Peripheral dose from a linear accelerator equipped with multileaf collimation.

Abstract

In radiation therapy, knowledge of the peripheral dose is important when anatomical structures with very low dose tolerances might be involved. Two of the major sources of peripheral dose, leakage from the linac head, and scatter from secondary collimators, depend strongly on the configuration of the linac head and therefore might be affected by the presence of a multileaf collimator (MLC). In this study, peripheral dose was measured at two depths and two field sizes for 6 and 18 MV photons from a linac with a MLC. The MLC was configured both with leaves fully retracted and with leaves positioned at the field edges defined by the secondary collimator jaws. Comparative measurements were also made for 6 MV photons from a linac without MLC. Peripheral dose was determined as a percentage of the central axis dose for the same energy, field size, and depth using diode detectors in solid phantom material. The data for the 6 MV without MLC agreed with those for the beam with MLC leaves retracted. For both energies at all depths and distances from the field edge, configuring the MLC leaves at the field edge yielded a reduction in peripheral dose of 6%-50% compared to MLC leaves fully retracted.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R L Stern. 1999. Peripheral dose from a linear accelerator equipped with multileaf collimation.. https://doi.org/10.1118/1.598557

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Microchip PCR.

Miniaturization of genetic tests has become an important goal. This review surveys the current progress towards the miniaturization of tests based on the polymerase chain reaction (PCR). It examines the different types of PCR microchip designs, fabrication methods,and the components of a microchip PCR device. It also discusses the problems attributable to surface chemistry of microchip components (inhibition of PCR), and the static and dynamic surface passivation strategies developed for the solution of these difficulties

Equipment Design↗

Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube.

OBJECTIVE: This study compared the recently introduced Microcuff endotracheal tube HVLP ICU featuring an ultrathin (7-microm) polyurethane cuff membrane with endotracheal tubes from different manufacturers regarding fluid leakage past the tube cuff. DESIGN: In vitro setup. MEASUREMENTS AND RESULTS: The following endotracheal tubes (ID 7.5 mm) were compared: Mallinckrodt HiLo, Microcuff HVLP ICU, Portex Profile Soft Seal, Rüsch Super Safety Clear, and Sheridan CF. A vertical PVC trachea model (ID 20 mm) was intubated, and cuffs were inflated to 10, 15, 20, 25, 30, and 60 cmH2O. Colored water (5 ml) was added to the top of the cuff. The amount of leaked fluid past the tube cuff within 5, 10, and 60 min was recorded. Experiments were performed four times using two examples of each tube brand. Fluid leakage past tube cuffs occurred in all conventional endotracheal tubes at cuff pressures from 10 to 60 cmH2O. In the Microcuff tube cuff pressure fluid leakage was observed within 10 min only at 10 cmH2O. Results with the Microcuff tube were significantly better than all other tube brands at cuff pressures of 10-30 cmH2O. CONCLUSIONS: Within the acceptable upper limit for tracheal cuff pressure (25-30 cmH2O) the Microcuff endotracheal tube was the only one of the tested tubes to prevent fluid leakage in our in vitro setup. In vivo studies are required to confirm these findings.

Equipment Design↗