PubMed Health⌕ Search

PubMed · 10326733

Damage modes in dental layer structures.

Abstract

Natural teeth (enamel/dentin) and most restorations are essentially layered structures. This study examines the hypothesis that coating thickness and coating/substrate mismatch are key factors in the determination of contact-induced damage in clinically relevant bilayer composites. Accordingly, we study crack patterns in two model "coating/substrate" bilayer systems conceived to simulate crown and tooth structures, at opposite extremes of elastic/plastic mismatch: porcelain on glass-infiltrated alumina ("soft/hard"); and glass-ceramic on resin composite ("hard/soft"). Hertzian contacts are used to investigate the evolution of fracture damage in the coating layers, as functions of contact load and coating thickness. The crack patterns differ radically in the two bilayer systems: In the porcelain coatings, cone cracks initiate at the coating top surface; in the glass-ceramic coatings, cone cracks again initiate at the top surface, but additional, upward-extending transverse cracks initiate at the internal coating/substrate interface, with the latter dominant. The substrate is thereby shown to have a profound influence on the damage evolution to ultimate failure in the bilayer systems. However, the cracks are highly stabilized in both systems, with wide ranges between the loads to initiate first cracking and to cause final failure, implying damage-tolerant structures. Finite element modeling is used to evaluate the tensile stresses responsible for the different crack types. The clinical relevance of these observations is considered.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y G Jung, S Wuttiphan, I M Peterson, B R Lawn. 1999. Damage modes in dental layer structures.. https://doi.org/10.1177/00220345990780040901

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrolytic A12O3 coating on co-cr-mo implant alloys of hip prosthesis.

The ceramic films over metallic implant surfaces have the potential to improve implant performance with respect to implant fixation, wear, or corrosion. In this study, the electrolytic Al2O3 coatings on F-1537 Co-Cr-Mo alloy were conducted in an aqueous solution of Al(NO3)3. Through the cycle polarization test in Hank's solution, it was found that the corrosion potential and protection potential of the alumina-coated were higher than that of the uncoated, and the corrosion current density was lower. The phase transformation of A12O3 film on Co-Cr-Mo alloy annealed at 800 K revealed todlite (5Al2O3 . H2O) and thetaAl2O3 (113) preferred orientation for 20 min, and thetaAl2O3 (200) preferred orientation with eta phase for 80 min. Scanning electron microscopy/energy dispersive spectroscopy observations after the scratch tests showed that the adhesion of the alumina films on Co-Cr-Mo alloy can load a stress over the yield strength (450 MPa) of Co-Cr-Mo alloy. The wear loss of ultra-high molecular-weight polyethylene to the Al2O3-coated specimen was eight times less than that to the uncoated. It is concluded that such Al2O3-coated films on Co-Cr-Mo implant alloy exhibit excellent quality in corrosion, adhesion, and wear for the application of hip prosthesis.

Aluminum Oxide↗

An on-belt elemental analyser for the cement industry.

On-line control of raw mill feed composition is a key factor in the improved control of cement plants. A new and improved on-conveyor belt elemental analyser for cement raw mill feed based on neutron inelastic scatter and capture techniques has been developed and tested successfully in Adelaide Brighton's Birkenhead cement plant on highly segregated material with a depth range of 100 to 180 mm. Dynamic tests in the plant have shown analyser RMS total errors of 0.49, 0.52, 0.38 and 0.23 wt% (on a loss free basis) for CaO, SiO2, Al2O3 and Fe2O3 respectively, when 10-minute counting periods are used.

Aluminum Oxide↗