PubMed Health⌕ Search

PubMed · 10332854

Multiple region MRI.

Abstract

Traditional Fourier MR imaging (FT MRI) utilizes the Whittaker-Kotel'nikov-Shannon (WKS) sampling theorem. This theorem specifies the spatial frequency components which need to be measured to reconstruct an image with a known field of view (FOV). In this paper, we generalize this result in order to find the optimal k-space sampling for images that vanish except in multiple, possibly non-adjacent regions within the FOV. This provides the basis for "multiple region MRI" (mrMRI), a method of producing such images from a traction of the k-space samples required by the WKS theorem. Image reconstruction does not suffer from noise amplification and can be performed rapidly with fast Fourier transforms, just as in conventional FT MRI. The mrMRI method can also be used to reconstruct images that have low spatial-frequency components throughout the entire FOV and high spatial frequencies (i.e. edges) confined to multiple small regions. The greater efficiency of mrMRI sampling can be parlayed into increased temporal or spatial resolution whenever the imaged objects have signal or "edge" intensity confined to multiple small portions of the FOV. Possible areas of application include MR angiography (MRA), interventional MRI, functional MRI, and spectroscopic MRI. The technique is demonstrated by using it to acquire Gd-enhanced first-pass 3D MRA images of the carotid arteries without the use of bolus-timing techniques.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S K Nagle, D N Levin. 1999. Multiple region MRI.. https://doi.org/10.1002/(sici)1522-2594(199904)41%3A4%3C774%3A%3Aaid-mrm17%3E3.0.co%3B2-d

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Accumulation of ultrasmall superparamagnetic particles of iron oxide in human atherosclerotic plaques can be detected by in vivo magnetic resonance imaging.

BACKGROUND: One of the features of high-risk atherosclerotic plaques is a preponderance of macrophages. Experimental studies with hyperlipidemic rabbits have shown that ultrasmall superparamagnetic particles of iron oxide (USPIOs) accumulate in plaques with a high macrophage content and that this induces magnetic resonance (MR) signal changes. The purpose of our study was to investigate whether USPIO-enhanced MRI can also be used for in vivo detection of macrophages in human plaques. METHODS AND RESULTS: MRI was performed on 11 symptomatic patients scheduled for carotid endarterectomy before and 24 (n=11) and 72 (n=5) hours after administration of USPIOs (Sinerem) at a dose of 2.6 mg Fe/kg. Histological and electron microscopical analyses of the plaques showed USPIOs primarily in macrophages within the plaques in 10 of 11 patients. Histological analysis showed USPIOs in 27 of 36 (75%) of the ruptured and rupture-prone lesions and 1 of 14 (7%) of the stable lesions. Of the patients with USPIO uptake, signal changes in the post-USPIO MRI were observed by 2 observers in the vessel wall in 67 of 123 (54%) and 19 of 55 (35%) quadrants of the T2*-weighted MR images acquired after 24 and 72 hours, respectively. For those quadrants with changes, there was a significant signal decrease of 24% (95% CI, 33% to 15%) in regions of interest in the images acquired after 24 hours, whereas no significant signal change was found after 72 hours. CONCLUSIONS: Accumulation of USPIOs in macrophages in predominantly ruptured and rupture-prone human atherosclerotic lesions caused signal decreases in the in vivo MR images.

Carotid Arteries↗

MRI measurement of time-resolved wall shear stress vectors in a carotid bifurcation model, and comparison with CFD predictions.

PURPOSE: To study pulsatile fluid flow in a physiologically realistic model of the human carotid bifurcation, and to derive wall shear stress (WSS) vectors. MATERIALS AND METHODS: WSS vectors were calculated from time-resolved 3D phase-contrast (PC) MRI measurements of the velocity field. The technique was first validated with sinusoidal flow in a straight tube, and then used in a model of a healthy human carotid bifurcation. Velocity measurements in the inflow and outflow regions were also used as boundary conditions for computational fluid dynamics (CFD) calculations of WSS, which were compared with those derived from MRI alone. RESULTS: The straight tube measurements gave WSS results that were within 15% of the theoretical value. WSS results for the phantom showed the main features expected from fluid dynamics, notably the low values in the bulb region of the internal carotid artery, with a return to ordered flow further downstream. MRI was not able to detect the high WSS values along the divider wall that were predicted by the CFD model. Otherwise, there was good general agreement between MRI and CFD. CONCLUSION: This is the first report of time-resolved WSS vectors estimated from 3D-MRI data. The technique worked well except in regions of disturbed flow, where the combination with CFD modeling is clearly advantageous.

Carotid Arteries↗