PubMed Health⌕ Search

PubMed · 10132261

Project management.

Abstract

High priority projects need to be treated as more than just another element in the normal managerial process if they are to be implemented on time, achieve their quality targets, and finish within budget. Achieving this discipline is the object of 'project management'--an approach which uses special control structures and management techniques to make things happen. Can this approach help your organisation move faster with strategically important one-off projects? This Health Management Guide looks at why project management is necessary, explores a number of case studies where it has been used successfully in the health services, and identifies the key points to bear in mind when adopting this approach.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1994-02-03. Project management.. https://pubmed.ncbi.nlm.nih.gov/10132261/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Beam intensity modulation using tissue compensators or dynamic multileaf collimation in three-dimensional conformal radiotherapy of primary cancers of the oropharynx and larynx, including the elective neck.

INTRODUCTION: The treatment of midline tumors in the head and neck by conventional radiotherapy almost invariably results in xerostomia. This study analyzes whether a simple three-dimensional conformal radiotherapy (3D-CRT) technique with beam intensity modulation (BIM) (using a 10-MV beam of the MM50 Racetrack Microtron) can spare parotid and submandibular glands without compromising the dose distribution in the planning target volume (PTV). METHODS: For 15 T2 tumors of the tonsillar fossa with extension into the soft palate (To) and 15 T3 tumors of the supraglottic larynx (SgL), conventional treatment plans, consisting of lateral parallel opposed beams, were used for irradiation of both the primary tumor (70 Gy) and the elective neck regions (46 Gy). Separately, for each tumor a 3-D conformal treatment plan was developed using the 3-D computer planning system, CadPlan, and Optimize, a noncommercial program to compute optimal beam profiles. Beam angles were selected with the intention of optimal sparing of the salivary glands. The intensity of the beams was then modulated to achieve a homogeneous dose distribution in the target for the given 3D-CRT techniques. The dose distributions, dose-volume histograms (DVHs) of target and salivary glands, tumor control probabilities (TCPs), salivary gland volumes absorbing a biologically equivalent dose of greater than 40 or 50 Gy, and normal tissue complication probabilities (NTCPs) of each treatment plan were computed. The parameters of the 3D-CRT plans were compared with those of the conventional plans. RESULTS: In comparison with the conventional technique, the dose homogeneity in the target volume was improved by the conformal technique for both tumor sites. In addition, for the SgL conformal technique, the average volumes of the parotid glands absorbing a BED of greater than 40 Gy (V40) decreased by 23%, and of the submandibular glands by 7% (V40) and 6% (V50). Consequently, the average NTCPs for the parotid and submandibular glands were reduced by 7% and 6%, respectively. For the To conformal techniques, the V40 of the parotid glands was decreased on average by 31%, resulting in an average reduction of the NTCP by 49%. Both the average V50 and the NTCP of the submandibular glands were decreased by 7%. CONCLUSION: For primary tumors of the oropharynx, the parotid glands could be spared to a considerable degree with the 3D-CRT technique. However, particularly the ipsilateral submandibular gland could not be spared. For primary tumors of the larynx, the 3D-CRT technique allows sparing of all salivary glands to a considerable and probably clinically relevant degree. Moreover, the conformal techniques resulted in an increased dose homogeneity in the PTV of both tumor sites.

Feasibility Studies↗

3-D portal image analysis in clinical practice: an evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients.

PURPOSE: To investigate the clinical importance and feasibility of a 3-D portal image analysis method in comparison with a standard 2-D portal image analysis method for pelvic irradiation techniques. METHODS AND MATERIALS: In this study, images of 30 patients who were treated for prostate cancer were used. A total of 837 imaged fields were analyzed by a single technologist, using automatic 2-D and 3-D techniques independently. Standard deviations (SDs) of the random, systematic, and overall variations, and the overall mean were calculated for the resulting data sets (2-D and 3-D), in the three principal directions (left-right [L-R], cranial-caudal [C-C], anterior-posterior [A-P]). The 3-D analysis included rotations as well. For the translational differences between the three data sets, the overall SD and overall mean were computed. The influence of out-of-plane rotations on the 2-D registration accuracy was determined by analyzing the difference between the 2-D and 3-D translation data as function of rotations. To assess the reliability of the 2-D and 3-D methods, the number of times the automatic match was manually adjusted was counted. Finally, an estimate of the workload was made. RESULTS: The SDs of the random and systematic components of the rotations around the three orthogonal axes were 1. 1 (L-R), 0.6 (C-C), 0.5 (A-P) and 0.9 (L-R), 0.6 (C-C), 0.8 (A-P) degrees, respectively. The overall mean rotation around the L-R axis was 0.7 degrees, which deviated significantly from zero. Translational setup errors were comparable for 2-D and 3-D analysis (ranging from 1.4 to 2.2 mm SD and from 1.5 to 2.5 mm SD, respectively). The variation of the difference between the 2-D and 3-D translation data increased from 1.1 mm (SD) for zero rotations to 2.7 mm (SD) for out-of-plane rotations of 3 degrees, due to a reduced 2-D registration accuracy for large rotations. The number of times the analysis was not considered acceptable and was manually adjusted was 44% for the 2-D analysis, and 6% for the 3-D analysis. CONCLUSION: True 3-D analysis of setup errors for a group of 30 patients with prostate cancer demonstrated that setup rotations are rather small. The deformation of the projected anatomy in portal images caused by out-of-plane rotations leads to a reduced 2-D registration accuracy. For rotations larger than 3 degrees this effect can be quite pronounced, making 3-D registration the preferred method. Furthermore, the automatic 3-D registration has a higher success rate, most likely because this technique uses more information compared to the 2-D method.

Feasibility Studies↗

A multidisciplinary approach to assess history, environmental risks, and remediation feasability of soils contaminated by metallurgical activities. Part A: chemical and physical properties of metals and leaching ability.

Three soils contaminated by heavy metals (HMs) and aliphatic hydrocarbons originating from different industrial sources were characterized in a multidisciplinary study combining chemical, physical (Part A), and mineralogical (Part B) approaches to define history, environmental risks, and remediation feasibility. These were an agricultural soil located nearby a Zn/Pb smelter and two soils from a steel metallurgical (siderurgy) waste land. High Pb and Zn contents were reported for all, and high Cr, Cd, and aliphatic hydrocarbons were present in different combinations in two out of three soils. Carbonate matrixes more strongly cemented fine particles in the agricultural soil than in both siderurgical ones, but buffering capacities were stronger in the latter. After the disruption of these cements by ultrasounds, HM were concentrated in the <50-microm fraction of the agricultural and of one siderurgical soil. Sequential extractions indicated for all the soils a preferential association of HM with carbonates, Fe-Mn oxides, organic matter, and sulfides. The stirring of one siderurgical soil with water resulted in an immediate leaching of hexavalent chromium (0.3 mg x L(-1)) involving potential ecotoxicological risks.

Feasibility Studies↗