PubMed Health⌕ Search

PubMed · 10228919

[Axillary lymph node excision].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Salmon, F Iovino. 1998. [Axillary lymph node excision].. https://pubmed.ncbi.nlm.nih.gov/10228919/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Chest wall irradiation with MLC-shaped photon and electron fields.

PURPOSE: To improve the treatment technique for chest wall irradiation, using the multileaf collimator (MLC) of the MM50 Racetrack Microtron to shape both photon and electron beams, and to check the dose delivery in the match-line region of these fields for the routine and improved technique. METHODS AND MATERIALS: Using diode and film phantom measurements, the optimal number of photon beam segments and their positions relative to the electron beam were determined. On phantoms, and during actual patient treatment using in vivo dosimetry, the dose homogeneity in the match-line region was determined for both the routine and improved techniques. RESULTS: Three photon beam segments (9-mm gap, perfect match, and 9-mm overlap) were used to match the electron beam, resulting in minimum-maximum dose values in the match-line region of 88-109%, compared to 80-115% for the routine technique (2 photon beam segments). During patient treatment, the average minimum and maximum dose values were 95% and 115%, respectively, compared to 78% and 127%, respectively, for the routine technique. The interfraction variation in dose delivery was reduced from 11.0% (1 SD) to 4.6% (1 SD). The actual treatment time was reduced from 10 to 4.5 min. CONCLUSION: Using the MLC of the MM50 to shape both photon and electron beams, an improved treatment technique for chest wall irradiation was developed, which is less labor intensive, faster, and yields a more homogeneous, and better reproducible dose delivery.

Axilla↗

CT-targeted irradiation of the breast and internal mammary lymph nodes using a 5-field technique.

PURPOSE: To develop an effective and resource-efficient radiotherapy technique to treat the breast and regional nodes, including the ipsilateral internal mammary nodes. METHODS AND MATERIALS: Eighty female patients who underwent MRI scans for a variety of indications had coronal, T1-weighted images of the chest performed to determine the position of the internal mammary chain (IMC). Based on these results, a 5-field treatment technique was developed that would include the breast, supraclavicular fossa, and ipsilateral IMC, while maintaining a low dose to the heart, lungs, and contralateral breast. This technique was implemented in a cohort of 13 patients. RESULTS: The lateral position of the right and left IMC were measured in three cephalo-caudad positions: at the clavicular heads, upper manubrium, and midsternum (at the 2nd/3rd rib interspace). The mean lateral separation between the right and left IMC chains at each level (and 95% confidence interval) at each level were 5.8 cm (4.67-7.00), 5.6 cm (4.49-6.73), and 5.9 cm (4.66-7.19), respectively. Treatment was delivered to 13 patients using a 5-field technique, with tangential photon fields for the breast, anterior and posterior supraclavicular/axillary field, and a matching anterior electron field. Three-dimensional treatment planning of a representative case confirmed adequate coverage of the planning target volume (PTV). The median dose to the whole heart was 10 Gy, and 20% of the ipsilateral lung received more than 20 Gy. Seven of the 13 patients treated experienced moist desquamation at the junction of the electron field and breast tangents, and 1 patient had persistent ulceration at 3 months' follow-up. CONCLUSION: The 5-field technique described in this paper provides good coverage to the breast and regional nodes with acceptable toxicity, and without requiring three-dimensional treatment planning or intensity-modulated radiotherapy techniques.

Axilla↗