PubMed Health⌕ Search

PubMed · 10253004

Implementing a community-based cancer control program.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H G Brown. 1981. Implementing a community-based cancer control program.. https://doi.org/10.1097/00003727-198111000-00004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

NASA/American Cancer Society High-Resolution Flow Cytometry Project - III. Multiparametric analysis of DNA content and electronic nuclear volume in human solid tumors.

BACKGROUND: The NASA/American Cancer Society (ACS) flow cytometer can simultaneously measure electronic nuclear volume (ENV) and DNA content of nuclei. The preceding articles in this volume ("NASA/American Cancer Society High-Resolution Flow Cytometer Project-I") described the schematics, performance, and procedures used for the preparation of nuclei for analysis on this unit. In the present article, we describe the analysis of selected human tumors using the ratio of ENV/DNA content (nuclear packing efficiency [NPE]). METHODS: Tumor specimens (frozen) were minced with scalpels and stained with 1-10 microg/ml of 4',6-diamidino-2-phenylindole (DAPI) dihydrochloride at pH 6.0-7.2. Trout erythrocytes were used as internal standards. Data on ENV and DNA content were collected in list mode files. Propidium iodide-stained nuclei, analyzed on a Coulter XL cytometer, were used for comparison. RESULTS: Simultaneous measurement of ENV and DNA makes it possible to discriminate between hypodiploid or hyperdiploid tumor cells, as well as to differentiate between near-diploid aneuploid and diploid cells on the basis of their increased ENV. The NPE ratio is a valuable parameter for the detection of small quantities of tumor cells, separating overlapping diploid and aneuploid populations for cell cycle analysis and characterizing the level of differentiation in some tumors. CONCLUSION: NPE analysis provides unique measuring capabilities for the study of human solid tumors by flow cytometry.

American Cancer Society↗

NASA/American Cancer Society High-Resolution Flow Cytometry Project-I.

BACKGROUND: The NASA/American Cancer Society (ACS) flow cytometer can simultaneously analyze the electronic nuclear volume (ENV) and DNA content of cells. This study describes the schematics, resolution, reproducibility, and sensitivity of biological standards analyzed on this unit. METHODS: Calibrated beads and biological standards (lymphocytes, trout erythrocytes [TRBC], calf thymocytes, and tumor cells) were analyzed for ENV versus DNA content. Parallel data (forward scatter versus DNA) from a conventional flow cytometer were obtained. RESULTS: ENV linearity studies yielded an R value of 0.999. TRBC had a coefficient of variation (CV) of 1.18 +/- 0.13. DNA indexes as low as 1.02 were detectable. DNA content of lymphocytes from 42 females was 1.9% greater than that for 60 males, with a noninstrumental variability in total DNA content of 0.5%. The ENV/DNA ratio was constant in 15 normal human tissue samples, but differed in the four animal species tested. The ENV/DNA ratio for a hypodiploid breast carcinoma was 2.3 times greater than that for normal breast tissue. CONCLUSIONS: The high-resolution ENV versus DNA analyses are highly reliable, sensitive, and can be used for the detection of near-diploid tumor cells that are difficult to identify with conventional cytometers. ENV/DNA ratio may be a useful parameter for detection of aneuploid populations.

American Cancer Society↗

NASA/American Cancer Society High-Resolution Flow Cytometry Project - II. Effect of pH and DAPI concentration on dual parametric analysis of DNA/DAPI fluorescence and electronic nuclear volume.

BACKGROUND: In the present paper, we describe the effect of 4', 6-diamidino-2-phenylindole (DAPI) dihydrochloride concentration and pH on the resolution of DNA distribution histograms generated by dual-parametric simultaneous analysis of DNA content and electronic nuclear volume (ENV). METHODS: Nuclei from tissue culture cell lines and frozen human solid tumors were isolated in nuclear isolation media containing different concentrations of DAPI, at various pH levels, and analyzed on a NASA/American Cancer Society (ACS) flow cytometer. Samples stained with propidium iodide/hypotonic citrate and analyzed in a Coulter XL flow cytometer were used for comparison. RESULTS: Nuclei stained with DAPI concentration of 1-3 microg/ml, pH 6.0, gave the best resolution for the detection of the near-diploid and near-tetraploid populations. Simultaneous use of ENV and DAPI/DNA fluorescence under these conditions identified subpopulations that otherwise could not be detected by DNA analysis alone. CONCLUSIONS: Staining at 1-3 microg/ml DAPI, pH 6.0, was optimal for the detection of aneuploid populations, especially the near-diploid and/or near-tetraploid populations in human tumors.

American Cancer Society↗