PubMed Health⌕ Search

PubMed · 10149583

Valvular surgery.

Abstract

The collection of clinical cardiac surgical articles published in the last year about valvular heart disease emphasizes the continuing accrual of data that compare prosthetic and bioprosthetic valves and suggest advantages and disadvantages of both: the indications for and long-term results of aortic valve replacement, particularly in patients with left ventricular dysfunction; newer elements of mitral valve reconstruction; and debate about the best operation for the tricuspid valve. A miscellaneous collection of interesting articles discusses endocarditis and anticoagulation in the pregnant patient who undergoes heart surgery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L H Cohn. 1991. Valvular surgery.. https://doi.org/10.1097/00001573-199104000-00010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Strength testing of pins made of human femur cortical bone].

For biomechanical evaluation of cortical bone as a potential source for internal fixation devices, pins of 2 and 3 mm in diameter were made from fresh human femora and subjected to bending loads. Some of the pins were tested without further treatment; others were defatted and dried in acetone solution. Of the acetone-treated pins, some were autoclaved either at 121 degrees C for 20 min or at 134 degrees C for 8 min. Acetone treatment of the pins caused a 5.5% increase in bending strength (p < or = 0.05) and a 6.6% increase in the elastic modulus (p < or = 0.05). The mean bending strength of the acetone-treated pins was 257 +/- 52 N/mm2 and the mean elastic modulus was 18,346 +/- 1292 N/mm2. Autoclaving of the pins at the lower temperature for a longer time led to a decrease in the bending strength of up to 16% and at the higher temperature for a shorter time to a decrease of up to 41%. To compare the strengths of the cortical and synthetic pins, 2-mm Biofix pins were also tested. The Biofix pins showed a 25% higher bending strength than the acetone-treated pins but a 12.5% lower elastic modulus. It should be noted that in animal studies the synthetic Biofix pins showed a 20% loss of strength within 2 days after implantation in situ.

Bioprosthesis↗

Artificial mitral valve chordae replacement made simple.

Mitral valve repair techniques are now widely applied in patients with myxomatous valve disease. The use of artificial chords to achieve correct height adjustment of the prolapsing anterior leaflet segment can often be challenging. We describe a simple method of artificial chord reconstruction performed after annuloplasty, which allows for easy identification of functional prolapse and accurate chordal height adjustment.

Bioprosthesis↗