Implantable stimulation system dedicated for neural selective stimulation.

Abstract

A functional electrical stimulation system is presented, which is dedicated for the selective neural stimulation of the bladder. The proposed system is composed of an internal stimulator (implant) and an external controller. The system is used to produce low-pressure voiding of the bladder in spinal cord injured patients. The implant is powered and operated by the external controller via radio-frequency electromagnetic coupling. All stimulation parameters are chosen externally using the controller and are sent to the implant, which produces the desired stimuli. These stimuli are applied directly to the S2 nerve which is linked to the sphincter and bladder muscles. A high-frequency signal is used to inhibit the contraction of the sphincter muscle, and low-frequency pulses stimulate the bladder muscle (the detrusor). Dedicated computer software is used by the physician to select the optimal parameters for each patient and to activate the implant through a parallel port interface with built-in transmitter. The parameters are then transferred to a hand-held controller which is used by the technical staff and by the patients themselves. Acute studies have been performed to validate the selective stimulation strategy, and chronic experimentation is currently underway in dogs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Robin, M Sawan, M Abdel-Gawad, T M Abdel-Baky, M M Elhilali. 1998. Implantable stimulation system dedicated for neural selective stimulation.. https://doi.org/10.1007/bf02523220

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modeling biological motor control for human locomotion with functional electrical stimulation.

This paper develops a novel control system for functional electrical stimulation (FES) locomotion, which aims to generate normal locomotion for paraplegics via FES. It explores the possibility of applying ideas from biology to engineering. The neural control mechanism of the biological motor system, the central pattern generator, has been adopted in the control system design. Some artificial control techniques such as neural network control, fuzzy logic, control and impedance control are incorporated to refine the control performance. Several types of sensory feedback are integrated to endow this control system with an adaptive ability. A musculoskeletal model with 7 segments and 18 muscles is constructed for the simulation study. Satisfactory simulation results are achieved under this FES control system, which indicates a promising technique for the potential application of FES locomotion in future.

Electric Stimulation Therapy↗

Complications and troubleshooting of two-stage sacral neuromodulation therapy: a single-institution experience.

OBJECTIVES: With the increasing use of sacral neuromodulation therapy, urologists are faced with postimplantation challenges. The purpose of this study was to identify these events and their causes and management in our large single-institution experience. METHODS: From July 2002 to September 2004, all patients who underwent sacral neuromodulation therapy for refractory bladder conditions were identified. Their medical records were retrospectively evaluated for history, operative intervention, and programming visits. Events after implantation of the implantable pulse generator (IPG) unit were noted. The evaluation, troubleshooting, management, and resolution of events at the last follow-up visit were extracted. RESULTS: A total of 214 patients underwent sacral neuromodulation therapy at our institution. The mean patient age was 53.5 +/- 15.4 years. Of the 214 patients, 161 underwent IPG implantation during a mean follow-up period of 16 months (range 5 to 30). The second-stage explantation and revision rate was 10.5% and 16.1%, respectively. The indications for explantation were infection (8 of 17) and failure to maintain a response (9 of 17). Revisions were done for decreases in response with abnormal (12 of 26) or normal (5 of 26) impedance measurements, IPG site discomfort (4 of 26), draining sinus at the IPG site (4 of 26), and lead migration (1 of 26). Equalization of impedance measurements was the most commonly observed impedance abnormality. These were managed by drying fluid from the connection in 4 patients and lead change in the rest. CONCLUSIONS: After IPG implantation, a decline in response may occur. Although some were explanted, most were revised, with most of the revisions functional on follow-up. Familiarity with impedance evaluation and development of algorithms for postimplant management are essential for troubleshooting and maintenance of the device.

Electric Stimulation Therapy↗