PubMed Health⌕ Search

PubMed · 10300776

Evaluation readiness: improved evaluation planning using a data inventory framework.

Abstract

Factors intrinsic to many programs, such as ambiguously stated objectives, inadequately defined performance measures, and incomplete or unreliable databases, often conspire to limit the evaluability of these programs. Current evaluation planning approaches are somewhat constrained in their ability to overcome these obstacles and to achieve full preparedness for evaluation. In this paper, the concept of evaluation readiness is introduced as a complement to other evaluation planning approaches, most notably that of evaluability assessment. The basic products of evaluation readiness--the formal program definition and the data inventory framework--are described, along with a guide for assuring more timely and appropriate evaluation response capability to support the decision making needs of program managers. The utility of evaluation readiness for program planning, as well as for effective management, is also discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A B Cohen, K C Hall, D R Cohodes. 1985. Evaluation readiness: improved evaluation planning using a data inventory framework.. https://doi.org/10.1016/0149-7189(85)90027-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Application of solvent microextraction to the analysis of nitroaromatic explosives in water samples.

The application of solvent microextraction to the analysis of nitroaromatic explosives is presented. Extraction of 11 nitroaromatics was achieved by suspending 1 microl of organic solvent to the tip of a microsyringe in a stirred aqueous solution. Parameters such as extraction solvent, stirring rate, salt concentration and sampling time were studied and optimized. The limits of detection using bench-top quadrupole mass spectrometry and short extraction times (15 min) were found to be between 0.08 and 1.3 microg/l and the relative standard deviations ranged between 4.3 and 9.8%. Although precision and accuracy of quantification of the method are still needed, solvent microextraction proved to be a fast, simple and inexpensive tool for preconcentration and matrix isolation of nitroaromatics on a microscale.

Evaluation Studies as Topic↗

Interventions to improve physicians' well-being and patient care: a commentary.

Dr. Firth-Cozens begins her paper by reviewing a broad range of research related to physicians' stress, depression, and alcoholism (Firth-Cozens, 2001, Social Science and Medicine, 52, 215-222). She then argues that these psychological problems have a negative impact on patient care and describes the possible causes of these problems. Finally, she proposes a system of organizational and individual interventions to address these problems. Before accepting her conclusions and proposed system of interventions, an important issue should be considered. Is physicians' well-being an important goal in and of itself, or do we need strong evidence that physician stress, depression, and alcoholism lead to poor patient care and outcomes?

Evaluation Studies as Topic↗

Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography.

PURPOSE: To evaluate the imaging characteristics of an amorphous silicon flat-panel detector (FPD) for digital chest radiography. MATERIALS AND METHODS: The 41 x 41-cm digital FPD is constructed on a single monolithic glass substrate with a structured cesium iodide scintillator layer and an amorphous silicon thin-film transistor array for image readout. Basic imaging characteristics of the FPD and associated image processing system were assessed on acquired images, including linearity, repeatability, uniformity of response, modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), contrast sensitivity, and scatter content. Results with the FPD system were compared to those with a storage phosphor computed radiography (CR) system. RESULTS: Images obtained with the FPD demonstrated excellent uniformity, repeatability, and linearity, as well as MTF and DQE that were superior to those with the storage phosphor CR system. The contrast and scatter content of images acquired with the FPD were equivalent to those acquired with the storage phosphor system. CONCLUSION: The FPD provides radiographic images with excellent inherent physical image quality.

Evaluation Studies as Topic↗