Quality control in the pulmonary function laboratory.

Abstract

The addition of computers to pulmonary function laboratories has reduced quality-control problems. After standards for a test have been selected, the computer can enforce adherence to them. The computer can be programmed to perform periodic calibration checks and other self-diagnostic procedures to ensure that instrumentation and human errors have not gone undetected. The computer can be used to verify that reference values are within acceptable limits and that results for a particular patient are at least internally consistent. The computer greatly reduces the number of measurements and calculations that must be done by hand and therefore improves laboratory efficiency and reduces the probability of human error. Quality-control samples can be processed more frequently with the use of a computer because this task consumes less time than when done by laboratory personnel. Some disadvantages of quality control that have appeared since the introduction of the computer are the potential for undetected failure of computer hardware and software, a risk that has increased with the increase in software complexity, and the potential for the loss of large amounts of information because of its being stored on a single digital medium. To effect quality control in the pulmonary function laboratory one should (1) ensure that procedures and software conform to standards, (2) follow routine calibration-check procedures, (3) check test results for internal consistency and for consistency with other test results, (4) conduct periodic testing of a quality-control subject or reference sample, (5) continually evaluate software performance, (6) carefully evaluate changes in instrumentation and software, and (7) maintain duplicate copies of data on different types of mass storage media.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J L Hankinson. 1982. Quality control in the pulmonary function laboratory.. https://pubmed.ncbi.nlm.nih.gov/10315285/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Hyaluronic acid and chondroitin sulfate unsaturated disaccharides analysis by high-performance liquid chromatography and fluorimetric detection with dansylhydrazine.

A system capable of resolving all the known unsaturated nonsulfated, mono- and disulfated disaccharides derived from chondroitin sulfate samples, dermatan sulfate, and hyaluronic acid after their derivatization with dansylhydrazine and separation by HPLC and fluorimetric detection is reported. This method was found superior to others in that unsaturated disaccharides can be separated with good resolution in about 50 min in an isocratic solvent with a sensitivity greater than about 50 pmol (approx 20-30 ng) and linearity from 50 to 500 pmol. The system was applied to the analysis of various chondroitin sulfate samples, including highly sulfated species and dermatan sulfate, and also to a defructosylated polysaccharide with a chondroitin backbone purified from Escherichia coli U1-41. Excellent agreement was obtained with traditional compositional analysis performed by anion-exchange HPLC separation and UV absorption at 230 nm.

Calibration

Biological quality control for exercise testing.

BACKGROUND: A study was undertaken to evaluate the use of a biological quality control programme for a computer controlled, breath-by-breath exercise test system over a 2.5 year period. METHODS: One healthy volunteer performed a regular progressive treadmill test with breath-by-breath measurements of oxygen uptake (VO(2)), carbon dioxide output (VCO(2)), ventilation (VE), and the ECG heart rate (HR). Following a familiarisation period, five consecutive tests were performed and the measurements at peak exercise were averaged to give baseline values. All tests were compared with these values. RESULTS: A total of 35 tests were recorded. The within subject standard deviation for measurements at peak exercise were 52 ml/min for VO(2), 74 ml/min for VCO(2), 3.1 l/min for VE, and 3 beats/min for HR. The mean (SE) percentage variation in measurements at peak exercise compared with the baseline values was +0.37 (0.30)% for VO(2), -0.10 (0.39)% for VCO(2), -0.88 (0.52)% for VE, and +1.2 (0.26)% for HR. The variability present in measurements made during high and moderate intensity exercise (73% VO(2)peak) was not significantly different (p>0.05). During the study period the quality control detected a fault on the oxygen analyser which was not apparent from the automatic calibration. CONCLUSIONS: Regular quality control using a healthy volunteer allows all components of the breath-by-breath system to be checked simultaneously and in a manner which is consistent with its clinical use. This practice can highlight faults not detected by automatic calibration.

Calibration

First attempt of odorant quantitation using gas chromatography-olfactometry.

An aroma compound was quantitated for the first time by GC-olfactometry (GC-O) on the basis of the detection frequency of odorants by a panel of 8-12 persons. The method was previously optimized regarding the coincidence of olfactometric peak apexes and the repeatability of peak height and area over 4 months. The number of required calibration points and the confidence interval of the curve were investigated. This technique was then tested by quantifying a model solution of 1-octen-3-one. The standard addition method was found to be unsuitable in this context, but external calibration gave excellent results in the ppt range. GC-O was then challenged using one of the most sensitive and selective methods, GC/MS, to quantitate 1-octen-3-one in coffee, a complex aroma. Results showed performances comparable to GC/MS/MS for this odorant, or even better as the latter required 75-500 times more sample to perform the quantitation. However, at such a low concentration, overestimation cannot be excluded with either technique because of possible coelution of odorants or isobaric ions, respectively. These results show that GC-olfactometry can compete with the most sensitive and selective techniques, such as MS, for determination of extremely intense odorants, because little sample preparation is required and there is no need for the synthesis of labeled compounds.

Calibration