PubMed HealthSearch

PubMed · 10271948

Electrosurgery--macro vs micro.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Hausner. 1985. Electrosurgery--macro vs micro.. https://pubmed.ncbi.nlm.nih.gov/10271948/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Artefact cancellation in motor-sensory evoked potentials: two approaches using adaptive filtration and exponential approximation.

Adaptive filtering for artefact cancellation in motor-sensory evoked potentials using signals obtained by subtraction methods (double-stimulus, off-nerve and subthreshold) is proposed. This is advantageous as inherent non-linear distortions can be overcome in an easier way by adaptive filtering. Efficiency is assessed with reference signals synthesised by varying the shape and reducing the amplitude of a 'pure' evoked potential in the range from 10% to 50%. The experiments show virtually identical shapes of the 'pure' and the filtered signal. The time shift between them is insignificant if a causal filter and small number of Widrow coefficients, e.g. N = 8, are used. Further, two-exponential artefact approximation is applied with subsequent direct subtraction from the contaminated signal by a specially designed PC-controlled system for data acquisition and processing. For a fast procedure convergence, one-parametric optimisation of the time-constant tau is used, starting with tau = 0.5 ms. The results obtained with artefact-corrupted evoked potentials from several subjects prove the efficiency of the approach. It has the substantial advantage of avoiding the need for reference signals. Both methods have advantages compared with other known software techniques.

Electronics, Medical

A fast recursive-least-squares adaptive notch filter and its applications to biomedical signals.

A fast recursive-least-squares (FRLS) adaptive notch filter (ANF) for cancellation of sinusoidal interference from recorded biomedical signals is investigated. The FRLS ANF is derived by making an approximation to the conventional recursive-least-squares (RLS) ANF for computation economy. It outperforms the commonly adopted least-mean-squares (LMS) ANF, demonstrating a rapid and bandwidth-insensitive initial convergence. A novel application of the FRLS ANF is for the elimination of the tonal artefact in distortion product otoacoustic emission (DPOAE) signals.

Electronics, Medical

Apparatus to measure simultaneously 14 isometric leg joint moments. Part 2: Multi-moment chair system.

An apparatus has been developed that measures isometrically the 14 lower limb joint moments corresponding to the degrees of freedom of the hips, knees and ankles. This is the second of two papers describing the development of the multi-moment chair system (MMCS). It presents the overall design and changes that were implemented to compensate for problems. These were primarily to improve the accuracy of hip joint moments; a compromise between accuracy and practicalities, because of force-moment responses being measured at the ankles. All joint moment errors have been calculated to be of the order of a few newton metres. Since these represent errors of less than 10% when considering peak joint moment responses, this is considered sufficiently accurate for the proposed application. The MMCS is being used in a programme to investigate the restoration of lower limb functions, principally standing, in paraplegics by electrical stimulation of the lumbosacral anterior roots.

Electronics, Medical