PubMed Health⌕ Search

PubMed · 10198850

Phaco slice and separate.

Abstract

Phaco slice and separate retains the advantages of the chopping techniques of Nagahara, Koch, and Fukasaku but replaces chopping or snapping with slicing across the center of the phaco-tip-stabilized nucleus using a Nagahara chopper and then repositioning the chopper to optimally separate the divided lens halves. As the lens is rotated in the capsular bag, small pieces of the nuclear pie are sliced off, separated, emulsified, and aspirated. Emulsification and aspiration can alternatively be left until most or all the slices have been made. This technique works with a broader range of lens densities than other chopping techniques and uses no sculpting and very little phaco time. The phaco time required for this technique is relatively independent of nuclear density compared with a sculpting technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S A Arshinoff. 1999. Phaco slice and separate.. https://doi.org/10.1016/s0886-3350(99)80042-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Complications of endocapsular tension ring implantation in a child with Marfan's syndrome.

A 4-year-old boy with Marfan's syndrome had severe visual impairment after subluxation of the crystalline lens with bisection of the pupil. In the first eye, a capsular tension ring and an intraocular lens (IOL) were uneventfully placed in the capsular bag after phacoemulsification. During implantation of the endocapsular tension ring in the second eye, an inadvertent tear of the anterior capsule occurred, and the posterior chamber IOL was placed in the sulcus. In both eyes, severe lens epithelial proliferation with secondary IOL decentration developed postoperatively. Several surgical revisions were necessary to keep the IOL within the optical axis. In the eye with the sulcus-implanted IOL, the endocapsular tension ring was markedly decentered.

Capsulorhexis↗

Complete capsular bag distension syndrome.

After conventional extracapsular cataract extraction and in-the-bag intr aocular lens (IOL) implantation 3 years previously, the partially cut su perior one-third of the anterior capsulotomy flap resealed in the eye of a 55-year-old woman. With the integrity of the capsular bag restored, it distended fully; the IOL was in the center and milky fluid accumulated inside. A neodymium:YAG laser was used to drain the milky fluid and di srupt the opacified anterior and posterior capsules, restoring vision.

Capsulorhexis↗