PubMed Health⌕ Search

PubMed · 10150973

Progress in interventional cardiology.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H J Geschwind, J D Talley. 1992. Progress in interventional cardiology.. https://doi.org/10.1111/j.1540-8183.1992.tb00839.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Excimer laser thrombus elimination for prevention of distal embolization and no-reflow in patients with acute ST elevation myocardial infarction: results from the randomized LaserAMI study.

BACKGROUND: Results for standard revascularization therapies in acute myocardial infarction (AMI) have been limited in part by distal embolization, a process which might be reduced by the application of ultraviolet laser light. The aim was to assess feasibility and safety of excimer laser coronary angioplasty (ELCA) in a randomized study in AMI. METHODS: Twenty-seven consecutive patients with ST-segment elevation AMI (aged 57.8+/-9.2 years) were randomized either to balloon angioplasty and stent implantation alone (n=13) or adjunct ELCA (n=14). Quantitative coronary angiography was analyzed by an independent core laboratory. RESULTS: ELCA was feasible and safe in all cases. No procedure-associated complications were observed. Similar results were found for main parameters in laser (L) and control (C) patients: diameter stenosis decreased from 94.3+/-9.6 to 20.7+/-10.3% (L) and from 82.7+/-16.8 to 18.9+/-5.5% (C) (p=ns; L vs. C). TIMI flow increased from 0.7+/-1.2 to 2.8+/-0.4 and from 1.7+/-1.5 to 3.0+/-0 (p=ns; L vs. C), respectively. The post-procedural myocardial blush score did not differ between the groups (2.1+/-1.3 and 2.7+/-1.0; p=ns; L vs. C) and the final corrected TIMI frame count (cTFC) was also similar in both groups (23+/-7 and 22+/-4; p=ns; L vs. C), but the cTFC gain was higher in the laser group (53+/-14% and 35+/-20%; p<0.05; L vs. C). CONCLUSIONS: Laser angioplasty is feasible and safe for the treatment of patients with ST elevation AMI. Procedural results were at least on par with conventional treatment. Further randomized controlled trials are needed to assess the benefit of laser angioplasty in AMI.

Angioplasty, Balloon, Laser-Assisted↗

Delayed strut fracture of sirolimus-eluting stent: a significant problem or an occasional observation?

In-stent restenosis after implantation of sirolimus-eluting stents (SES) still occur in some cases and stent fracture was recently suggested as a new potential mechanism of restenosis. We report a case of delayed stent strut fracture after percutaneous coronary intervention with SES. Until now, three cases regarding Cypher stent fracture have been reported in the literature. Further investigation should be performed to elucidate the clinical significance of stent fractures of SES.

Angioplasty, Balloon, Laser-Assisted↗

[Non-contact donor cornea trephination with a flying spot excimer laser system].

BACKGROUND: One of the most common complications after mechanical penetrating keratoplasty is the occurrence of irregular astigmatism. We developed a method to prepare donor grafts for transplantation applying excimer laser techniques. The quality of the cut edges and exposure time were evaluated. MATERIALS AND METHODS: The beam of an experimental excimer laser (OPTex, Lambda Physik) was homogenized and guided by an optical system including lenses and scanner mirrors. A special software was used to conduct the laser beam in a circular mode over the surface of the cornea. Corneas from porcine eyes were stabilized in an artificial anterior chamber. Twenty in vitro explants were trephinated applying our method and subsequently investigated by electron microscopy and histology. RESULTS: All experiments provided regular and smooth cut edges. The average exposure time until perforation was 10.5 min (SD 2.7 min), the diameter of the grafts was 8.0 mm. CONCLUSION: The experiments showed the possibility of non-contact trephination and generation of smooth cut edges with a rotating focussed excimer laser beam in a porcine cornea model. A major advantage of the system is the possibility of customized "tailored" grafts.

Angioplasty, Balloon, Laser-Assisted↗