Virtual endoscopy using perspective volume-rendered three-dimensional sonographic data: technique and clinical applications.

Abstract

OBJECTIVE: We present a technique for obtaining three-dimensional external and virtual endoscopy views of organs using perspective volume-rendered gray-scale and Doppler sonographic data, and we explore potential clinical applications in the carotid artery, the female pelvis, and the bladder. CONCLUSION: Using the proposed methods, radiologists will find it possible to create virtual endoscopy and external perspective views using sonographic data. The technique works well for revealing the interior of fluid-filled structures and cavities. However, expected improvements in computer performance and integration with existing sonographic equipment will be necessary for the technique to become practical in the clinical environment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E L Yuh, R B Jeffrey, R L Birdwell, B H Chen, S Napel. 1999. Virtual endoscopy using perspective volume-rendered three-dimensional sonographic data: technique and clinical applications.. https://doi.org/10.2214/ajr.172.5.10227488

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Visualization of fibrous cap thickness and rupture in human atherosclerotic carotid plaque in vivo with high-resolution magnetic resonance imaging.

BACKGROUND: The results of studies of advanced lesions of atherosclerosis suggest that the thickness of the fibrous cap that overlies the necrotic core distinguishes the stable lesion from one that is at high risk for rupture and thromboembolic events. We have developed a high-resolution MRI technique that can identify the fine structure of the lesion, including the fibrous cap, in vivo. The aim of the present study was to determine the agreement between in vivo MRI and lesion architecture as seen on histology and gross tissue examination to identify fibrous cap thickness and rupture. METHODS AND RESULTS: Twenty-two subjects who were scheduled for carotid endarterectomy underwent MRI with a 3-dimensional multiple overlapping thin slab angiography protocol. The appearance of the fibrous cap was categorized as (1) an intact, thick, (2) an intact, thin, or (3) a ruptured fibrous cap on MRI, gross, and histological sections. Thirty-six sites were available for comparison between MRI and histology. There was a high level of agreement between MRI and histological findings: 89% agreement, kappa (95% CI)=0.83 (0.67 to 1. 0), weighted kappa=0.87. Spearman's correlation coefficient was 0.88 (significant to the 0.01 level). CONCLUSIONS: These findings indicate that high-resolution MRI with a 3-dimensional multiple overlapping thin slab angiography protocol is capable of distinguishing intact, thick fibrous caps from intact thin and disrupted caps in atherosclerotic human carotid arteries in vivo. This noninvasive technique has the potential to permit studies that examine the relationship between fibrous cap changes and clinical outcome and to permit trials that evaluate therapy intended to "stabilize" the fibrous cap.

Carotid Arteries↗

[Variation of Doppler ultrasonography of carotid arteries].

The variation of ultrasound examination of the carotid arteries performed at two different hospitals was examined by retrospective analysis. Eighty-one patients were primarily examined by ultrasound at their local hospital on the suspicion of carotid stenosis. Following referral, they underwent a further scanning at the Dept. of Vascular Surgery, Rigshospitalet. Results for 143 carotid arteries were available for comparison. The overall agreement between the two examinations was only 59%. In nine of 40 (22%) cases an originally diagnosed minor stenosis was found to be significant and 3/19 (16%) with shown occlusion were found to be patent at the later examination. In order to draw clinical conclusions validation of each individual laboratory performing ultrasound examination of extracranial cervical arteries is necessary.

Carotid Arteries↗