PubMed Health⌕ Search

PubMed · 10367279

Mutation detection by stacking hybridization on genosensor arrays.

Abstract

A new strategy for analysis of point mutations using oligonucleotide array (genosensor) hybridization was investigated. In the new approach, a single-stranded target strand is preannealed with a labeled "stacking oligonucleotide," and then the partially duplex labeled target molecule is hybridized to an array of glass-tethered oligonucleotide probes, targeted to the region on the target immediately adjacent to the stacking oligomer. In this configuration, the base-stacking interactions between the "capture probe" and the contiguously stacking oligomer stabilize the binding of the target molecule to its complementary probe on the genosensor array. The temperature of hybridization can be adjusted so that the target molecule will bind to the glass-tethered probe only in the presence of the stacking oligomer, and a single mismatch at or near the terminal position ol the capture probe disrupts the stacking interactions and thereby eliminates or greatly reduces the hybridization. This stacking hybridization approach was investigated using a collection of synthetic targets, probes, and stacking oligonucleotides, which permitted identification of conditions for optimal base mismatch discrimination. The oligonucleotide probes were tethered to the glass using a simple, improved attachment chemistry in which a 3'-aminopropanol function introduced into the probe during chemical synthesis binds covalently to silanol groups on clean, underivatized glass. "Operating parameters" examined in the stacking hybridization system included length of capture probe, position, type and number of mismatches between the probe and the target, temperature of hybridization and length of washing, and the presence of terminal phosphate group in the probe, at its junction with the stacking oligomer. The results suggest that in the stacking hybridization configuration: 1. Optimal mismatch discrimination with 9-mer probes occurs at 45 degrees C, after which little or no improvement in mispair rejection occurred on lengthy continued washing at 45 degrees C. 2. At 25 degrees C optimal mismatch discrimination occurred with 7- or 8-mer probes, or with 9-mer probes containing an additional internal mismatch. 3. The presence of a phosphate group on the 5'-end of the glass-tethered probe had no general effect on mismatch discrimination, but influenced the relative stability of different mismatches in the sequence context studied. These results provide a motivation for continued development of the stacking hybridization technique for nucleic acid sequence analysis. This approach offers several advantages over the traditional allele-specific oligonucleotide hybridization technique, and is distinct from the contiguous stacking hybridization sitrategy that the Mirzabekov laboratory has introduced (Yershov et al. (1996) Proc. Natl. Acad. Sci. USA 93, 4913-4918; Parinov et al. (1996) Nucleic Acids Res. 24, 2998-3004).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Maldonado-Rodriguez, M Espinosa-Lara, P Loyola-Abitia, W G Beattie, K L Beattie. 1999. Mutation detection by stacking hybridization on genosensor arrays.. https://doi.org/10.1007/bf02789173

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Identifying novel transcripts and novel genes in the human genome by using novel SAGE tags.

The number of genes in the human genome is still a controversial issue. Whereas most of the genes in the human genome are said to have been physically or computationally identified, many short cDNA sequences identified as tags by use of serial analysis of gene expression (SAGE) do not match these genes. By performing experimental verification of more than 1,000 SAGE tags and analyzing 4,285,923 SAGE tags of human origin in the current SAGE database, we examined the nature of the unmatched SAGE tags. Our study shows that most of the unmatched SAGE tags are truly novel SAGE tags that originated from novel transcripts not yet identified in the human genome, including alternatively spliced transcripts from known genes and potential novel genes. Our study indicates that by using novel SAGE tags as probes, we should be able to identify efficiently many novel transcripts/novel genes in the human genome that are difficult to identify by conventional methods.

Base Pair Mismatch↗

Tumorigenesis: RAF/RAS oncogenes and mismatch-repair status.

Genes of the RAF family encode kinases that are regulated by Ras and mediate cellular responses to growth signals. Activating mutations in one RAF gene, BRAF, have been found in a high proportion of melanomas and in a small fraction of other cancers. Here we show that BRAF mutations in colorectal cancers occur only in tumours that do not carry mutations in a RAS gene known as KRAS, and that BRAF mutation is linked to the proficiency of these tumours in repairing mismatched bases in DNA. Our results not only provide genetic support for the idea that mutations in BRAF and KRAS exert equivalent effects in tumorigenesis, but also emphasize the role of repair processes in establishing the mutation spectra that underpin human cancer.

Base Pair Mismatch↗

Misalignment-mediated DNA polymerase beta mutations: comparison of microsatellite and frame-shift error rates using a forward mutation assay.

Mutations arising in microsatellite DNA are associated with neurological diseases and cancer. To elucidate the molecular basis of microsatellite mutation, we have determined the in vitro polymerase error frequencies at microsatellite sequences representative of those found in the human genome: [GT/CA](10), [TC/AG](11), and [TTCC/AAGG](9). DNA templates contained the microsatellites inserted in-frame into the 5' region of the herpes simplex virus thymidine kinase (HSV-tk) gene. Polymerase beta (polbeta) error frequencies were quantitated in microsatellite sequences, relative to frame-shift error frequencies in coding sequences, from the same DNA synthesis reaction. The polbeta error frequencies within the dinucleotide sequences were (2-9) x 10(-3), 14-72-fold higher than the ssDNA template frequencies. The polbeta error frequencies within the tetranucleotide sequences were (4-6) x 10(-3), a 4-13-fold increase over background. Strand biases were observed for the [TC/AG](11) and [TTCC/AAGG](9) alleles, in which more errors were produced when the purine strand served as a template. Mutations within each microsatellite included noncanonical base substitution events and single nucleotide deletions as well as the expected unit length changes. An exponential relationship was observed between the polymerase error frequency per site and both the number of repetitive units and total length of the allele. Our observations are consistent with the strand slippage model of microsatellite mutagenesis and demonstrate that DNA sequence and/or structural differences result in mutational strand biases. To our knowledge, this is the first direct quantitation of DNA polymerase errors in vitro using template microsatellite sequences.

Base Pair Mismatch↗