Using patient outcomes to screen for clinical laboratory errors.

Abstract

How to measure the quality of laboratory testing has long been a challenging problem for laboratory managers and accrediting agencies. Traditionally, laboratory quality has been assessed by direct inspection, proficiency testing, and the credentials of staff. None of these methods is entirely satisfactory at answering a fundamental question: does the laboratory give technically accurate and clinically meaningful information for each patient that it tests? This paper discusses how information on patient outcomes can be used to screen for laboratories that may be making frequent random or systematic errors. This approach is called downstream event monitoring (DEM). The basic idea is to look at what happens to a laboratory's patients in a critical window of time after they have been tested. The approach carries out a basic adage of quality management: follow up with your customers to see if your product has met their needs. The main idea of DEM is that if a laboratory has not conveyed accurate information, the clinician may take actions that fail to help, or maybe even harm, the patient. If a laboratory's patients have an unusually high rate of adverse events that happen within a window of time when the laboratory test would have played a critical role, the laboratory should be further examined to see if it is the cause of the problem. Right now, DEM is a technique under development. It needs a clinical logic to relate a patient's outcomes back to a laboratory test, and it needs good data to compare laboratories. This paper discusses how the prothrombin time test and the serum digoxin test have been examined for Medicare patients to see if certain laboratory characteristics are associated with unusually high occurrences of adverse events after testing. The need for future validation studies is also discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J W Winkelman, S T Mennemeyer. Using patient outcomes to screen for clinical laboratory errors.. https://pubmed.ncbi.nlm.nih.gov/10172598/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of temperature on the extraction kinetics and diffusivity of Cyclosporin A in the fungus Tolypocladium inflatum.

The influence of temperature on the extraction kinetics of Cyclosporin A (CyA) from the mycelia of Tolypocladium inflatum was examined in this study. The extraction of CyA from mycelia was performed in a 2-L stirred, baffled vessel using 30% v/v aqueous methanol. The temperature range used was from 5 to 45 degrees C. A linear relationship was found between the extraction yield of CyA and temperature. As the temperature increased, the yield of CyA increased with a maximum CyA yield of 18.3% obtained at 45 degrees C, which is 21.3% higher than the yield at 25 degrees C. The activation energy for the extraction of CyA from T. inflatum was found to be 36.7 kJ/mol, which indicates that the extraction of CyA from T. inflatum is controlled by both solubilization of CyA and diffusion of CyA through the solid phase of mycelia. The overall mass transfer coefficient, k(L)a(S), was found to increase from 1.02 x 10(-3) to 1.34 x 10(-2) s(-1) as the temperature increased from 5 to 45 degrees C. The effective diffusivity of CyA in the solid matrix of mycelia was found to increase from 1.05 x 10(-15) to 1.43 x 10(-14) m(2)/s as the temperature increased from 5 to 45 degrees C. A mathematical diffusion model was developed and was used to fit the experimental kinetic data of CyA extraction and determination of CyA effective diffusivities at different temperatures. This is the first time CyA diffusivities as a function of extraction temperature are reported in the literature.

Clinical Laboratory Techniques↗

Laboratory-confirmed non-O157 Shiga toxin-producing Escherichia coli--Connecticut, 2000-2005.

Shiga toxin-producing Escherichia coli (STEC) infection causes diarrhea that is often bloody and can result in potentially life-threatening hemolytic uremic syndrome (HUS). Escherichia coli O157:H7 is the most common cause of STEC infection in the United States, producing 73,000 illnesses annually, according to the last estimate in 1999. Unlike O157, however, little is known about the incidence of non-O157 strains. Because STEC other than O157 are not commonly identified, the incidence, trends, and epidemiology of non-O157 STEC are not well understood. To assess trends in Shiga toxin enzyme immunoassay (Stx EIA) testing by local clinical laboratories, the Connecticut Department of Public Health (CTDPH) analyzed results of confirmatory testing conducted in the state laboratory during 2000--2005. The findings indicated that a total of 403 STEC infections were reported by clinical laboratories in Connecticut, including 207 identified as STEC by Stx EIA testing alone, and that the use of Stx EIA increased from 2000 to 2005. Use of Stx EIA without prompt culture confirmation can delay or prevent serotyping and subtyping of isolates and detection of both O157 and non-O157 STEC outbreaks. Public health authorities in all states should ensure that clinical laboratories forward Stx EIA-positive specimens to the state laboratory for isolation and identification of STEC, as recommended by the Association of Public Health Laboratories and CDC.

Clinical Laboratory Techniques↗

Clinical use of laboratory tests for the identification of secondary forms of arterial hypertension.

The prevalence of secondary hypertension can be underestimated if appropriate tests are not performed. The importance of selecting patients with a high pre-test probability of secondary forms of hypertension is first discussed. The laboratory tests currently used for seeking a cause of hypertension are critically reviewed, with emphasis on their operative features and limitations. Strategies to identify primary aldosteronism, the most frequent form of secondary hypertension, and to determine its unilateral or bilateral causes are described. Treatment entails adrenalectomy in unilateral forms, and mineralocorticoid receptor blockade in bilateral forms. Renovascular hypertension is also a common, curable form of hypertension, that should be identified as early as possible to avoid the onset of cardiovascular target organ damage. The tests for its confirmation or exclusion are discussed. The various tests available for the diagnosis of pheochromocytoma, which is much rarer than the above but extremely important to identify, are also described, with emphasis on recent developments in genetic testing. Finally, the tests for diagnosing some rarer monogenic forms and other renal and endocrine causes of arterial hypertension are explored.

Clinical Laboratory Techniques↗