Optimization of a contrast-detail-based method for electronic image display quality evaluation.

Abstract

The authors previously reported a general technique based on contrast-detail methods to provide an overall quantitative evaluation of electronic image display quality. The figure-of-merit reflecting overall display quality is called maximum threshold contrast or MTC. In this work we have optimized the MTC technique through improvements in both the test images and the figure-of-merit computation. The test images were altered to match the average luminance with that observed for clinical computed radiographic images. The figure-of-merit calculation was altered to allow for contrast-detail data with slopes not equal to -1. Preliminary experiments also were conducted to demonstrate the response of the MTC measurements to increased noise in the displayed image. MTC measurements were obtained from five observers using the improved test images displayed with maximum monitor luminance settings of 30-, 50-, and 70-ft-Lamberts. Similar measurements were obtained from two observers using test images altered by the addition of a low level of image noise. The noise-free MTC and MTC difference measurements exhibited standard deviations of 0.77 and 1.55, respectively. This indicates good measurement precision, comparable or superior to that observed using the earlier MTC technique. No statistically significant image quality differences versus maximum monitor luminance were seen. The noise-added MTC measurements were greater than the noise-free values by an average of 4.08 pixel values, and this difference was statistically significant. This response is qualitatively correct, and is judged to indicate good sensitivity of the MTC measurement to increased noise levels.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N J Hangiandreou, K A Fetterly, J P Felmlee. 1999. Optimization of a contrast-detail-based method for electronic image display quality evaluation.. https://doi.org/10.1007/bf03168844

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Practical assessment of the display performance of radiology workstations.

The performance of 14 primary clinical display monitor workstations in use in the Radiology Department of a large acute NHS Trust was assessed using the methods and guidelines described by the American Association of Physicists in Medicine Task Group 18. Tests undertaken included the measurement of ambient light, display uniformity, luminance ratio, luminance response, maximum luminance and spatial resolution. Four display monitors failed to meet at least one of the test's guideline tolerances. In addition a number of display monitors were found to be operating at settings that might reduce their useful life span. These devices were either replaced or recalibrated by the installers, or were subject to local adjustment to ensure applicable standards were met. Consequently the study suggests that quality assurance testing of display monitors used for image reporting is necessary and valuable to ensure that images are viewed at an appropriate standard.

Computer Terminals↗