PubMed Health⌕ Search

PubMed · 10219180

Unlocking orthodontic malocclusions: an interplay between form and function.

Abstract

It is possible to unlock dental malocclusions in a functional or mechanical manner, or in a combination of these two processes. Functional unlocking starts with an in-depth diagnosis of all aspects of a specific malocclusion including a recognition of those craniofacial dysfunctions that may be present. Craniofacial dysfunctions that may require treatment include those that involve the vegetative processes of breathing and swallowing and all aspects of cranial posture. This form of unlocking deals with the working environment of the oral cavity, that here, is also referred to as the oral functional matrix. Functional unlocking encompasses cognitive awareness training that involves patients in the treatment of their dysfunction. The early resolution of oral dysfunctions is not only an essential part of orthodontic treatment but it is also a vital component of the stability of the treatment results obtained. Mechanical unlocking, in contrast to functional unlocking, removes occlusal interferences that could interfere with the development and function of the entire stomatognathic system. Both functional and mechanical unlocking are often overlooked in orthodontic diagnosis and treatment planning. This article uses clinical examples, where possible, to illustrate how malocclusions may be unlocked to provide better and more stable treatment results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C F Gugino, I Dus. 1998. Unlocking orthodontic malocclusions: an interplay between form and function.. https://doi.org/10.1016/s1073-8746(98)80030-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Facial reconstruction using 3-D computer graphics.

Facial reconstruction using 3-D computer graphics is being used in our institute as a routine procedure in forensic cases as well as for skulls of historical and archaeological interest. Skull and facial data from living subjects is acquired using an optical laser scanning system. For the production of the reconstructed image, we employ facial reconstruction software which is constructed using the TCL/Tk scripting language, the latter making use of the C3D system. The computer image may then be exported to enable the production of a solid model, employing, for example, stereolithography. The image can also be modified within an identikit system which allows the addition of facial features as appropriate.

Cephalometry↗

Prospective study on the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms.

The introduction of digital X-ray techniques offered a variety of new possibilities for digital image enhancement and exposure reduction. In order to compare the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms 100 digital and 100 conventional lateral headfilms of patients attending our clinic were randomly selected. The digital cephalograms were obtained using storage phosphor plates in standard X-ray cassettes. All X-rays had been taken at 77 kV. For the digital images the mAs settings for conventional images minus 4 mAs were used. Two orthodontists traced each X-ray twice (21 reference points) at an interval of at least 1 week. The tracings were superimposed and the distances between the tracings of identical reference points were registered. The average reproducibility of cephalometric landmarks was significantly higher on the digitally obtained images, despite a reduction of radiation exposure of 23.7% in the digital images.

Cephalometry↗

[Computerised three-dimensional surgical simulator. Introduction and precision analysis of a new system].

Computed tomography (CT)-based anatomic three-dimensional (3D) models have become important tools in oral maxillofacial surgery. There are three problems involved in the precise transfer of the experience gained and the results of simulation surgery to the patient: (1) 3D models have no precise reference points; (2) it is difficult to measure translations three-dimensionally; and (3) exact transfer to the patient intraoperatively is impossible. We have introduced a new system which solves these problems. In the first step 3D dental arches are replaced by plaster models, using an occlusal device with three radioopaque hemispheres as reference. A computerised electromagnetic tracker makes 3D measurements possible during simulated surgery, and a newly developed transfer system with a neurosurgical head frame to provide stable anchorage is used for positioning during surgery. We present our experience with this system in 15 orthognathic patients undergoing bimaxillary surgery. With the 3D computerised simulation surgery and model operation transfer system (3D-COSMOS) the dental arches can be replaced with a mean accuracy of 0.03 mm. The 3D translations of jaw segments can be measured precisely (0.11 mm) and simultaneously at the osteotomy line and the teeth. The new jaw position is transferred mechanically with a precision of 0.05 mm. Operation time is prolonged only by 15 min.

Cephalometry↗