PubMed Health⌕ Search

PubMed · 10223490

Three-dimensional computer-simulated prostate models: lateral prostate biopsies increase the detection rate of prostate cancer.

Abstract

OBJECTIVES: Urologists routinely use the systematic sextant needle biopsy technique to detect prostate cancer. However, recent evidence suggests that this technique has a significant sampling error. We developed a novel three-dimensional (3D) computer-assisted prostate biopsy simulator based on whole-mounted step-sectioned radical prostatectomy specimens to compare the diagnostic accuracy of various prostate needle biopsy protocols. METHODS: We obtained digital images of 201 step-sectioned whole-mounted radical prostatectomy specimens. 3D computer simulation software was developed to accurately depict the anatomy of the prostate and all individual tumor foci. Additional peripheral devices were incorporated into the system to perform interactive prostate biopsies. We obtained 18 biopsies of each prostate model to determine the detection rates of various biopsy protocols. RESULTS: The 10- and 12-pattern biopsy protocols had a 99.0% detection rate; the traditional sextant biopsy protocol rate was only 72.6%. The 5-region biopsy protocol had a 90.5% detection rate and the 14-pattern, which includes all the biopsies used in the patterns above, only added 1 additional positive case (99.5%). Transitional zone and seminal vesicle biopsies did not result in a significantly increased detection rate when added to the patterns above. Only one positive model was obtained when the transitional zone biopsies were added. The lateral sextant pattern had a detection rate of 95.5%, and the 4-pattern lateral biopsy protocol had a 93.5% detection rate. CONCLUSIONS: Our results suggest that all the biopsy protocols that use laterally placed biopsies based on the 5-region anatomic model are superior to the routinely used sextant prostate biopsy pattern. Lateral biopsies in the mid and apical zones of the gland are the most important.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J J Bauer, J Zeng, J Weir, W Zhang, I A Sesterhenn, R R Connelly, S K Mun, J W Moul. 1999. Three-dimensional computer-simulated prostate models: lateral prostate biopsies increase the detection rate of prostate cancer.. https://doi.org/10.1016/s0090-4295(99)00068-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Targeting difficult accessible breast lesions: MRI-guided needle localization using a freehand technique in a 3.0 T closed bore magnet.

PURPOSE: To report the accuracy of magnetic resonance imaging (MRI)-guided needle localization for diagnosis of MRI detected suspicious breast lesions located in difficult accessible regions of the breast, using the freehand method in a 3.0 T closed bore magnet. MATERIALS AND METHODS: In five patients with five MRI-only breast lesions underwent MRI-guided needle localization for histopathologic evaluation of the lesions. All interventional procedures were performed in a 3.0 T MRI system with the patient in prone position and by using a dedicated phased array breast coil. MRI-guided needle localizations were performed by using a freehand technique. In our study, the high-resolution scan allowed preprocedural localization of all lesions without use of contrast enhancement. In all cases contrast-enhanced MRI was performed after insertion of the wire to confirm the tip of the wire in direct contact with the enhancing lesion. RESULTS: Needle localizations were performed in five patients. Histopathologic evaluation of tissue after surgery excision biopsy revealed one lymph node, three invasive ductal carcinoma and one ductal carcinoma in situ. Lesion size varied from 6 to 30 mm. Mean duration time was 25 min. No complications occurred during the intervention method. In the patient with the benign lesion control MRI of the breast after 6 months confirmed lesion removal. CONCLUSIONS: MRI-guided needle localization by using a freehand technique in a 3.0 T closed bore magnet is a safe and accurate method for diagnosis of difficult accessible breast lesions only visible on MRI.

Biopsy, Needle↗