Abstract

There has been an increase in the number of colorimetric assay techniques for the determination of protein concentration over the past 20 years. This has resulted in a perceived increase in sensitivity and accuracy with the advent of new techniques. The present review considers these advances with emphasis on the potential use of such technologies in the assay of biopharmaceuticals. The techniques reviewed include Coomassie Blue G-250 dye binding (the Bradford assay), the Lowry assay, the bicinchoninic acid assay and the biuret assay. It is shown that each assay has advantages and disadvantages relative to sensitivity, ease of performance, acceptance in the literature, accuracy and reproducibility/coefficient of variation/laboratory-to-laboratory variation. A comparison of the use of several assays with the same sample population is presented. It is suggested that the most critical issue in the use of a chromogenic protein assay for the characterization of a biopharmaceutical is the selection of a standard for the calibration of the assay; it is crucial that the standard be representative of the sample. If it is not possible to match the standard with the sample from the perspective of protein composition, then it is preferable to use an assay that is not sensitive to the composition of the protein such as a micro-Kjeldahl technique, quantitative amino acid analysis or the biuret assay. In a complex mixture it might be inappropriate to focus on a general method of protein determination and much more informative to use specific methods relating to the protein(s) of particular interest, using either specific assays or antibody-based methods. The key point is that whatever method is adopted as the 'gold standard' for a given protein, this method needs to be used routinely for calibration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C V Sapan, R L Lundblad, N C Price. 1999. Colorimetric protein assay techniques.. https://pubmed.ncbi.nlm.nih.gov/10075906/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Selective and sensitive colorimetric sensing of carbosulfan based on BiO2-x/Bi2O2.75 nanosheets with excellent haloperoxidase-like activity.

The development of colorimetric methods based on directly inhibiting nanozyme activity for pesticide detection has attracted considerable attention. In this study, we report a novel colorimetric sensing strategy utilizing BiO2-x/Bi2O2.75 nanosheets (BiO2-x/Bi2O2.75 NSs) with haloperoxidase (HPO)-like activity for the rapid and sensitive detection of carbosulfan (CBS) in foods. Oxygen-vacancy-rich BiO2-x/Bi2O2.75 NSs with HPO-like activity were rationally constructed. Kinetic studies revealed a remarkable Michaelis-Menten constant (Km) of 0.014 mM for I-, indicating a higher affinity for iodide ions than other reported HPO-like nanozymes, as evidenced by its lower Km. Under acidic conditions, CBS tends to be hydrolyzed to produce reductive sulfide species, which directly inhibit the iodoperoxidase-like activity of BiO2-x/Bi2O2.75 NSs, enabling selective detection with a limit of detection (LOD) of 0.18 μg/mL and a linear range of 0.20-100 μg/mL. When the concentration of interfering pesticides and substances was 5 times that of CBS, the sensor remained unaffected, exhibiting excellent stability and specificity. This work contributes to the detection of CBS in complex food matrices, bridging the application gap of HPO-like nanozymes in pesticide detection and providing a promising method for food safety detection.

Colorimetry↗

Modification of the Stewart biphasic colorimetric assay for stable and accurate quantitative determination of Pluronic and Tetronic block copolymers for application in biological systems.

Block copolymers are increasingly being applied in areas such as transfection, membrane sealing, site-specific targeting, and bionanoengineering yet there is a relative paucity of assays available for simple, stable and reproducible colorimetric determination of copolymer concentration in solution. We have focused on improving the accuracy and reproducibility of a modified version of the Stewart biphasic colorimetric assay for quantitative determination of Pluronic (poloxamer) and Tetronic (poloxamine) macromolecules. The optimized assay achieved linear response ranges in chloroform for commonly used copolymers such as poloxamine 904 (20-300 microg/ml), poloxamine 908 (10-400 microg/ml), poloxamer 402 (20-400 microg/ml), and poloxamer 407 (10-400 microg/ml). Variation in the type of chlorinated solvent used significantly increased assay sensitivity, presumably through macromolecular reorientation, affording increased access for copolymer-ferrothiocyanate complexation. This was found to be optimally favored by the planar geometry of the solvent cis 1,2-dichloroethylene. For application to biological systems copolymer-protein interactions were for the first time determined and were found to be dependent on the fraction of hydrophobic constituents of the block copolymers and protein type. For instance serum albumin was found to interact with copolymers of low hydrophilic-lipophilic balance values and poly(propylene oxide) contaminants, whereas this interaction was not significant with the relatively hydrophilic IgG. In such systems the colorimetric assay directly determines the fraction of unbound (free) copolymer in the presence of proteins.

Colorimetry↗